background image

 

 18-AD41D1-1B-EN

Installer’s Guide

CAUTION

!

Caution: This coil is pressurized with 8-12 psig of dry 

air. Do not stand directly in front of the coil connections 

when removing sealing plugs. If no pressure is released, 

check for leaks.  

C.  RECOMMENDATION

If a coil is part of the total system installation, use the Installer’s 
Guide packaged with the furnaces, outdoor sections, and ther-
mostat for physically installing those components.

UPFLO

W

FURNA

CE

CASED

COIL

SCREWS

(BOTH SIDES)

SELF TAPPING SCREWS (4)
1-1/2” MAXIMUM
FIELD SUPPLIED

FOR UPFLOW / 

HORIZONTAL LEFT 

INSTALLATIONS

E.  FURNACE IN DOWNFLOW POSITION

1.  UPFLOW COIL CONVERSION (Models: 

4PXCBU36BS3HAB, 4PXCCU36BS3HAB,  

4PXCBU42BS3HAB, 4PXCCU42BS3HAB,  

4PXCBU48BS3HAB, 4PXCCU48BS3HAB,  

4PXCDU48BS3HAB, 4PXCCU60BS3HAB, 

4PXCDU60BS3HAB only)
a. For maximum efficiency, remove the factory installed 

two-piece baffle assembly from the apex of the coil by 

removing the 5/16” hex head screws. See Figure 2.

b. Replace only the top baffle using the same screws 

previously removed.

1.  DOWNFLOW GAS FURNACE  

When a coil is used with a downflow furnace, a subbase 

is not required between the coil case and combustible 

flooring.  
a. Place the coil case on the furnace supply air plenum.
b. Secure the coil case to the plenum. 
c. Set the furnace on top of the coil case, making sure 

that the back side of the discharge opening is snug up 

against the duct flange at the top rear of the coil case.

d.  Secure  the  coil  case  to  the  furnace  and  seal  for  air                                                                                                                                              

leaks as required.

CAUTION

!

Caution: This coil is pressurized with 8-12 psig of dry 

air. Do not stand directly in front of the coil connections 

when removing sealing plugs. If no pressure is released, 

check for leaks.  

D.  FURNACE IN UPFLOW POSITION  

     APPLICATION USES UPFLOW COIL MODELS ONLY

IMPORTANT:  

If installing the coil in the horizontal position, you MUST

 

use the horizontal kit listed below for this coil model num

-

ber and follow the instructions in the installation guide 

provided with the conversion kit.

Model Number

Horizontal Kit No.

4PXCAU24BS3HAB
4PXCAU32BS3HAB 
4PXCBU24BS3HAB 
4PXCBU30BS3HAB 

4PXCCU30BS3HAB
4PXCBD30BS3HDB

BAYCONV18B

4PXCBU36BS3HAB

4PXCCU36BS3HAB
4PXCBD36BS3HDB
4PXCCD36BS3HDB

BAYCONV23B

4PXCBU42BS3HAB

4PXCCU42BS3HAB

4PXCBU48BS3HAB

4PXCCU48BS3HAB
4PXCDU48BS3HAB
4PXCBD42BS3HDB
4PXCCD42BS3HDB

BAYCONV27B

4PXCCU60BS3HAB
4PXCDU60BS3HAB
4PXCCD60BS3HDB
4PXCDD60BS3HDB

BAYCONV30B

Figure 3

Figure 2

Remove
and 
Discard

Replace

NOTE:  

4PXC upflow coils may be installed in Upflow, Downflow, 

Horizontal Right with kit, and Horizontal Left with kit.

 

4PXC downflow coils may be installed in Downflow and 

Horizontal Right with kit.

2.    UPFLOW GAS FURNACE

a. Apply gasket material (duct seal field supplied) to ALL

    mating surfaces between the furnace and the coil case.
b. Set the coil case on top of the furnace. Connect the

    ductwork to the coil case using field supplied screws. 

