7.9.9 Code PROFIBUS-Interface
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
TR-Mode Position
X TR-Mode Po Rpm. X
not supported!
not supported!
Defines the output code for the PROFIBUS interface.
7.9.10 Limit switch lower and upper limit
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
TR-Mode Position
X TR-Mode Po Rpm. X
not supported!
not supported!
Is the status switched on (see commissioning function page 111) the measuring
system can inform the master via a bit whether the actual value is within the limits.
Limit switch bit = 0
Process-actual value
lower limit switch or
Process-actual value
upper limit switch
Limit switch bit = 1
Process-actual value < lower limit switch or
Process-actual value > upper limit switch
The inputs depend on the total measuring length in increments.
lower limit
0
upper limit
programmed total measuring length in increments
– 1,
within
33 554 432
default Lower limit switch
0
default Upper limit switch
4096
7.9.11 Velocity [1/x rpm]
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
TR-Mode Position
TR-Mode Po Rpm. X
not supported!
not supported!
not supported!
With this parameter, the specified rotational speed can be scaled in arbitrary steps
between 1/1 and 1/100 revs./min.