TU600-x
Short Guide TU600-x v0.2, January 2020, ©Trackunit 2020
14
Fuse
Recommended fuse holders and fuses for installation up to 48V supply
voltages (can be ordered at Trackunit A/S):
a. Supply voltage 12V/24V (Max 30A)
i. ATO blade fuses (Max 32V/1A) used with Littelfuse FHAC0002SXJ fuse
holder (standard).
ii. ATP blade fuse (Max 32V/1A - ATO style) used with TaiTek FH-
006WR-12R-12-U fuse holder (standard).
b. Supply voltage 12V - 48V (Max 30A)
i. FKS blade fuse (Max 80V/3A - ATO style) used with Littelfuse FH2 fuse
holder (recommended).
Machinery
The TU600 product complies with the essential requirements of the Directive
2006/42/EC and EU regulation 167/2013 when integrated as intended:
I)
ISO 13766-1 Earth-moving machinery and construction machinery
II)
EN/ISO 14982 Agricultural and forestry machines.
III)
EN 12895 Industrial trucks – Electromagnetic compatibility.
IV) UN regulative ECE R10 EMC rev. 5 in accordance with EU regulation
661/2009 for Electronic Sub-Assembly (ESA).
NOTE: Harmonized standards under the directive 2014/30/EU have been
applied.
Statement for ISO 13849-1:
The TU600-x are when installed not a vital part in the machine safety system,
but it can be used as access control/immobilizer if paired with a keypad (e.g.
DualID II) or Ibutton or by Bluetooth LE. This function depends on correct
installation (see installation guide) and requires that the output wire is
connected to a relay to control the starter motor, see installation diagram.
When the emergency stop on the machine is activated, the unit and keypad
functions will be disabled. The internal battery ensures that a GPS position
still can be acquired on an hourly basis.
PRECAUTION: Trackunit recommends only mounting Output1 to starter
motors through a relay and under no circumstances should Output1 be
used to control the engine shutdown during operation or any moving
parts on the machinery.