 18-AD42D1-1B-EN

Installer’s Guide

C. RECOMMENDATION

If a coil is part of the total system installation, use the Installer’s 
Guide packaged with the furnaces, outdoor sections, and  
thermostat for physically installing those components.

CAUTION

!

This coil is pressurized with 8-12 psig of dry air. Do not 

stand directly in front of the coil connections when  

removing sealing plugs. If no pressure is released, check 

for leaks. 

 

D. FURNACE IN UPFLOW POSITION

1.  UPFLOW COIL CONVERSION 

While not required, optional removal of some coil 

components will maximize airflow efficiency.

 

a.  Remove the coil by sliding the coil out of the coil  

enclosure.

 

b.  Optional for maximum efficiency: Remove the 

horizontal 

drain pan from the coil and discard.

 

c.  If present, remove the (2) outer water diverter baffles. 

See Figure 2.

2.  UPFLOW GAS FURNACE 
 

a.  Apply gasket material (duct seal field supplied) to ALL 

mating surfaces between the furnace and the coil case.

 

b.  Set the coil case on top of the furnace. Connect the 

ductwork to the coil case using field supplied screws.

 

c.  Secure the coil case to the furnace and seal for air 

leaks as required.

E. FURNACE IN DOWNFLOW POSITION

CAUTION

!

To prevent damage to pan, ensure Heat Shield is assembled 

to Horizontal Drain Pan. See Figure 8.

 

1.  DOWNFLOW COIL CONVERSION 

While not required, optional removal of some coil 

components will maximize airflow efficiency. 
a. Remove the coil by sliding the coil out of the coil 
    enclosure. 
b. Optional for maximum efficiency: Remove the horizontal 
    drain pan from the coil and discard.

2.  DOWNFLOW GASKET INSTALLATION (OPTIONAL) 

For unusually humid applications that expect prolonged 

operation above 70% RH, it is recommended to use the 

BAYGSKT001A0 gasket kit to prevent water from forming 

on the bottom of the drain pan and dripping into the 

supply ductwork. 
a. Lay the coil on its back side. 
b. Locate the 4" wide gasket material found in  

    BAYGSKT001A0. 
c. Attach the 4" gasket material to three sides of the  

    bottom of the drain pan as shown in Figure 4. Make  

    sure to start by matching up the edge of the gasket  

    material to the inner edge of the drain pan by the coil  

    fins and working outwards. 
d. The gasket material can be cut or ripped easily so that  

    it can be tailored to fit. The gasket material must cover  

    the three sides along the entire length of the coil as  

    shown in Figure 4.

FOR UPFLOW / 

HORIZONTAL LEFT 

INSTALLATIONS

Figure 3

UPFLO

W

FURNA

CE

CASED

COIL

SCREWS

(BOTH SIDES)

STANDOFFS

(BOTH SIDES)

STANDOFFS (4)

DRILL SCREWS (4)

Figure 4

Attach Downflow 

Bottom Gasket

Start 
here

3.  DOWNFLOW GAS FURNACE  

When a coil is used with a downflow furnace, a subbase 

is not required between the coil case and combustible 

flooring. 

 

a. Place the coil case on the furnace supply air plenum.

 

b. Secure the coil case to the plenum. 

 

c. Set the furnace on top of the coil case, making sure 

that the back side of the discharge opening is snug up 

against the duct flange at the top rear of the coil case.

 

d. Secure the coil case to the furnace and seal for air 

leaks as required.

Figure 2

WATER DIVERTER (X2)

Summary of Contents for 4TXCB004DS3HCC

Page 1: ...an expose you to chemicals including lead which are known to the State of California to case cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov A GEN...

Page 2: ...out of the coil enclosure b Optional for maximum efficiency Remove the horizontal drain pan from the coil and discard 2 DOWNFLOW GASKET INSTALLATION OPTIONAL For unusually humid applications that expe...

Page 3: ...out of the coil enclosure b When present remove the 2 outer water diverter baffles See Figure 2 2 Attach the coil and furnace in the orientation shown in Figure 6 For S Series furnaces bend flanges t...

Page 4: ...l and slide back into the coil cabinet c Bend rear tab on top baffle inward towards the coil to avoid interference with splash guard See Figure 12 d Wedge flange of Splash Guard between Channel for Sp...

Page 5: ...K CHECK 1 Using a manifold gauge connect an external supply of dry nitrogen to the gauge port on the liquid line 2 Pressurize the connecting lines and indoor coil to 150 PSIG maximum 3 Leak check braz...

Page 6: ...refrigerant or condensate lines Once the outer doors are removed the inner coil panels can be easily removed The inside and outside of the coil can be easily cleaned withabrushandvacuumwiththepanelsr...

Page 7: ...18 AD42D1 1B EN 7 Installer s Guide Outline Drawing for model 4TXCB004DS3HCC 4TXCD010DS3HCC From Dwg D346710 Rev A...

Page 8: ...NO Is superheat 25F YES NO Is indoor temperature more than 85F NO Is sub cooling less than 8F YES Confirm that charge is correct and look for dirty or restricted outdoor coil Confirm that charge is co...