Installation and operating manual
EN-24
G961.1 - 03/2012
The maximum overload must be lifted in order to set the load
limiting device.
Overload = maximum working load + 25 %
Adjusting the mechanical load limiting device
See Fig. 30.
–
Load the load lifting equipment with the calculated overload.
–
Raise the load.
The load limiting device must react and stop the UP travel of
the hoist within the first 10 cm.
If the load limiting device does not react:
–
Remove the blanking plug (1).
–
Loosen the brass screw (2).
–
Insert an 8 mm, 150 mm-long Allen key into the setting
screw (3).
–
Loosen the setting screw (3) until the load limiting device
reacts.
–
Lower the overload to the ground.
–
Raise the overload again.
The load limiting device must react. Otherwise repeat the
procedure.
The load limiting device must not react when the hoist is loaded
to the maximum working load.
–
Load the load lifting equipment with the maximum working
load.
–
Raise until the load lifting equipment hangs freely.
The load limiting device must not react when lifting the load.
If the load limiting device reacts:
–
Lower the load to the ground.
–
Insert an 8 mm, 150 mm-long Allen key into the setting
screw (3).
–
Tighten the setting screw (3) one half turn.
–
Raise the load again.
The load limiting device must not react when lifting the load.
If setting screw (3) was adjusted, repeat the test with the maxi-
mum overload.
–
Load the load lifting equipment with the calculated overload.
–
Raise the load.
The load limiting device must react and stop the UP travel of
the hoist within the first 10 cm.
–
Tighten the brass screw (2).
–
Replace the blanking plugs (1) and secure with red sealing
wax.
Adjusting the electronic load limiting device (optional)
DANGER!
Danger of death due to electric shock!
–
Disconnect the power supply to the hoist by disconnect-
ing the connector before opening the terminal box.
–
Do not touch any conducting parts when performing the
adjustment.
–
Cover conducting parts if necessary.
Risk of being injured by falling objects!
Might result in severe injuries or even death!
–
The load limiting device may only be implemented by
personnel authorized by the system manufacturer or
TRACTEL Greifzug GmbH.
–
Observe the details in this instruction manual.
The electronic load limiting device reacts to the power consump-
tion of the motor. Hoists with two speeds are equipped with two
electric load limiting devices. The adjustment must be made for
both load limiting devices and speeds. The overload is recog-
nized when lifting.
A lower limiting value, e. g. due to a lower load bearing capacity
of the anchoring points, must only be set by authorized mainte-
nance personnel.
Default setting
See Fig. 28.
–
Remove the sealing wax on the controllers (1) and (2).
–
Turn the upper controller (1) for the rated power to the right
to the limit.
–
Turn the lower controller (2) for the start monitoring to the
right to the limit.
Adjusting the overload
–
Load the load lifting equipment with the calculated overload.
–
While lifting the excessive load turn the upper controller (1)
to the left until the hoist stops.
–
Lower the excessive load until the rope is unloaded.
–
Raise the excessive load again:
The hoist must stop as soon as it comes under load.
Adjusting the start override
–
Load the load lifting equipment with the maximum working
load.
–
Raise the nominal load from the ground.
–
Turn the lower controller (2) to the left to the limit.
–
Press the UP button.
The hoist must stop immediately.
Note:
Briefly press the DOWN button every time after stopping the
hoist during this setting procedure in order to re-enable the rais-
ing movement.
Summary of Contents for Tirak MWX 1020
Page 5: ...MWX 500 1537 G961 1 03 2012 EN DE FR NL V Fig Abb Fig Afb 1 ...
Page 12: ...MWX 500 1537 EN DE FR NL XII G961 1 03 2012 ...
Page 42: ...Installation and operating manual EN 30 G961 1 03 2012 ...
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ...G961 1 03 2012 105110 EN DE FR NL TRACTEL Greifzug GmbH ...