User Manual
THIS DOCUMENT IS UNCONTROLLED WHEN PRINTED
Page
32
of
34
10.
Trouble shooting
Product / arm not operating:
Possible issue
Guidelines
ON/OFF switch
•
When ON a green light is illuminated on the front of the control panel.
•
If not illuminated Open Control Panel and check that all switch wiring is securely fastened
to the PCB
•
If the switch is considered faulty or damaged contact your distributor for a replacement
switch
Main control board fuse is blown
•
The fuse is located at the back of the main PCB
–
If blown contact distributor for a
replacement fuse.
Inline fuse is blown
•
The inline fuse is located at the bottom of the unit near the battery encased in black
plastic
–
If blown contact distributor for a replacement fuse.
Battery charge
•
Check low battery indicators on the control panel
–
If flashing red charge battery by
connecting a charging lead to the 240V outlet (located bottom left of unit) to a 240V
power point
–
When battery starts to charge the red advisory light will go out.
Boom arm low or high:
Possible issue
Guidelines
Inclinometer calibration
•
Check inclinometer PCB positioning on mechanics located on Arm near motor
–
Ensure
bracket and PCB is securely fastened to mechanics with the use of hex screws.
•
Check inclinometer PCB wiring to main PCB is securely fastened
–
Main PCB located
behind the Control Panel.
•
Re-calibrate Arm to required level following instructions provided.
Stability legs wont slide:
Possible issue
Guidelines
Wing nut
•
Ensure wing nut is wound back to nut
–
The wing nut is located to the top of the stability
leg
Adviso
ry LED’s
unresponsive:
Possible issue
Guidelines
LED/s not working
•
Check wiring connection to terminal block on PCB located at the back of the Control Panel.
•
Replace LED/s
–
refer distributor for assistance.
Manual push button unresponsive:
Possible issue
Guidelines
Push button unresponsive
•
Open Control panel and check that the wiring is securely fastened to the PCB.