UH1-DH1-SF-1L
Service Facts
3
PRODUCT SPECIFICATIONS
1
MODEL
TYPE
RATINGS
2
Input BTUH
3
Capacity BTUH (ICS)
3
Temp. rise (Min.-Max.) °F.
AFUE
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT PIPE DIAMETER —
Min (In.)
56
HEAT EXCHANGER
Type - Fired
- Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection
(Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
*DH1B065A9421C
Downflow / Horizontal
60,000
57,000
25 - 55
95.0
DIRECT
11 x 8
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/25 - 3200
115/1/60
1.35
No
High Velocity
2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
4 — 48
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
11.4
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 148
*DH1D110A9601C
Downflow / Horizontal
110,000
104,500
35 - 65
95.0
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
2 - 16x20 - 1in.
2.5 Round
Aluminized Steel - Type I
20
6 — 48
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
6
115/1/60
12.9
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
205 / 193
*DH1C085A9481C
Downflow / Horizontal
80,000
76,000
30 - 60
95.0
DIRECT
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
2 - 16x20 - 1in.
2.5 Round
Aluminized Steel - Type I
20
5 — 48
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
12.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
171 / 160
Notes
1
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5
Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.
6
All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
*DH1B040A9241C
Downflow / Horizontal
40,000
38,000
30 - 60
95.0
DIRECT
10 x 7
1
4
See Fan Performance Table
1/5
1080
115/1/60
Centrifugal
Direct - 1
1/55 - 3000
115/1/60
1.14
No
High Velocity
2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 45
2 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
2
115/1/60
4.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
145 / 135
Summary of Contents for DH1B040A9241C Series
Page 6: ...6 UH1 DH1 SF 1L Service Facts continued on next page WIRING DIAGRAM From Dwg D345803P01 Rev A...
Page 7: ...UH1 DH1 SF 1L Service Facts 7 SCHEMATIC DIAGRAM From Dwg D345803P01 Rev A...
Page 8: ...8 UH1 DH1 SF 1L Service Facts continued on next page WIRING DIAGRAM From Dwg D345804P01 Rev A...
Page 9: ...UH1 DH1 SF 1L Service Facts 9 SCHEMATIC DIAGRAM From D345804P01 Rev A...
Page 18: ...18 UH1 DH1 SF 1L Service Facts...