UHM-DHM-SF-1H
7
Service Facts
24V Variable Speed
System Status
Setup Options
[ ] = Current Setting
CMFRT CNT MODE
COMM [24VAC] 24VAC
* Unit specific
A/TUHMB060
3T [3T] 1.5T 2T 2.5T
COOLING CFM
2
COOLING CFM
A/TUHMB080
3T [3T] 3.5T 2T 2.5T
*
A/TUHMC100
4T [4T] 2.5T 3T 3.5T
A/TUHMD120
5T [5T] 3.5T 4T
CFM PER TON
CFM PER TON
A/TDHMB060
3T [3T] 1.5T 2T 2.5T
400 [ 400 ] 430 450 290 310 330 350 370
A/TDHMB080
3T [3T] 3.5T 2T 2.5T
A/TDHMC100
4T [4T] 2.5T 3T 3.5T
CLG STAGES
CLG STAGES
A/TDHMD120
5T [5T] 3.5T 4T
1 STG [1 STG] 2 STGS
** Unit specific
CLG 1ST STG CFM
3
CLG 1ST STG CFM
2
A/TUHMB060
960 [960] 1080 830 900
50% [50%] 55% 65% 80%
A/TUHMB080
1400 [1400] 1610 1120 1260
A/TUHMC100
1620 [1620] 1790 1460 1540
CONT FAN CFM
CONT FAN CFM
A/TUHMD120
1890 [1890] 2000 1700 1790
50% [50%] 75% 100% 25%
A/TDHMB060
1040 [1040] 1160 900 950
A/TDHMB080
1400 [1400] 1610 1300 1350
FAN PRERUN DLY
FAN PRERUN DLY
A/TDHMC100
1650 [1650] 1700 1500 1600
NONE [NONE] 1m@50%
A/TDHMD120
1850 [1850] 2040 1660 1760
FAN SHRTRUN DLY
FAN SHRTRUN DLY
NONE [NONE] 4m@80% 7.5m@80%
FAN OFF DLY
FAN OFF DLY
1.5m@100% [1.5m@100%] NONE 1m@50% 2m@50% 3m@50%
HEAT CFM
HEAT CFM
**
HT OFF DELAY
HT OFF DELAY
100s [100s] 140 180 60
W1 W2 STG DLY
W1 W2 STG DLY
00m [00m] 5m 10m 15m
FACTORY DEFLTS
FACTORY DEFLTS
NO [NO] YES
EXIT
EXIT
NO [NO] YES
NOTES:
3
This menu will only display when 2 STGS is chosen in previous menu.
2
Shown only when Communicating Outdoor Unit is not detected
Summary of Contents for ADHMB060BCV3VA