Product Specifications
MODEL
A801X026AM2SAC
A801X040AM3SAC
A801X040BM2SAC
TYPE
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
RATINGS
(a)
Input BTUH
26,000
40,000
40,000
Capacity BTUH (ICS)
(b) (c)
20,700
31,800
32,900
Temp. Rise (Min.-Max.)
25 - 55
30 - 60
30 - 60
AFUE (%)
80
80
80
Return Air Temp. (Min. - Max.)
55°F - 80°F
55°F - 80°F
55°F - 80°F
BLOWER DRIVE
DIRECT
DIRECT
DIRECT
Diameter — Width (In.)
11 X 8
11 X 8
11 X 8
No. Used
1
1
1
Speeds (No.)
(d)
9
9
9
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP
1/3
1/2
1/3
RPM
1075
1075
1075
Volts/Ph/Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
4.1
6.4
4.1
COMBUSTION FAN — Type
Centrifugal
Centrifugal
Centrifugal
Drive — No. Speeds
Direct - 1
Direct - 1
Direct - 1
Motor HP — RPM
3300
3300
3300
Volts/Ph/Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
1.39
1.39
1.39
FILTER — Furnished?
No
No
No
Type recommended
High Velocity
High Velocity
High Velocity
High Vel. (No.-Size-Thk.)
1 — 14x25 — 1 in.
1 — 14x25 — 1 in.
1 — 16x25 — 1 in.
VENT PIPE DIAMETER — Min (in.)
(e)
4 Round
4 Round
4 Round
HEAT EXCHANGER — Type
Aluminized Steel
Aluminized Steel
Aluminized Steel
Gauge (Fired)
20
20
20
ORIFICES — Main
Nat. Gas Qty. — Drill Size
2 - 51
2 - 45
2 - 45
GAS VALVE
Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage
PILOT SAFETY DEVICE
Type
120 V SiNi Igniter
120 V SiNi Igniter
120 V SiNi Igniter
BURNERS — QTY
2
2
2
POWER CONN. — V/Ph/Hz
(f)
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
Ampacity (Amps)
6.7
9.6
6.7
Max. Overcurrent Protection (Amps)
15
15
15
PIPE CONN. SIZE (in.)
1/2
1/2
1/2
(a)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
(b)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 — latest edition.
(c)
Based on U.S. government standard tests.
(d)
9 Speed constant torque ECM blower motor.
(e)
Refer to the Installer's Guide.
(f)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.