background image

GS503-V1

Overall Size: 3070 x  1000 x 1920mm

Shed Size: 3070 x  790 x 1900mm

Door Size: 1480 x 1750mm

Floor Size: 3030 x 750mm

GARDEN SHED OWNER’S MANUAL

AND ASSEMBLY INSTRUCTIONS

AND ASSEMBLY INSTRUCTIONS

GARDEN SHED OWNER’S MANUAL

3070

790

1920

1800

1000

1480

Summary of Contents for GS503-V1

Page 1: ...x1000 x 1920mm Shed Size 3070 x 790 x 1900mm Door Size 1480 x 1750mm Floor Size 3030 x 750mm GARDEN SHED OWNER S MANUAL AND ASSEMBLY INSTRUCTIONS AND ASSEMBLY INSTRUCTIONS GARDEN SHED OWNER S MANUAL 3...

Page 2: ...into position Remember to leave plenty of room for the door to fully open An electric drill driver A Phillips screwdriver Gardening or work gloves Sealant or caulking gum optional Step ladder Tape mea...

Page 3: ...loor kits designed to match your shed Alternatively you can build your own using H4 treated bearers and timber floorboards Build on a compacted and levelled base layer Plastic sheeting placed under th...

Page 4: ...underneath the corrugation as you drill providing support for the panel until the screw is all the way in Make sure the block is not directly underneath the screw How to remove rivets if needed Don t...

Page 5: ...ASSEMBLY INSTRUCTIONS...

Page 6: ...0 4 2 Drill Bit 1 Screw Head Sheath 30 Phillips Head Screws 20 14 15 16 18 19 20 Z111 21 22 E175 x 410 E175 x 350 U074 U175 D173 H074 DOOR PART QTY PART 23 24 25 26 2 2 4 4 2 2 4 SIZE mm 410 x 1750 35...

Page 7: ...Part W190 x8 i U155 U155 U155 U155 All panels shouldoverlap by one corrugation U155 x4 b Lay the wall panels out with the large rib overlapping the small Large Rib Small Rib Joint outside Joint inside...

Page 8: ...t each end of the panel These need to be left undone Assemble the side wall panels Tek Screw Screw from the outside in as per the pre drilled holes in the frame L190185x1 R180185x1 R185190x1 L185180 R...

Page 9: ...panel All pre drilled holes should line up with the peaks of the steel sheet If this varies squeeze together or stretch out the panels to make sure they line up Do not add screws to the top and botto...

Page 10: ...ndone Leave the left and right door frames MR180 ML180 un fastened at this stage This will help with any adjustments needed later on Once the door positioning is finalised add the necessary screws Tek...

Page 11: ...st however when the roof is secured in place it is completely rigid Assemble the roof panels P100x8 U155x4 b c All panels should overlap by one corrugation 6 STEP 5 a i Tek Screw U155 U155 U155 U155 U...

Page 12: ...x2 U175 x 4 U074x4 Rivet D173x2 Square tube Out side of door E175 x 350 E175 x 410 D173 Square tube insert D173 square tube into U195 frame screw rivets E175 x 350 x1 E175 x 410 x1 In side of door Ou...

Page 13: ...move the hinge down until it is level with mark drill holes for your rivets and attach Use the drill bit to drill pilot holes through the door bracing into the door sheeting Flip the door back over to...

Page 14: ...9 rivets with washer galvanized handle door center strip door top strip door bottom strip door bar door inside door outside handle hasp hinges inside bolt for double door double door hasp on door...

Page 15: ...weather Afterwards tack the sheets together down the length of each corner Corner Anchor x8 STEP 7 i To form a flush corner connection make sure the end corrugations overlap as shown above When addin...

Page 16: ...mend you drill the roof screws though the sheet at the base of the corrugation Once you have your roof in position go inside and drill up through the corner anchors of the shed This will ensure you wi...

Page 17: ...m First drill a hole from inside of wall panel then fixed by revits from outside please make 2 holes in middle of connection point and other equidistant holes for the rest of brace Take care to ensure...

Page 18: ...the position later if required to get a good fit The screws can be changed for rivets when the door position is finalised 13 Rivet Drill pilot holes to accommodate the pad bolt keeper and then fix wi...

Page 19: ...perly aligned when closed then if needed adjust door frame jamb hinges accordingly To create or reduce space adjust the door frames which have been left unfastened as per Step 3 C by sliding them back...

Page 20: ...oof can damage the structure making it unsafe to enter DOORS Keep doors closed and locked to prevent wind damage FASTENERS Use all washers supplied to protect the shed panels against weather Regularly...

Page 21: ...Still having trouble Just give us a call or send us an email Head over to tradetested co nz or tradetested com au for all of our contact details and opening hours We will be able to help...

Reviews: