83
TRAK Machine Tools
Southwestern Industries, Inc.
32240 - Printer and MMS - Installation & Printing Guide
9.
Use the Dial Indicator to ensure the nozzle
height is within tolerance.
10.
Once it is within tolerance, tighten the
screw for that nozzle, and then tighten the
Tube Adapter to lock it into place.
11.
Place the Adapter Bracket back on, and
tighten the screws.
12.
Connect the Bowden Tubes back onto the
Tube Adapter.
13.
Reconnect the Pin Head Connector.
14.
Replace the top cover, and secure it into
place using the screws.
Feel free to run the
Z_Comparison.gcode
file
again, if you would like to ensure the heights are
within tolerance.
15.
Remove the Dial Indicator.