background image

 

 

Page 

8

 of 

14

 

 

 

UNPACK THE CARBON PRE-FILTER 

WARNING:  

Carbon can pulverize and dust during shipment, so please install the 

prefilter pack into the basket in an easily cleanable area and take the appropriate 
actions to avoid dust inhalation.  We recommend masks and gloves for this process. 

Carefully remove the plastic bag from the carbon filter and place in the filter tray.  
Ensure all areas of the tray are covered by this carbon filter, all the way to the edges, so 
no light appears. 

 

REINSTALL THE BACK PANEL 

Reinstall the back-access panel, ensuring to close the emergency shut-off toggle switch 
at the bottom.  Plug in and verify proper fan operation and the UV light indicators on the 
control panel are lit.  

 

VERIFY PROPER OPERATION 

Plug the air cleaner in and verify 
proper operation of unit by turning fan 
control knob clockwise and listen for 
the fan.  Verify the UV lights are 
energized by observing the 2 green 
lights on the front panel are lit. 

 

CHOOSE A SUITABLE LOCATION 

Place your TRACS portable air cleaner in the center of the room, whenever possible.  
Set the fan on highest setting when first introducing air purifier to a new space.  Reduce 
fan setting to low when people are not present and return to highest setting when 
people are present.  Move from room to room as needed.  Consider this air purifier a 
“tool” with HEPA & UVC technology to keep the air around you safe to breathe and give 
you peace of mind. 

 

Summary of Contents for 250-P-UVC

Page 1: ...Page 1 of 14 OWNER S MANUAL TRACS Portable UV C Air Purifier Model TRACS 250 P UVC Made in the USA...

Page 2: ...ow to use 5 WARNINGS UV C light dangers 6 Wear masks gloves 6 Unplug for maintenance 6 Contamination is present 6 SET UP OPERATION Unpacking 7 Remove the back panel 7 Install UV Lamps 7 Remove plastic...

Page 3: ...arbon pre filters 9 HEPA filter 9 UV C lamps 10 Clean inspect 10 TROUBLESHOOTING Will not start 11 Control Panel Lights 11 WARRANTY 30 Day Money Back 12 5 Year Mechanical 12 Life time Frame 13 Made in...

Page 4: ...TRACS changes the way you live and breathe in your home or office In order to ensure optimizing the unit s effectiveness and safe use please read this Owner s Manual in its entirety before installing...

Page 5: ...l cycle all the air in a room up to 1000 square feet every 20 minutes Therefore place the unit in the middle of the room where people are present As people speak their airborne droplets are floating a...

Page 6: ...can view indirect UV light but you should not stare directly into the UV lamps TRACS is fitted with a recessed electrical kill switch that turns the unit off when the back panel is removed to ensure...

Page 7: ...uld never defeat the interlock to energize the system with the cover removed INSTALL THE UV C LAMPS Two reflective UV shields located below the prefilter basket cover the UV lamps in order to increase...

Page 8: ...m Plug in and verify proper fan operation and the UV light indicators on the control panel are lit VERIFY PROPER OPERATION Plug the air cleaner in and verify proper operation of unit by turning fan co...

Page 9: ...ear masks and gloves when replacing used HEPA filters Have a plastic bag ready for immediate disposal TRACS is equipped with a locking system to ensure air will not bypass around the HEPA filter In th...

Page 10: ...ves gently insert the replacement lamps into the lamp holders until they snap into place It may be beneficial to wear protective gloves during this procedure as gloves will ensure oils from your skin...

Page 11: ...u may also try the back panel access door emergency cutoff switch It is located underneath the unit Please do not bypass this switch with the access panel removed If this switch is not activated the u...

Page 12: ...ired to obtain warranty performance however your name and address is recorded by this website with your purchase and we should have a record of the sale This warranty does not cover consequential dama...

Page 13: ...resentation or description with respect to this other than as set forth below The warranty and remedies set forth below are exclusive and in lieu of all others oral or written expressed or implied No...

Page 14: ...ad 5 REINSTALL THE BACK PANEL Reinstall the back access panel 6 VERIFY PROPER OPERATION Plug the TRACS commercial portable air cleaner in and verify proper operation of unit by turning fan control kno...

Reviews: