Page 5
TEF 4600 CONTROL SYSTEM -
INSTALLATION AND USER MANUAL
10 OPERATION
10.1 Control Screen
The Control Screen contains control and monitoring of
Helideck lights. Each button controls one light circuit.
The circuits are toggled on and off by pressing and hold-
ing the button for 1 second.
From the Setup page, the circuits that are in use should
be selected. Only the selected circuits will show in the
Control screen.
Each button has four modes to represent circuit status:
Green: Circuit is on.
Grey: Circuit is off.
Red: Circuit is on with error.
Yellow: Circuit is off with error.
The available lights to control are:
Helideck lights: Turn on/off all Helideck lights.
(Flood-
lights Dim and Circle & H and Status lights not included.)
Floodlight 1:
Turn on/off Flood light circuit 1.
Floodlight 2
Turn on/off Flood light circuit 2.
Floodlight Dim:
Activate standard/dim
brightness of Floodlight circuits.
Perimeter light 1:
Turn on/off Perimeter light
circuit
1.
Perimeter light 2:
Turn on/off Perimeter light
circuit
2.
Circle & H:
Turn on/off Circle & H circuit.
Circle & H Bright:
Activate standard/bright
brightness of Circle & H circuits.
Windsock:
Turn on/off Windsock
circuit.
Obstruction light:
Turn on/off Obstruction light
circuit.
Auxiliary light 1:
Turn on/off Auxiliary light 1
circuit.
Auxiliary light 2:
Turn on/off Auxiliary light 2
circuit.