See Figure 3.

c. Secure the coil case to the furnace and seal for air

    leaks as required.

2.     DOWNFLOW GASKET INSTALLATION (OPTIONAL): 

 For unusually humid applications that expect prolonged

 operation above 70% RH, it is recommended to use the

 BAYGSKT001A0 gasket kit to prevent water from forming

 on the bottom of the drain pan and dripping into the supply

 ductwork.

Summary of Contents for 4PXCAU24BS3HAB

Page 1: ... separately purchased kit Upflow models 4PXCAU24BS3HAB 4PXCAU32BS3HAB 4PXCBU24BS3HAB 4PXCBU30BS3HAB 4PXCCU30BS3HAB 4PXCBU36BS3HAB 4PXCCU36BS3HAB 4PXCBU42BS3HAB 4PXCCU42BS3HAB 4PXCBU48BS3HAB 4PXCCU48BS3HAB 4PXCDU48BS3HAB 4PXCCU60BS3HAB 4PXCDU60BS3HAB Downflow models 4PXCBD30BS3HDB 4PXCBD36BS3HDB 4PXCCD36BS3HDB 4PXCBD42BS3HDB 4PXCCD42BS3HDB 4PXCCD60BS3HDB 4PXCDD60BS3HDB NOTE OPTIONAL DOWNFLOW GASKET...

Page 2: ... coil is pressurized with 8 12 psig of dry air Do not stand directly in front of the coil connections when removing sealing plugs If no pressure is released check for leaks D FURNACE IN UPFLOW POSITION APPLICATION USES UPFLOW COIL MODELS ONLY IMPORTANT If installing the coil in the horizontal position you MUST use the horizontal kit listed below for this coil model num ber and follow the instructi...

Page 3: ...dischargeofrefrigeranttotheatmosphere 1 The following steps are to be considered when installing the refrigerant lines a Determine the most practical way to run the lines b Consider types of bends to be made and space limitations c Route the tubing making all required bends and properly secure the tubing before making final connections NOTE Refrigerant lines must be isolated from the structure and...

Page 4: ...g a strong water stream such as from a garden hose being careful to prevent fin damage Use chemical cleaners only when necessary Figure 6 Capillary tubes will come out the top of bulb when positioned correctly I CONDENSATE DRAIN PIPING Condensate drain connections are located in the drain pan at the bottom of the coil enclosure assembly The female threaded fitting protrudes outside of the enclosur...

Page 5: ...H C IN 13 5 8 13 5 8 16 5 8 16 5 8 20 1 8 16 5 8 20 1 8 23 5 8 20 1 8 23 5 8 TOP OPENING D 12 3 4 12 3 4 15 3 4 15 3 4 19 1 4 15 3 4 19 1 4 22 3 4 19 1 4 22 3 4 GAS CONNECTION 3 4 7 8 LIQUID CONNECTION 3 8 MATCHED FURNACE WIDTH NO ADAPTER RQUIRED 14 1 2 14 1 2 17 1 2 17 1 2 21 17 1 2 21 24 1 2 21 24 1 2 DRAIN PAN PLASTIC 4PXCCD36BS3 FIGURE A 42 17 5 8 17 1 2 16 5 8 15 3 4 3 4 17 1 2 4PXCCU30BS3 FI...

Page 6: ...6 18 AD41D1 1B EN Installer s Guide From Dwg D346711 RevB ...

Page 7: ... NO Is superheat 25F YES NO Is indoor temperature more than 85F NO Is sub cooling less than 8F YES Confirm that charge is correct and look for dirty or restricted outdoor coil Confirm that charge is correct NO Before starting insure the blower wheel indoor and outdoor coils are clean Is the liquid line temperature at indoor coil within 8F of outdoor liquid line temperature YES Verify line set is s...

Page 8: ...lications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice We are committed to using environmentally conscious print practices 2021 18 AD41D1 1B EN 27 Apr 2021 Supersedes 18 AD41D1 1A EN February 2021 ...