background image

5347-MAN-038-EN1-01 230VAC 

4.5.

 

An extension cord should not be used unless 

absolutely necessary. Use of an improper 

extension cord could result in a risk of fire and 

electric shock. If an extension cord must be 

used, make sure: 

 

a) That the pins on plugs of the extension cord 

are the same number, size, and shape as those 

of the plug on the charger; 

 

b) That the extension cord is properly wired and 

in good electrical condition;  

 

c) That the wire size is large enough for the AC 

ampere rating of charger as specified in the 

following table 

 

Recommended minimum AWG size for extension cords for battery support units 

AC input rating Amperes 

AWG size of cord 

Length of cord, M 

 

7.5 

15 

30 

45 

8-10 

18 

14 

12 

10-12 

16 

14 

10 

12-14 

16 

12 

10 

14-16 

16 

12 

10 

16-18 

14 

12 

10 

 

5.

 

Connecting to a vehicle 

 

Please follow dealer standards guidelines for 

connection methods.  

 

Traction units are supplied with vehicle specific 

adapters that should be used at all times. 

Failure to use the adapters in the positions 

prescribed could result in excessive heat being 

generated in the lead set leading to premature 

failure of leads and low voltage output. 

 

Output leads are connected using the polarised 

connectors on the unit and lead set. 

 

The primary method for powering the support 

unit is via the AC power cord. 

 

6.

 

Warranty and Service. 

For technical support call 866-628-5508 or email 

oetech@service-solutions.com

For repair service, go to  

repairtrack.bosch-automotive.com 

or call 800-344-4013 

7.

 

Manufacturer Information 

Traction products are manufactured by: 

Traction Chargers 

Roundway Hill Business Centre 

Devizes 

Wiltshire 

SN10 2LT UK 

 

+44(0)330 022 7822 

admin@tractioncharger.com

 

 

This symbol is used on products that contain a hazardous element and therefore 

cannot be thrown away in the normal way. it appears on Electrical and Electronic 

Equipment (EEE) as part of the WEEE (Waste EEE) directive – separate collection 

facilities will be set up to divert WEEE away from landfill; funded by producers and 

retailers of EEE

 

 

 

 

Summary of Contents for MPL50

Page 1: ...5347 MAN 038 EN1 01 230VAC MPL50 Operating Instructions MPL12 50A INSTRUCTION MANUAL ...

Page 2: ...educe the risk of injury only charge rechargeable flooded type batteries including maintenance free low maintenance or deep cycle batteries WARNING Risk of explosive gases Batteries generate explosive gases during normal operation and when discharged or charged 1 4 Never charge a frozen battery 1 5 To reduce the risk of damage to the electric plug and cord pull by the plug rather than by the cord ...

Page 3: ... battery is well ventilated while the battery is being charged Gas can be forcefully blown away by using a piece of cardboard or other non metallic material as a fan 3 2 If it is necessary to remove the battery from vehicle to charge it always remove the grounded terminal from the battery first Make sure all accessories in the vehicle are off so as not to cause an arc 3 3 Study all battery manufac...

Page 4: ...e specific adapters that should be used at all times Failure to use the adapters in the positions prescribed could result in excessive heat being generated in the lead set leading to premature failure of leads and low voltage output Output leads are connected using the polarised connectors on the unit and lead set The primary method for powering the support unit is via the AC power cord 6 Warranty...

Page 5: ...maintenance free battery A Amps 9 Technical Specification Environmental Information Working Temp C Working Humidity Storage Temp C Storage Humidity Input Voltage Range Input Current Typ O P Rated Current O P Rated Power Dimensions WxHxD O P Fuse Type 0 to 40 20 90 non condensing 40 85 10 95 RH 230 240VAC 6 5A 240VAC 50A 750W 280 x 230 5 x 260mm F2 63A BS88 240Vac 50kA Min ...

Page 6: ... CHARGER D IF REQUIRED SWITCH ON THE ELECTRICAL SUPPLY FOLLOWED BY THE CHARGER ON SWITCH IF FITTED E MAKE SURE THAT THE MAINS POWER RED LED IS ILLUMINATED F ALL THE RED LED S WILL FLASH CONSECUTIVELY G THE CHARGING AMBER LED WILL ILLUMINATE FOLLOWED BY THE FIVE RED LED S SHOWING PERCENTAGE OF CHARGE H WHEN THE CHARGE IS COMPLETE THE GREEN LED WILL ILLUMINATE THE BATTERY CHARGER CAN BE LEFT CONNECT...

Page 7: ... RED 60 3 LAMPS RED 80 4 LAMPS YES BATTERY FLAT BULK CHARGE AMBER LIGHT FLASHING PARTLY CHARGED BATTERY TIMER RUNNING DEEPLY DISCHARGED DE SULPHATION PROGRAM IN OPERATION HIGH IMPEDENCE YES GREEN LAMP CHARGE COMPLETE LEAVE ON UNTIL REQUIRED CYCLE COMPLETE BATTERY DID NOT REACH FULL CHARGE TEST BATTERY ON OFF FLASHING NO DEEPLY DISCHARGED DE SULPHATION PROGRAM IN OPERATION LOW IMPEDENCE RED 100 ALL...