10
A801X-SVX001-1A-EN
MODEL
A801X080BM4SC
(a)
A801X080CM5SC
A801X100CM5SC
A801X120DM5SC
Type
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
RATINGS
(b)
Input BTUH
80,000
80,000
100,000
120,000
Capacity BTUH (ICS)
(c)
65,100
64,700
80,700
98,000
Temp. Rise (Min. - Max.) °F
30 - 60
30 - 60
30 - 60
35 - 65
AFUE - Rating
80
80
80
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
55°F - 80°F
55°F - 80°F
55°F - 80°F
BLOWER DRIVE
DIRECT
DIRECT
DIRECT
DIRECT
Diameter - Width (in.)
11 X 8
11 X 11
11 X 11
11 X 11
No. Used
1
1
1
1
Speeds (No.)
(d)
CTM - 9
CTM - 9
CTM - 9
CTM - 9
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP
3/4
1
3/4
1
R.P.M.
1050
1050
1050
1050
Volts / Ph / Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
9.2
10.9
10.9
10.9
COMBUSTION FAN - Type
PSC
PSC
PSC
PSC
Drive - No. Speeds
Direct - 1
Direct - 1
Direct - 1
Direct - 1
Motor RPM
3300
3300
3300
3300
Volts/Ph/Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
0.29
0.30
0.33
0.33
Inducer Orifice
1.75
1.80
2.50
2.15
FILTER - Furnished?
No
No
No
No
Type Recommended
High Velocity
High Velocity
High Velocity
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
1 - 20 X 25 - 1 in.
1 - 20 X 25 - 1 in.
1 - 24 X 25 - 1 in.
VENT PIPE DIAMETER - Min. (in.)
4 Round
4 Round
4 Round
4 Round
HEAT EXCHANGER - Type
Aluminized Steel
Aluminized Steel
Aluminized Steel
Aluminized Steel
Gauge (Fired)
20 - 19
20 - 19
20 - 19
20 - 19
ORIFICES - Main
Nat. Gas Qty. - Drill Size
4 - 45
4 - 45
5 - 45
6 - 45
L.P. Gas Qty. - Drill Size
4 - 56
4 - 56
5 - 56
6 - 56
GAS VALVE
Redundant - Single
Stage
Redundant - Single
Stage
Redundant - Single
Stage
Redundant - Single
Stage
PILOT SAFETY DEVICE - Type
120 V SiNi Igniter
120 V SiNi Igniter
120 V SiNi Igniter
120 V SiNi Igniter
BURNERS - QTY
4
4
5
6
POWER CONN. - V/Ph/HZ
(e)
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
Ampacity (Amps)
12.0
14.1
14.1
14.1
Max. Overcurrent Protection (Amps)
15
15
15
15
PIPE CONN. SIZE (IN.)
1/2
1/2
1/2
1/2
(a)
Central Furnace heating designs are certified to ANSI Z21.47 - latest edition.
(b)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 10,000 feet for elevations above 2,000 feet above sea level.
(c)
Based on U.S. government standard tests
(d)
9 Speed constant torque ECM Blower Motor.
(e)
The above wiring specifications are in accordance with National Electric Code, however, installations must comply with local codes.