background image

RT-SVN041B-EN

3

that must also be adhered to for responsible management of refrigerants.
Know the applicable laws and follow them.

W

WA

AR

RN

NIIN

NG

G

P

Prro

op

pe

err F

Fiie

elld

d W

Wiirriin

ng

g a

an

nd

d G

Grro

ou

un

nd

diin

ng

g R

Re

eq

qu

uiirre

ed

d!!

Failure to follow code could result in death or serious injury.
All field wiring MUST be performed by qualified personnel. Improperly
installed and grounded field wiring poses FIRE and ELECTROCUTION
hazards. To avoid these hazards, you MUST follow requirements for field
wiring installation and grounding as described in NEC and your local/state/
national electrical codes.

W

WA

AR

RN

NIIN

NG

G

P

Pe

errsso

on

na

all P

Prro

otte

eccttiiv

ve

e E

Eq

qu

uiip

pm

me

en

ntt ((P

PP

PE

E)) R

Re

eq

qu

uiirre

ed

d!!

Failure to wear proper PPE for the job being undertaken could result in
death or serious injury.
Technicians, in order to protect themselves from potential electrical,
mechanical, and chemical hazards, MUST follow precautions in this manual
and on the tags, stickers, and labels, as well as the instructions below:

Before installing/servicing this unit, technicians MUST put on all
PPE required for the work being undertaken (Examples; cut
resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/
bump cap, fall protection, electrical PPE and arc flash clothing).
ALWAYS refer to appropriate Safety Data Sheets (SDS) and OSHA
guidelines for proper PPE.

When working with or around hazardous chemicals, ALWAYS
refer to the appropriate SDS and OSHA/GHS (Global Harmonized
System of Classification and Labelling of Chemicals) guidelines
for information on allowable personal exposure levels, proper
respiratory protection and handling instructions.

If there is a risk of energized electrical contact, arc, or flash,
technicians MUST put on all PPE in accordance with OSHA, NFPA
70E, or other country-specific requirements for arc flash
protection, PRIOR to servicing the unit. NEVER PERFORM ANY
SWITCHING, DISCONNECTING, OR VOLTAGE TESTING
WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING.
ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY
RATED FOR INTENDED VOLTAGE.

IIn

nttrro

od

du

uccttiio

on

n

Summary of Contents for BAYDMPR310 Series

Page 1: ...d adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment July 2021 R RT T S SV VN N0 04 41 1B B E EN N Installation Guide Fresh Air Damper Used with Medium Foundation Light Commercial Rooftops M Mo od de el l N Nu um ...

Page 2: ...g stratospheric ozone layer when released to the atmosphere In particular several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine Fluorine and Carbon CFCs and those containing Hydrogen Chlorine Fluorine and Carbon HCFCs Not all refrigerants containing these compounds have the same potential impact to the environment Trane advocates the responsible...

Page 3: ...ST follow precautions in this manual and on the tags stickers and labels as well as the instructions below Before installing servicing this unit technicians MUST put on all PPE required for the work being undertaken Examples cut resistant gloves sleeves butyl gloves safety glasses hard hat bump cap fall protection electrical PPE and arc flash clothing ALWAYS refer to appropriate Safety Data Sheets...

Page 4: ...ore stringent than these policies those regulations supersede these policies Non Trane personnel should always follow local regulations Copyright This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part without written permission Trane reserves the right to revise this publication at any time and to make changes to its content without ...

Page 5: ... Im mp po or rt ta an nt t Do not proceed with installation of a damaged unit without sales representative s approval Visually inspect the complete exterior for signs of shipping damages to unit or packing material Verify that the nameplate data matches the sales order and bill of lading Verify that the unit is properly equipped and there are no material shortages Verify that the power supply comp...

Page 6: ... from receiving location Take photos of the damage if possible The owner must provide reasonable evidence that the damage did not occur after delivery Parts List Damper assembly O A cover panel Filter P Pr re e I In ns st ta al ll la at ti io on n ...

Page 7: ...d and damper panel to the unit outside air panel with 4 screws Remaining screws to be used in Step 2 5 Install the filter mist eliminator into the fresh air hood using the spring hinge to hold it in place as illustrated in Figure 1 p 7 6 Close the unit disconnect switch Figure 1 BAYDMPR310 damper assembly Mist Eliminator Hood and Panel Ship Attached Hinged Filter Access Motor Housing With 2 Positi...

Page 8: ... in Step 2 4 Adjust the damper blade to the desired position setting 5 Install the filter mist eliminator into the fresh air hood using the spring hinge to hold it in place as illustrated in Figure 2 p 8 6 Close the unit disconnect switch Figure 2 BAYDMPR311 damper assembly Hood and Panel Ship Attached Mist Eliminator Hinged Filter Access Manual Position Settings N No ot te e The filter mist elimi...

Page 9: ...RT SVN041B EN 9 Notes Notes ...

Page 10: ...10 RT SVN041B EN Notes ...

Page 11: ...RT SVN041B EN 11 Notes ...

Page 12: ... please visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice We are committed to using environmentally conscious print practices RT SVN041B EN 02 Jul 2021 Supersedes RT SVN041A EN June 2021 2021 ...

Reviews: