background image

CVHE-SVN01C-EN

16

General Information

Table 5. Typical  weights for cooling only

Shell Length Designators

Maximum Weights (Lbs)

Maximum Weights (Kg)

Type

Nton

EVSZ

CDSZ

Shipping

Operating

Shipping

Operating

CVHE

230-320

032S

032S

13191

14379

5983

6522

CVHE

230-320

032S

032L

13735

15018

6230

6812

CVHE

230-320

032L

032L

14381

15892

6523

7209

CVHE

230-320

050S

050S

16049

18000

7280

8165

CVHE

230-320

050S

050L

16864

18968

7650

8604

CVHE

230-320

050L

050L

17796

20259

8072

9189

CVHE

360-500

050S

050S

16699

18650

7575

8460

CVHE

360-500

050S

050L

17514

19618

7944

8899

CVHE

360-500

050L

050L

18446

20909

8367

9484

CVHE

360-500

080S

080S

22682

25797

10289

11702

CVHE

360-500

080S

080L

24025

27384

10898

12421

CVHE

360-500

080L

080L

25605

29497

11614

13380

CVHF

350-570

050S

050S

15694

17645

7119

8004

CVHF

350-570

050S

050L

16509

18613

7488

8443

CVHF

350-570

050L

050L

17441

19904

7911

9028

CVHF

350-570

080S

080S

21652

24767

9821

11234

CVHF

350-570

080S

080L

22995

26354

10431

11954

CVHF

350-570

080L

080L

24575

28467

11147

12913

CVHF

555-640

050S

050S

17314

19265

7854

8739

CVHF

555-640

050S

050L

18129

20233

8223

9178

CVHF

555-640

050L

050L

19061

21524

8646

9763

CVHF

555-640

080S

080S

23272

26387

10556

11969

CVHF

555-640

080S

080L

24615

27974

11165

12689

CVHF

555-640

080L

080L

26195

30087

11882

13647

CVHF

650-910

080S

080S

24242

27357

10996

12409

CVHF

650-910

080S

080L

25585

28944

11605

13129

CVHF

650-910

080L

080L

27165

31057

12322

14087

CVHF

1060-1280

142M

142L

35538

41116

16120

18650

CVHF

1060-1280

142L

142L

36352

42286

16489

19181

CVHF

1060-1280

142M

142L

36138

41716

16392

18922

CVHF

1060-1280

142L

142L

36952

42886

16761

19453

CVHF

1060-1280

142E

142L

37840

44303

17164

20096

CVHF

1060-1280

210L

210L

44666

52513

20260

23820

CVHF

1060-1280

250E

250L

54646

65616

24787

29763

CVHF

1470

210L

210L

49980

57820

22671

26227

CVHF

1470-1720

250E

250L

59960

70930

27198

32174

CVHG

480-565

050S

050S

18449

20400

8368

9253

CVHG

480-565

050S

050L

19264

21368

8738

9693

CVHG

480-565

050L

050L

20196

22659

9161

10278

CVHG

480-565

080S

080S

24432

27547

11082

12495

CVHG

480-565

080S

080L

25775

29134

11692

13215

CVHG

480-565

080L

080L

27355

31247

12408

14174

CVHG

670-780

080S

080S

25032

28147

11355

12767

CVHG

670-780

080S

080L

26375

29734

11964

13487

CVHG

670-780

080L

080L

27955

31847

12680

14446

CVHG

670-780

142M

142L

36627

42205

16614

19144

CVHG

920-1067

142L

142L

37441

43375

16983

19675

CVHG

920-1067

142M

142L

37427

43005

16977

19507

CVHG

920-1067

142L

142L

38241

44175

17346

20038

CVHG

920-1067

210L

210L

45955

53802

20845

24405

Summary of Contents for CenTraVac

Page 1: ...al Information Water Cooled CenTraVac With CH530 CVHE SVN01C EN X39640645030 Required Installation Information CVHE SVN01C EN General Information CVHE SVN02D EN Piping Information CVHE SVN03C EN Elect...

Page 2: ...ment damage Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions NOTICE Warnings and Cautions appear at appropriate sections throughout...

Page 3: ...nit Nameplate Metric Conversion Responsibilities of Installing Contractor s Unit Shipment Storage Recommended Unit Clearances Operating Environment Storage Requirements if Chiller is not installed Fou...

Page 4: ...ommended Lifting Arrangements 18 6 Isolation Pad 19 7 Isolation Spring Placement 21 8 Chiller Foot Isolator Orientation 22 9 Typical Spring Isolator Types and Construction 23 10 Checking Unit Levelnes...

Page 5: ...ical Engineers ASHRAE American Society of Heating Refrigerating and Air Conditioning Engineers BAS Building Automation System LBU La Crosse Business Unit CABS Auxiliary Condenser Tube Bundle Size CDBS...

Page 6: ...ahead of all pumps and automatic modulating valves 12 Supply and install pressure relief piping from pressure relief rupture disc to atmosphere 13 If necessary supply sufficient HCFC 22 refrigerant m...

