• Secure with screw (item 1, fig. 20) using
a cross-slot screwdriver.
NOTE
: When securing the winch,
other fastening components can be consi -
dered, for example:
For TS500:
- Tapped holes M12 provided in structure
- Mechanical or chemical dowel ensuring
minimum mechanical strength of 1000 kg
in compliance with manufacturer specifi -
cation
For TS250:
- Tapped holes M10 provided in structure
- Mechanical or chemical dowel ensuring
minimum mechanical strength of 700 kg
in compliance with manufacturer specifi -
cation
6 Rigging the load
The load must be rigged using the hook of
the caRol™ wire rope (item 1, fig. 7), equipped
with its safety latch (item 2, fig. 7).
To rig the load, proceed as follows:
1) Open the hook latch by pressing on the end
(hook nose side) and keep it open in this
position.
2) Run the external rigging component (which
may be a sling, etc.) between the hook
nose and the latch.
3) Release the latch to allow it to close (latch
in contact with hook nose).
The load should be rigged using a sling of
appropriate capacity, dimensions and type
for the object to be handled. It is strictly
prohibited to use the caRol™ wire rope as a
sling by running it around an object with the
hook fastened to the wire rope (fig. 8, correct
slinging, fig. 9, prohibited slinging).
7 Setup with idler pulleys (fig. 16 or fig. 17)
The winch can be used with two idler
pulleys.
NOTE
: The diameter of the groove
bottom of the pulleys used must be at least
16 times the diameter of the caRol™ wire
rope (check applicable regulations as may
be required).
NOTE
: If setting up with only one
idler pulley or with more than two idler pulleys,
contact Tractel
®
.
For the setup, proceed as follows:
- secure the winch (see §5)
- unwind the required length of wire rope
to fasten the load by releasing the drum
(see §8.4).
- run the cable through the idler pulleys
(items 1 and 2, figs.16 or 17).
- fasten the load to the hook (item 3,
figs. 16 or 17) on the caRol™ wire rope
(see §13).
8 Commissioning
8.1 Installing the caRol™ wire rope in the
winch
To install the caRol™ wire rope on the drum,
proceed as follows:
• through the interior of the drum, run the
ground end of the caRol™ wire rope
through the clamp (item 1, fig. 10) and
the hole in the drum (item 2, fig. 10).
• allow the caRol™ wire rope to come out
of the exterior side plate of the drum by
around 5 mm.
• Remove the access cover (item 10, fig.
1)
• Tighten the two nuts on the cable clamp
using a 7 mm tubular socket wrench
(fig. 11).
• Reinstall the access cover (item 10,
fig. 1).
• Wind the caRol™ wire rope around the
drum in the direction indicated by the
arrow (fig. 10) so that the wire rope winds
regularly on the drum, layer by layer.
11
GB
All manuals and user guides at all-guides.com