Electrical — Low Voltage
TAMX can be used in either Link Communicating mode
or 24 volt mode. In Link Communicating mode, all
configurations are made by using the configuration
menu in the User Interface (UX360) or from the
Diagnostic Mobile App. In 24 volt mode, basic
operation is configured from the factory with no
defaults for accessories. All configurations for blower
delays, accessories etc., need accomplished using the
Diagnostic Mobile App.
Table 14.
Low Voltage Hook-up Instructions
Note:
Strain relief must be provided on the inside of the air handler
cabinet for the low voltage wiring. Field supplied thermostat
wired may be wire tied as a bundle to the existing strain
relieved low voltage pigtail leads in the air handler unit.
1.
Route control wiring to unit. Remove the external sheathing of
the wiring approximately 5”.
Note:
Optional Low Voltage Conduit Entry Kit number BAYLVKIT100A
is available.
5”
2.
Remove Coil panel by turning the Phillips head door fasteners,
rotating the door away from the cabinet.