7
GB
3.3. Marking
See figure 1.
1
Adjustment screw and locknut for threshold 1
2
Adjustment screw and locknut for threshold 2
3
Option: factory setting parameters for threshold 1
4
Option: factory setting parameters for threshold 2
5
Protection index
6
Microswitch interrupting capacity and voltage
7
Device serial number
8
Identification
9
Symbol indicating «You must read the user manual»
10
QR Code leading to tracinfo, that contains CE certificate, present manual
11
Compatible wire rope diameters
12
Capacity on strand (working load limit)
All indications and labels affixed on the product by the manufacturer must be kept fully legible. If any
indications and labels are removed or damaged, they must be replaced before continuing to use the product.
Tractel
®
can supply new marking materials on request.
3.4.
Technical specifications
Installation
Directly on idle strand
Repeatability
1% FS
Measurement sensor
2 integrated micro switches
Contact 1 : 1 NO, 1 NC
Contact 2 : 1 NO, 1 NC
Category
1 (as EN ISO 13849-1)
Cut-out voltage
250 VAC
Cut-out intensity
2A max/inductive load
4A max/resistive load
Connection
Electrical cable, 7 conductors
Electrical output
Cable gland
Lenght of cord
2 meters
Calibration system
By screws
Hysteresis
Between 50 and 200 kg depending on the effort
Operating temperature
-30° to +80°C
Protection degree
IP67
Material
Aerospace quality aluminium
Surface treatment
Anodizing Body
Maintenance
None
Technical Data of the Micro switches:
•
Type: V4NST7-UL
•
According: UL, CSA, ENEC
•
Mechanical life: 5 x 10
6
cycles minimum (impact free actuation)
Maximum electrical ratings:
Recommended Maximum Electrical Ratings