background image

TEF 9964

  

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

INTRODUCTION

Thank you for purchasing this product!
For installation, maintenance and assurance of a long life 
of this product, please follow this manual.

CONTENT IN BOX

The product is fully assembled, and ready for installation.

SAFETY PRECAUTIONS

Note that changes made to the product and/or installation 
of components which do not conform to the approval, 
may be a safety violation. The  manufacturer will in no 
circumstance be held responsible for such activity.
For your health and safety, always use safety gear suited 
for the task. Be certain to follow codes, regulations and/or 
specifi c procedures that are related to the installation.

TOOLS REQUIRED

Regular tools required for installation:

• 

17 mm wrench –for assembling the fl oodlight.

• 

13 mm wrench –for adjusting the angle of the light.

• 

8 mm fl at screwdriver –for open/closing the cover of the 

junction box.

• 

3 mm fl at screwdriver –for installing the cable in the 

terminal block.

• 

5,5 mm fl at screwdriver –for removing the lamp insert.

• 

32 mm wrench -to assembly the cable gland

• 

30 mm wrench -to tighten the lock nut and the pressure 

nut

MAINTENANCE INSTRUCTIONS

The luminaire should be inspected according to Company 
routines. The manufacturer suggests regular check for 
water intrusion/condensation which should be removed 
immediately. Check the drain plug / drain hole function. 
When  cleaning,  use  only  mild detergents. Alcohol or 
petroleum based products may damage lens, paint or 
plastic components.

RUBBER SEAL

Cable diameter

Size

Part No.

8,5 - 13,5mm

Ø23/13x8mm

5002 0124

13 - 17mm

Ø23/16x8mm

5002 0125

Be sure to install the cable in a way wich prevents water to penetrate into the enclosure through the cable gland, 
also make sure to use the correct rubber seal when you install the luminaire

APPLICATIONS

• 

Floodlighting of helicopter landing areas

• 

For use safe area

• 

Floodlighting

APPROVALS

CSA 
International,            216432
Canada
Complies with:  CSA Standard C22.2 No 0-M91
 

 

CSA Standard C22.2 No 0.4-M1992

 

 

CSA Standard C22.2 No 43-M1984

 

 

CSA Standard C22.2 No 250.0-00

 

 

UL 1598-2000, First edition

 

 

UL 542-1999, Eight edition

 

 

UL 935-2001, Tenth edition

Summary of Contents for TEF 9964

Page 1: ...om www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV E 06 02 14 ...

Page 2: ...rminal block 5 5 mm flat screwdriver for removing the lamp insert 32 mm wrench to assembly the cable gland 30 mm wrench to tighten the lock nut and the pressure nut MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular check for water intrusion condensation which should be removed immediately Check the drain plug drain hole functi...

Page 3: ...deck unless stated otherwise 2 Secure the floodlight to the helideck by means of four M10 bolts 3 Open the enclosure cover on rear Replace cable gland gaskets as required to match the cable diameter Unused cable glands should always be replaced with a blind plug 4 Connect cables and replace the enclosure cover DIMENSIONS 5 Luminaire housing shall be connected to earth potential by groundwire of min...

Page 4: ...nt ring Warning High voltage components inside lamp Make sure to disconnect power before opening Distance bracket Distance bracket Holding clip Old version 2 REMOVE HOLDING CLIP AND OR DISTANCE BRACKET 1 REMOVE FRONT RING 3 SLIDE OUT LAMP INSERT New version ...

Page 5: ...eflector unit 3 x M4 screws Disconnect the hight voltage plug 4b 2 Position lamp removal tool over locking ring as shown below Twist approx 30 degrees anti clockwise 4b 3 Remove xenon lamp Locking ring Xenon lamp 4A REMOVE LIGHT BULB NEW VERSION 4B REMOVE LIGHT BULB OLD VERSION Note make sure the new xenon bulb is clean Do not touch the glass part of the bulb Mount lamp back together in reversed or...

Page 6: ...ing to EN 60529 IP rating with drain plug IP 66 Cable glands 2 X M25 cable diam 8 5 13 5mm 13 0 17 0mm Area of use Safe area Weight 10 kg SPARE PARTS Part No Xenon Lamp D2S 35W For TEF 9964 9400074 Front Glass 3141 High Voltage Igniter Unit Xenon 9400103 Locknut for Xenon D2S 9400108 Transformer W Mounting Bracket for 9964 230 254 VAC 4386 Transformer W Mounting Bracket for 9964 110 VAC 4387 Recti...

Page 7: ...4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com ...