User’s Information

For vertical UPFLOW ONLY, a left or right return air 
inlet  as  above  (left  side  shown)  requires  trimming  of 
the factory supplied filter to 17" x 25" x 1" for both the 
21" and 24-1/2" wide furnaces.
Air  filters  may  also  be  located  outside  of  the  furnace 
using a 

SIDe FIlTeR FRAme.

upflow/ Horizontal Furnace Filters

The  Upflow/  Horizontal  furnace  when  installed  hori-
zontally requires a horizontal filter kit. The filters may 
be  located  remote  to  the  furnace  or  in  the  return  air 
duct near the furnace. Check with your dealer for the 
location of your filters.
An  upflow/horizontal  furnace  in  horizontal  return  air 
filter  application,  as  shown,  features  two  16"  x  20"  x 
1"  filters  in  the  17-1/2",  21"  and  24-1/2"  wide  furnace 
cabinets.
To replace filters, remove the filter access door, lift the 
filter from the lower bracket and shift the filter to the 
side to free the top filter from the bracket and slide the 
filters out through the filter access door. After cleaning, 
replace  the  filters  in  the  same  manner  making  sure 
that the filters are secured in place in both top and bot-
tom filter brackets. Replace filter access door.

REquIRED FILTERS - bOTTOM

CAbINET WIDTH

FILTER quANTITy & SIZE

17-1/2"

1 - 17" X 25" X  1"

21"

1 - 20" X 25" X  1"

24-1/2"

1 - 24" X 25" X  1"

REquIRED FILTERS - SIDE  **

CAbINET WIDTH

FILTER quANTITy & SIZE

17-1/2"

1 - 17" X 25" X  1"

21"

1 - 17" X 25" X  1"

24-1/2"

1 - 17" X 25" X  1"

** ON UPFLOW 5 TON AIRFLOW MODELS, IF THE AIR-

FLOW REQUIREMENT EXCEEDS 1800 CFM, THESE 

MODELS WILL REQUIRE FILTERS ON BOTH SIDES 

OR

 

1 SIDE AND THE BOTTOM, 

OR

 JUST THE BOTTOM

uPFLOW  

ONLy

Airflo

w

DOWNFLOW FILTER

Airflow

uPFLOW/HORIZONTAL WITH FILTER KIT

Airflow

Air  filters  may  also  be  located  outside  of  the  furnace 
using a remote filter grille

The filter grille could be in 

a hallway, wall, or in the ceiling. Check with your deal-
er for the exact location of your filter and the method 
of changing the filters.

uPFLOW (vertical) FILTER TAbLES

Downflow/  Horizontal  furnaces  are  factory  supplied 
with 2 standard size permanent type air filters which 
may be located remote to the furnace or in the return 
air  duct.    Check  with  your  dealer  for  the  location  of 
your filters.
A downflow/ horizontal furnace return air filter appli-
cation, as shown, features two 14" x 20" x 1" filters in 
the 17-1/2" wide furnace cabinets; or two 16" x 20" x 1" 
filters in the 21" and 24-1/2" wide furnace cabinets.

Summary of Contents for DD-ACV

Page 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Page 2: ...iate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gentl...

Page 3: ...Also air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area w...

Page 4: ...Start the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON pos...

Page 5: ...ny questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GA...

Page 6: ...er a BOTTOM or SIDE left or right return air inlet The filter may be secured with filter retaining brackets as shown or a filter rack To clean or replace filters remove blower access door slide the fi...

Page 7: ...n both top and bot tom filter brackets Replace filter access door REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS...

Page 8: ...r syn thetic solvents may damage the finish DOWNFLOW Vertical FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 2 14 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1 DOWNF...

Page 9: ...so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace f The burner flames are in good adjustment without erratic flames See illustation...

Page 10: ...corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned annu ally for best operation 6 CIRCUIT PROTECTION If blower or gas valve fail to...

Page 11: ...the gas furnace is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance wit...

Page 12: ...d then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective This limited warranty does not apply if the gas furnace was purchased direct i e fr...

Page 13: ..._________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________...

Page 14: ...hange design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor File name 32 5035 13 Supersedes 32 5035 12 Date 10 09...

Reviews: