background image

SP8E Log Splitter

Page 6 

SP8E/0612

Introduction

Before using the Log Splitter please read this manual carefully.  Following all the instructions 
provided will ensure that you get excellent results and the best performance from your Log Splitter.

The CAMON SP8E Log Splitter has been designed and manufactured in compliance with the most 
recent European safety regulations with particular reference to the EN 609-1 and CEI EN 60204-1 
standards.

The two-hands control systems have been designed and engineered so that the operator is forced 
to work in the safety area, employing both hands, without any possibility of inserting hands or arms 
into dangerous areas.

7KLV /RJ 6SOLWWHU LV SURGXFHG LQ FRQIRUPLW\ ZLWK WKH VSHFL¿FDWLRQV FRQWDLQHG LQ WKH

RoHs directive 2002/95/CE.

Before transporting, installing or operating the machine, read all parts of this manual, 

SD\LQJSDUWLFXODUDWWHQWLRQWRWKHVSHFL¿FVDIHW\UHJXODWLRQV

Operators who are unable to understand the language in which this manual is written are responsible 
for asking the retailer to provide a manual in their own language. 

The operator must also train any other person authorised to use the machine. 

Failure to comply in any way with these instructions, improper use of the machine, 
extraordinary maintenance operations not carried out by skilled, authorised personnel, 
removal of data plates or markings of any type, removal or tampering with the guards 
and safety mechanisms of the machine or any other action not expressly authorised 
that may impair the active and passive safety systems of the machine shall relieve the 
manufacturer of all and any liability and may result in serious injury and damage. 

If the machine is tampered with in any way by unauthorised personnel, the guarantee is automatically 
null and void. This manual is an integral part of the machine and must accompany it even in the 
case of transfer of ownership. 

WARNING: The ignition system of your machine produces an 

HOHFWURPDJQHWLF¿HOGRIYHU\ORZLQWHQVLW\7KLV¿HOGFRXOGLQWHUIHUHZLWK

certain pacemakers. To reduce the risk of serious or fatal injury, persons 
with pacemakers should consult their doctor or the manufacturer of the 
pacemaker before using this machine.

!

Summary of Contents for SP8E

Page 1: ...SP8E Log Splitter Operating Instructions Before commissioning the machine read operating instructions and observe warning and safety instructions...

Page 2: ...es 9 11 Safety Page 12 Operating the Machine Page 13 Use Pages 14 15 Routine Maintenance Pages 16 17 Troubleshooting Page 18 Scrapping Disposal of the Machine Pages 19 22 Parts Diagrams Page 23 Part N...

Page 3: ...tric motor The YDULRXV SDUWV RI WKH PDFKLQH DUH VKRZQ LQ J EHORZ 1 ZHB control levers 2 Log pusher 3 Work surface 4 Wedge 5 Fixing pin 6 Carrying handle 7 Foot 8 Electric motor 9 Power supply plug 10...

Page 4: ...SP8E Log Splitter Page 4 SP8E 0612 Illustrations Fig 2 Fig 3 Fig 4 Fig 7 Fig 8 Fig 5 Fig 6 Fig 9 Fig 10a Fig 10b...

Page 5: ...SP8E Log Splitter SP8E 0612 Page 5 Illustrations Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 DO NOT USE THE MACHINE OUTDOORS WHEN IT IS RAINING OR SNOWING...

Page 6: ...n are responsible for asking the retailer to provide a manual in their own language The operator must also train any other person authorised to use the machine Failure to comply in any way with these...

Page 7: ...is forbidden to stand in the range of action of the machine apart from the operator no other person or animal may be present within a radius of 5 metres from the machine Dumping of used oil in the en...

Page 8: ...3OHDVH QRWH WKDW WKH GLDPHWHU RI WKH ORJ LV LQGLFDWLYH D VPDOO ORJ FDQ EH GLI FXOW WR VSOLW LI LW KDV NQRWV RU D SDUWLFXODUO WZLVWHG EUH Recommended oils We recommend use of the following oils for th...

Page 9: ...ge to be ascribed to improper use of the machine 7KH RSHUDWRU PXVW ZRUN LQ WKH SRVLWLRQ VKRZQ LQ J RQ SDJH SRV RQO DQG operate the machine drive control with both hands without using other improvised...

Page 10: ...de the freedom of movement of the operator HHS WKH ORJ VXSSRUW EHQFK IUHH RI ZDVWH PDWHULDOV SDJH J QR DQG HQVXUH WKDW WKH operator s work space is free of obstacles logs chippings sawdust etc KHFN WK...

Page 11: ...with the norms P UDWHG IDXOW FXUUHQW with a ground connection Use cables with a section of 2 5mm2 Avoid use of free and inadequately insulated connections Connections must be made with protected mater...

Page 12: ...OH J SDJH DQG WKH IRRW J SDJH DQG VHFXUH WKHP ZLWK WKH appropriate screws supplied Assemble the control levers and the relative protection Assemble the levers and the relative protection and secure i...

Page 13: ...les on the three phase motor Check that the motor runs in the correct direction as indicated by the arrow Never open the box containing the switch or open the terminal block on the motor If it is nece...

Page 14: ...RE STARTING WORK MAKE SURE THAT THE SPRING IS FIRMLY IN PLACE IN THE PIN Use of the Log Splitter Do not use the machine outdoor when it is raining or snowing Make sure that the switch cut out of the g...

Page 15: ...stop and rotate the log by 90o to see whether it can be split in a different position If you are not able to split the log this means that its hardness exceeds the capacity of the machine and that lo...

Page 16: ...SXVK LW DORQJ RQ LWV ZKHHOV J SDJH VVHPEO DQG XVH RI ZD ZHGJH RSWLRQDO DQG VOLS RQ ZHGJH RSWLRQDO The CAMON SP8E Log Splitter can be equipped with a 4 way wedge to split a trunk into four logs with a...

Page 17: ...o persons or animals or damage How to change the hydraulic oil The spent oil must be replaced with new oil of the type indicated on page 8 recommended oils every 600 hours of operation To change the o...

Page 18: ...USED OIL MUST BE DISPOSED OF ACCORDING TO CURRENT REGULATIONS IN THE COUNTRY WHERE THE MACHINE IS USED Sharpening the wedge After long periods of operation and when required sharpen the wedge of the...

Page 19: ...ry Check that the connections are not restricted or the pipes damaged in the system from the tank to the pump If problem persists contact your dealer Foamy oil comes out from the OOHU FDS Oil leak fro...

Page 20: ...QG HOHFWULF SDUWV FRUUHFWO R QRW GLVSRVH RI WKHVH LQ WKH HQYLURQPHQW as they are hazardous pollutants and treat them in accordance with applicable legislation 0DFKLQHV WWHG ZLWK HOHFWULFDO SDUWV PXVW...

Page 21: ...SP8E Log Splitter SP8E 0612 Page 21 Cylinder...

Page 22: ...SP8E Log Splitter Page 22 SP8E 0612 Parts Diagrams...

Page 23: ...B71150150 77 E26760011 15 B82110010 48 E28560200 78 E26840011 16 D80060170 49 E26035096 79 E28300060 17 E26075105 50 E26830055 80 D02102740 18 E26840016 51 D05170300 81 E55760300 19 E26561344 52 E2664...

Page 24: ...HFL FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU QRWLFH Tracmaster Ltd Sovereign Centre Victoria Road Burgess Hill RH15 9LR T 44 0 1444 247689 F 44 0 1444 871612 W www tracmaster co uk E info tracmaste...

Reviews: