background image

Gas Furnaces — Non-Condensing
Fan Assisted Combustion System
Upfl ow / Horizontal  and  Downfl ow / Horizontal

User’s Information Guide

Contents

Dangers, Warnings & Cautions 

1

General Information 

1

To Start the Furnace 

2

Proper Maintenance 

4

The Problem Solver 

6

Regular Dealer Maintenance 

7

Warranty 9

GENERAL INFORMATION

Understand the signal words 

WARNING

 and 

CAUTION

These words are safety alert words. 

WARNING 

indicates 

hazards which 

could

 result in personal injury or death. 

CAUTION 

is used to indicate unsafe practices which could 

result in minor injury or property damage.

IMPORTANT FACTS

The fl ow of combustion and ventilating air must not be ob-
structed from reaching the furnace. Air openings provided 
in the casing of the furnace must be kept free of obstruc-
tions which would restrict airfl ow, thereby affecting effi -
ciency and safe operation of your furnace.

Also, air openings provided to the area in which the furnace 
is installed and the space around the furnace shall not be 
blocked or obstructed. Keep this in mind should you choose 
to remodel the area which contains your furnace. If addi-
tional insulation is added after the furnace is installed, the 
area around the furnace must be inspected to ensure it is 
free and clear of insulation. If this furnace is installed in an 
attic or other insulated space it must be kept free and clear 
of all insulating materials as some insulating materials are 
combustible.

Furnaces must have air for proper performance. There 
must be a free fl ow of fresh air suffi cient for effi cient com-
bustion and safe ventilation of your furnace.  

The combustion air for your furnace must be fresh uncon-
taminated air.  Paints, varnishes, laundry bleaches, de-
tergents, many household cleaners, water softening salts, 
adhesives, and all such products release fumes containing 
compounds which could lead to early heat exchanger and 
vent system deterioration.  Do not store these types of prod-
ucts near your furnace.

WARNING

!

SAFETY HAZARD

DO NOT USE THIS UNIT IF ANY PART HAS BEEN UNDER 
WATER. IMMEDIATELY CALL A QUALIFIED SERVICE 
TECHNICIAN TO INSPECT THE FURNACE AND TO RE-
PLACE ANY PART OF THE CONTROL SYSTEM AND ANY 
GAS CONTROL WHICH HAS BEEN UNDER WATER.

FAILURE TO FOLLOW THIS WARNING MAY RESULT IN 
PERSONAL INJURY, PROPERTY DAMAGE, OR DEATH.

WARNING

!

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property 
damage, personal injury or loss of life.

— Do not store or use gasoline or other flammable 

vapors or liquids in the vicinity of this or any  
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch;  

do not use any phone in your building.

• Immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 
instructions.

• If you cannot reach your gas supplier,  

call the fire department. 

— DO NOT RELY ON SMELL ALONE TO DETECT 

LEAKS. DUE TO VARIOUS FACTORS, YOU MAY 
NOT BE ABLE TO SMELL FUEL GASES. 

• U.L. recognized fuel gas and CO detectors are 

recommended in all applications, and their 
installation should be in accordance with the 
manufacturer's recommendations and/or local 
laws, rules, regulations, or customs.

— Installation and service must be performed by a 

qualified installer, service agency or the gas 
supplier.

Available in French Canadian (FC)

32- 5027- 13

Summary of Contents for 32- 5027- 13

Page 1: ...ventilation of your furnace The combustion air for your furnace must be fresh uncon taminated air Paints varnishes laundry bleaches de tergents many household cleaners water softening salts adhesives...

Page 2: ...LOW THIS WARNING MAY RESULT IN PERSONAL INJURY PROPERTY DAMAGE OR DEATH Lighting instructions Your furnace does not use a continuously burning pilot flame Therefore manually lighting your furnace is n...

Page 3: ...r or gas supplier For complete shutdown Turn gas cock knob on main gas valve to OFF position Disconnect electrical supply to unit CAUTION If this is done during the cold weather months provisions must...

Page 4: ...pe which are the same size as originally supplied How to remove your filter WARNING SAFETY HAZARD DISCONNECT POWER TO UNIT BEFORE MOVING THE BLOWER DOOR FAILURE TO FOLLOW THIS WARNING MAY RESULT IN PE...

Page 5: ...with your dealer for the exact location of your filter and the method of changing the filters UPFLOW FILTER TABLES REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 14 1 2 1 14 X 25 X 1 17 1...

Page 6: ...make any adjustments to your furnace Your dealer will be able to take care of any questions or problems you may have A periodic inspection of your furnace should be made by a qualified service agency...

Page 7: ...FE OPERATION OF THE FURNACE FAILURE TO FOLLOW THIS WARNING MAY RESULT IN PERSONAL INJURY PROPERTY DAM AGE CARBON MONOXIDE POISONING OR DEATH 3 IGNITER This unit has a special hot surface direct igniti...

Page 8: ...onstantly filtered air and aid in maintaining more even tempera tures by avoiding temperature stratification through out the conditioned area To accomplish constant air circulation set your thermostat...