background image

 

32-5035-13

User’s Information

Lighting instructions.

Your furnace does not use a continuously burning pilot 
flame. Therefore, manually lighting your furnace is not 
required.  Your  furnace  is  equipped  with  an  automatic 
ignition  system.  It    uses  a  hot  surface  ignition  device 
that  automatically  lights  the  burners  each  time  the 
comfort control signals the furnace to start. 

WARNING

!

buRN HAZARD

DO  NOT  ATTEMPT  TO  MANuALLy  LIGHT  THE  FuR-

NACE.   

FAILuRE TO  FOLLOW THIS WARNING  COuLD 

RESuLT  IN  PROPERTy  DAMAGE,  PERSONAL  INjuRy 

OR DEATH.

CAuTION

!

If  the  furnace  is  shut  down  during  the  cold  weather 

months, provisions must be taken to prevent freeze-up 

of all water pipes and water receptacles.

  1.  Please read all safety information in this book be-

fore operating furnace.

  2.  Set  comfort  control  to  lowest  setting.  Turn  off  all 

electric power to furnace.

  3.  Remove  the  furnace  front  panel  to  gain  access  to 

the main gas valve.

  4.  Turn  external  main  gas  shutoff  valve  or  the  tog-

gle  switch  located  on  the  main  gas  valve  inside 
the unit  to the “OFF” position (see illustration on 
this  page).  If  an  external  main  gas  shutoff  valve 
is  used,  turn  to  “OFF”  position  (see  illustration 
on next page). Allow 5 minutes for any gas within 
the  unit  to  escape.  LP  gas  being  heavier  than  air 
may  require  forced  ventilation. 

If  you  smell  gas 

STOP!  Follow  the  “What  To  Do  If  You  Smell 
Gas”  instructions  on  the  front  cover  of  this 
book. If you don’t smell gas, go to next step.

To Start the Furnace

your furnace will have a switch to turn the gas ON or OFF.

  5.  Turn  the  external  main  gas  shutoff  valve  and  the 

toggle switch located on the main gas valve inside 
the  unit  to  the  “ON”  position  (see  illustration  on 
this page). 

  6.  Replace the furnace front access panel.
  7.  Turn  on  main  electrical  supply  and  set  comfort 

control to desired setting. Combustion blower will 
start and ignition device will start to heat up. After 
approximately 15 seconds main gas valve will open 
and burners will ignite.

  8.  When  the  comfort  control  is  satisfied,  main  burn-

ers will extinguish.

  9.  If  main  burners  fail  to  ignite  turn  off  the  main 

electrical  supply  power  or  lower  the  comfort  con-
trol setting and wait 5 minutes. 

 10. Raise the comfort control setting and restore elec-

trical supply power. Repeat steps 6 through 8.

 11.  If  furnace  still  will  not  light,  turn  “OFF”  all  gas 

and electricity to unit and call servicer or gas sup-
plier.

For complete shutdown.

Turn the external main gas shutoff valve and the tog-
gle switch on the main gas valve inside the unit to the 
“OFF” position. Disconnect electrical supply to unit.

CAuTION

!

Whenever your house is to be vacant, arrange to have 

someone inspect your house for proper temperature. If 

precautions are not taken, damage could result, such 

as frozen water pipes. 

Flame Roll-out Device.

All models are equipped with a manual resetting roll-
out  switch  located  near  the  burners.  In  case  of  flame 
roll-out,  the  switch  trips  automatically  shutting  off 
all flow of gas.  The switch must be manually reset by 
pressing the red reset button on the top of the switch.

Gas valve On / Off 
Toggle Switch

On/Off Switch

Summary of Contents for DD-ACV

Page 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Page 2: ...iate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gentl...

Page 3: ...Also air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area w...

Page 4: ...Start the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON pos...

Page 5: ...ny questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GA...

Page 6: ...er a BOTTOM or SIDE left or right return air inlet The filter may be secured with filter retaining brackets as shown or a filter rack To clean or replace filters remove blower access door slide the fi...

Page 7: ...n both top and bot tom filter brackets Replace filter access door REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS...

Page 8: ...r syn thetic solvents may damage the finish DOWNFLOW Vertical FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 2 14 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1 DOWNF...

Page 9: ...so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace f The burner flames are in good adjustment without erratic flames See illustation...

Page 10: ...corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned annu ally for best operation 6 CIRCUIT PROTECTION If blower or gas valve fail to...

Page 11: ...the gas furnace is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance wit...

Page 12: ...d then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective This limited warranty does not apply if the gas furnace was purchased direct i e fr...

Page 13: ..._________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________...

Page 14: ...hange design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor File name 32 5035 13 Supersedes 32 5035 12 Date 10 09...