background image

4a-1:

Disconnect the high voltage plug from the light bulb. 
Position lamp removal tool over locking ring as shown 
below. twist approx. 30 degrees anti-clockwise.

4a-2:

Remove xenon lamp

Xenon lamp

Locking ring

4b-1:

Disassemble the refl ector unit. 3 x M4 screws
Disconnect the hight voltage plug.

4b-2:

Position lamp removal tool over locking ring as shown 
below. Twist approx. 30 degrees anti-clockwise.

4b-3:

Remove xenon lamp

Locking ring

Xenon lamp

4A.  REMOVE LIGHT BULB, NEW VERSION

4B.  REMOVE LIGHT BULB, OLD VERSION

Note: make sure the new xenon bulb is clean. Do not touch the glass part of the bulb.

 

Mount lamp back together in reversed order.

 

5.  INSERT NEW XENON BULB

Summary of Contents for TEF 9964

Page 1: ...om www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV E 06 02 14 ...

Page 2: ...rminal block 5 5 mm flat screwdriver for removing the lamp insert 32 mm wrench to assembly the cable gland 30 mm wrench to tighten the lock nut and the pressure nut MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular check for water intrusion condensation which should be removed immediately Check the drain plug drain hole functi...

Page 3: ...deck unless stated otherwise 2 Secure the floodlight to the helideck by means of four M10 bolts 3 Open the enclosure cover on rear Replace cable gland gaskets as required to match the cable diameter Unused cable glands should always be replaced with a blind plug 4 Connect cables and replace the enclosure cover DIMENSIONS 5 Luminaire housing shall be connected to earth potential by groundwire of min...

Page 4: ...nt ring Warning High voltage components inside lamp Make sure to disconnect power before opening Distance bracket Distance bracket Holding clip Old version 2 REMOVE HOLDING CLIP AND OR DISTANCE BRACKET 1 REMOVE FRONT RING 3 SLIDE OUT LAMP INSERT New version ...

Page 5: ...eflector unit 3 x M4 screws Disconnect the hight voltage plug 4b 2 Position lamp removal tool over locking ring as shown below Twist approx 30 degrees anti clockwise 4b 3 Remove xenon lamp Locking ring Xenon lamp 4A REMOVE LIGHT BULB NEW VERSION 4B REMOVE LIGHT BULB OLD VERSION Note make sure the new xenon bulb is clean Do not touch the glass part of the bulb Mount lamp back together in reversed or...

Page 6: ...ing to EN 60529 IP rating with drain plug IP 66 Cable glands 2 X M25 cable diam 8 5 13 5mm 13 0 17 0mm Area of use Safe area Weight 10 kg SPARE PARTS Part No Xenon Lamp D2S 35W For TEF 9964 9400074 Front Glass 3141 High Voltage Igniter Unit Xenon 9400103 Locknut for Xenon D2S 9400108 Transformer W Mounting Bracket for 9964 230 254 VAC 4386 Transformer W Mounting Bracket for 9964 110 VAC 4387 Recti...

Page 7: ...4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com ...

Reviews: