58
CVHH-SVX001G-EN
Power Supply Wiring
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
X39003892001A
N
No
otte
e:: Graphic labels (shown above) are used for CE
application only.
IIm
mp
po
orrtta
an
ntt::
•
Before servicing, disconnect all power
sources and allow at least 30 minutes
for capacitors to discharge.
•
All electrical enclosures—unit or remote
—are IP2X.
Three-Phase Power
Review and follow the guidelines in this section to
properly install and connect the power supply wiring to
the starter panel:
•
Verify that the starter nameplate ratings are
compatible with the power supply characteristics
and with the electrical data on the unit nameplate.
N
NO
OT
TIIC
CE
E
A
Ad
da
ap
pttiiv
ve
e F
Frre
eq
qu
ue
en
nccy
y D
Drriiv
ve
e ((A
AF
FD
D))//
S
Stta
arrtte
err C
Co
om
mp
po
on
ne
en
ntt D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o rre
em
mo
ov
ve
e d
de
eb
brriiss ffrro
om
m iin
nssiid
de
e tth
he
e A
AF
FD
D//
sstta
arrtte
err p
pa
an
ne
ell cco
ou
ulld
d rre
essu
ulltt iin
n a
an
n e
elle
eccttrriicca
all ssh
ho
orrtt a
an
nd
d
cco
ou
ulld
d cca
au
usse
e sse
erriio
ou
uss A
AF
FD
D//sstta
arrtte
err cco
om
mp
po
on
ne
en
ntt
d
da
am
ma
ag
ge
e..
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
•
Do NOT modify or cut enclosure to provide
electrical access. Removable panels have been
provided and any modification should be done
away from the enclosure. If the starter enclosure
must be cut to provide electrical access, exercise
care to prevent debris from falling inside the
enclosure.
•
Use copper conductors to connect the three-phase
power supply to the remote- or unit-mounted
starter panel.
•
Flexible conduit connections are recommended to
enhance serviceability and minimize vibration
transmission.
•
Size the power supply wiring in accordance with
National Electric Code (NEC) and local guidelines,
using the RLA value stamped on the chiller
nameplate and transformer load on L1 and L2.
•
Confirm that wire size is compatible with lug size
stated in unit submittal.
•
Make sure that the incoming power wiring is
properly phased; each power supply conduit run to
the starter must carry the correct number of
conductors to ensure equal phase representation.
N
No
otte
e:: Connect L1, L2, and L3 (shown in the
following figure) per starter diagram
provided with chiller.
•
When installing the power supply conduit, ensure
that the position of the conduit does not interfere
with the serviceability of any of the unit
components, or with structural members and
equipment. Ensure that the conduit is long enough
to simplify any servicing that may be necessary in
the future (e.g., starter).
•
Electrical wire torque specifications—follow starter
manufacturer’s torque specifications.
Summary of Contents for CVHH CenTraVac