Page 7: ...optional starter option only D Terminal lugs E Ground connection s F Jumper bars G BAS wiring optional H IPC wiring AFD and remote mounted starters only I Control voltage wiring AFD and remote mounted...

Page 8: ...verify that the correct unit was shipped to the job site 7 If a thorough inspection of the chiller reveals damage or material shortages be sure to file these claims with the carrier immediately Speci...

Page 9: ...nd the compressor shaft rotated 450 degrees Contact a qualified service organization to perform this task 8 If the chiller is stored for more than five years and the storage is expected to be indefini...

Page 10: ...g charges of refrigerant oil and water Table 2 and Table 3 give a summary of standard tube bundle locations Table 4 indicates the weights of various chiller options Table 5 shows typical weights for C...

Page 11: ...6 4724 15 6 4724 N A N A E L N A N A N A N A N A N A 17 5 5309 N A N A 17 5 5309 S S 26 5 8052 26 6 3 8 8087 27 4 1 4 8338 N A N A N A N A N A N A D S L M L L L 33 11 1 4 10343 34 10363 34 10 1 2 1064...

Page 12: ...4 N A N A E L N A N A N A N A N A N A 17 5 5309 N A N A N A N A S S 26 5 8052 26 6 3 8 8087 27 4 1 4 8338 N A N A N A N A N A N A D S L M L L L 33 11 1 4 10343 34 10363 34 10 1 2 10630 35 5 1 4 10801...

Page 13: ...SVN01C EN General Information Figure 4 Tube bundle locations showing cooling only free cooling and heat recovery and auxiliary condenser units Free Cooling Units Heat Recovery and Auxiliary Condenser...

Page 14: ...10 1 2 9 1 8 1 2 5 8 7 8 142 8 7 3 8 2 0 7 8 3 2 1 2 6 2 7 9 3 8 9 1 8 1 2 7 3 5 8 210 8 7 1 2 2 4 1 8 3 7 1 2 6 6 5 8 8 7 5 8 9 1 8 1 2 3 9 3 4 250 Not Available Table 4 Typical shipping and operati...

Page 15: ...5 1108 1997 2632 232 356 1162 250 Not Available Table 4 Typical shipping and operating weights k see note 1 Cond Size Aux Cond Size 80 Aux Cond Size 130 Heat Rec Cond Free Cooling CDSZ Ship Oper Ship...

Page 16: ...640 080S 080S 23272 26387 10556 11969 CVHF 555 640 080S 080L 24615 27974 11165 12689 CVHF 555 640 080L 080L 26195 30087 11882 13647 CVHF 650 910 080S 080S 24242 27357 10996 12409 CVHF 650 910 080S 080...

Page 17: ...en remove the eyebolt that was used to secure the safety chain to the compressor and reinstall the retaining colt in its place If the chiller cannot be moved using the conventional rigging method just...

Page 18: ...nt or property only damage Failure to properly lift unit may result in death or serious injury See details below WARNING Improper Unit Lift Test lift unit approximately 24 inches to verify proper cent...

Page 19: ...19 CVHE SVN01C EN General Information...

Page 20: ...n Isolation Pads When the unit is ready for final placement position isolation pads end for end under the full length of the chiller leg The pads measure 6 18 152 4x457 mm and on some units there may...

Page 21: ...7 15173 6882 CVHF 555 640 080S 080L 12614 5722 15360 6967 CVHF 555 640 080L 080L 12876 5841 17211 7807 CVHF 650 910 080S 080S 11835 5368 15522 7041 CVHF 650 910 080S 080L 13233 6002 15711 7127 CVHF 65...

Page 22: ...CVHE SVN01C EN 22 General Information Figure 7 Isolation spring placement...

Page 23: ...ator However do not allow the screws to protrude below the underside of the isolator upper housing An alternative method of fastening the chiller to the isolators is to cement the neoprene pads 5 Set...

Page 24: ...ing Bolt 6 1 2 165 mm Free Height Adjust the isolator so that the upper housing clears the lower housing by at least 1 4 6 mm Acoustical nonskid neoprene pad top and bottom 5 8 16 mm 4 X 88 22mm Dia H...

Page 25: ...1 B UNC Adjusting and Leveling Bolts Figure 9 continued Typical spring isolator types and construction Type CT 7 Spring Isolators Isolator Maximum Spring Type Load Deflection Color and Size lbs Inches...

Page 26: ...ttom 2 1 5 8 28 5 mm 7 Unc Adjusting Leveling Bolts 7 1 2 190 5 mm Figure 9 continued Typical spring isolator types and construction Isolator Maximum Spring Type Load Deflection Color and Size lbs Inc...

Page 27: ...h water until the level aligns with the punch mark at one end of the chiller then check the water level at the opposite mark If the water level does not align with the punch mark use full length shims...

Page 28: ...ntinuous product and product data improvement and reserves the right to change design and specifications without notice Only qualified technicians should perform the installation and servicing of equi...

Reviews: