Page 16 sur 37
- When the evacuation is complete, wind the wire rope back into the unit (turning the
handle clockwise). (figure B).
ATTENTION
CAUTION
Never unlock the system if the wire rope is not completely wound in the unit as it
will rewind at high speed.
- To disengage the hoist mechanism, press the red button and the hinge pin of the
operating handle simultaneously. The operating handle must be in the vertical position,
with the knob at the top, in order to carry out this operation.
- Folding operating handle (3) and (4).
3.3 Lifting operation with Blocfor
™ R
All lifting operation with Blocfor™ R is forbidden
The winch is made for rescue operation
For this type of operation we preconized to use a confortable harness EN 361 & EN 813
(type Promast™, Transport , Secours)
3.4 Lifting operation with Carol
™ TS hoist
Rope acces legislation autorise to use the Carol
™ for lift a worker. In this case worker
must connected the harness with a fall arrest system
The worker must connected the lanyard of Carol
™ Winch TS on the ombilical
anchorage EN 813 of harness.
The
Blocfor™ R must be connected to achorage EN
795 or with a resistance of 10 KN. The extremity of wire rope must be connected to fall
arrest anchorage of harness printing with A