2  

Service Facts

HAZARDOUS GASSES!
Exposure to fuel substances, or by-products of incomplete 
fuel combustion, is believed by the state of California to 
cause cancer, birth defects, or other reproductive harm.
This warning complies with State of California law, 
Proposition 65.
This product must be gas piped by a Licensed Plumber 
or Gas Fitter in the Commonwealth of Massachusetts.

SAFETY HAZARD!
Bodily injury can result from high voltage electrical 
components, fast moving fans, and combustible gas. For 
protection from these inherent hazards during installation 
and service, the electrical supply must be disconnected 
and the main gas valve must be turned off. If operating 
checks must be performed with the unit operating, it is 
the technicians responsibility to recognize these hazards 
and proceed safely.

SAFETY HAZARD!
This information is for use by individuals having adequate 
backgrounds of electrical and mechanical experience. 
Any attempt to repair a central air conditioning product 
may result in personal injury and/or property damage. 
The manufacturer or seller cannot be responsible for the 
interpretation of this information, nor can it assume any 
liability in connection with its use.

WARNING

!

SAFETY HAZARD!
Do not operate the unit without the evaporator fan or coil 
access panels in place. Reinstall the access panels after 
performing maintenance proceedures on the fan. Operat-
ing the unit without the access panels properly installed 
may result in severe personal injury or death.

EXPLOSION HAZARD!

Propane gas is heavier than air and may collect in any low 

areas or confined spaces. In addition, odorant fade may 

make the gas undetectable except with a warning device. 

If the gas furnace is installed in a basement, an excavated 

areas or a confined space, it is strongly recommended to 

contact a gas supplier to install a gas detecting warning 

device in case of leak. The manufacturer of your furnace 

does not test any detectors and makes no representations 

regarding any brand or type of detector.

CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER 
HIGH PRESSURE. RECOVER REFRIGERANT TO RE-
LIEVE PRESSURE BEFORE OPENING SYSTEM. Failure 
to follow proper procedures can result in personal illness 
or injury or severe equipment damage.

CAUTION

!

RECONNECT ALL GROUNDING DEVICES.
All parts of this product that are capable of conducting 
electrical current are grounded.  If grounding wires, screws, 
straps, clips, nuts, or washers used to complete a path to 
ground are removed for service, they must be returned to 
their original position and properly fastened.

Unit contains R-410A Refrigerant!

R-410A operating pressure exceeds the limit of R-22. Proper 

service equipment is required. Failure to use proper service 

tools may result in equipment damage or personal injury.

SERVICE

Use only R-410A Refrigerant and approved POE 

compressor oil.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

CAUTION

!

CAUTION

!

Summary of Contents for 4YCY4036B-SF-1H

Page 1: ...p Rise Min Max F Orifice Qty Drill Size Natural Gas POWER CONN V PH HZ Min Brch Cir Ampacity Fuse Size Max amps Fuse Size Recmd amps COMPRESSOR Volts Ph Hz R L Amps L R Amps OUTDOOR COIL TYPE Rows F P...

Page 2: ...maintenance proceedures on the fan Operat ing the unit without the access panels properly installed may result in severe personal injury or death EXPLOSION HAZARD Propane gas is heavier than air and...

Page 3: ...TE INDOOR WET BULB 2 FIND INTERSECTION OF OD TEMP ID W B 3 READ LIQUID 4 OR SUCTION 5 PRESSURE IN LEFT COLUMN EXAMPLE 1 OUTDOOR TEMP 82 F 2 INDOOR WET BULB 67 F 3 AT INTERSECTION ACTUAL 4 LIQUID PRESS...

Page 4: ...4 Service Facts IMPORTANT Retain this wiring diagram please return this document to service information pack upon completion of work...

Page 5: ...5 Service Facts IMPORTANT Retain this wiring diagram please return this document to service information pack upon completion of work...

Page 6: ...ame as above 2nd stage heat has a 10 minute delay from the time of 1st stage ignition Comfort Control satisfied Safety Sequences Thisproductisequippedwithsafetydevicestoprotectagainst abnormal conditi...

Page 7: ...0 5 0 6 0 7 0 8 0 9 1 Watts 169 182 210 243 273 301 331 370 433 480 530 CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 975 990 Watts 225 253 283 315 348 381 414 449 484 522 575 CFM 1187 1201 1203 1...

Page 8: ...uid Line Temperature and Refrigerant Pres sure at service valves in the compressor compartment 4 Locate your liquid line temperature in the left column of the table and the intersecting liquid line pr...

Page 9: ...9 Service Facts...

Page 10: ...High Suction Pressure Too Low Liquid Refrigerant floodback TXV System Liquid Refrig floodback Cap Tube System I D Coil Frosting Compressor Runs Inadequate or No Cooling Compressor O D fan Do Not Start...

Page 11: ...itch protection device open Steady ON Normal No Call for Heat 5 Flashes Flame sensed and gas valve not energized or flame sensed and no W signal 6 Flashes Flame Rollout Switch open 7 Flashes Thermosta...

Page 12: ...Trane 6200 Troup Highway Tyler TX 75707 01 13...