background image

Introduction

ACC-SVN232A-EN

Copyright

This document and the information in it are the property of 
Trane, and may not be used or reproduced in whole or in 
part without written permission. Trane reserves the right 
to revise this publication at any time, and to make changes 
to its content without obligation to notify any person of 
such revision or change.

Trademarks

All trademarks referenced in this document are the 
trademarks of their respective owners. 

WARNING

Follow EHS Policies!

Failure to follow instructions below could result in 
death or serious injury.

All Trane personnel must follow the company’s 
Environmental, Health and Safety (EHS) policies 
when performing work such as hot work, electrical, 
fall protection, lockout/tagout, refrigerant handling, 
etc. Where local regulations are more stringent than 
these policies, those regulations supersede these 
policies. 

Non-Trane personnel should always follow local 
regulations.

Summary of Contents for FIAECON003 Series

Page 1: ...nstall and service the equipment The installation starting up and servicing of heating ventilating and air conditioning equipment can be hazardous and requires specific knowledge and training Improper...

Page 2: ...rdous situation which if not avoided could result in minor or moderate injury It could also be used to alert against unsafe practices NOTICE Indicates a situation that could result in equipment or pro...

Page 3: ...arks All trademarks referenced in this document are the trademarks of their respective owners WARNING Follow EHS Policies Failure to follow instructions below could result in death or serious injury A...

Page 4: ...recedent 5 Field Installed Option 5 Factory Installed Option 5 Installation Precedent 6 Field Installed Option 6 Factory Installed Option Field Set Up 8 Mist Eliminator Servicing 9 Minimum Position Se...

Page 5: ...provide reasonable evidence that the damage did not occur after delivery 6 Notify the carrier s terminal of damage immediately by phone and by mail Request an immediate joint inspection of the damage...

Page 6: ...ves from potential electrical mechanical and chemical hazards MUST follow precautions in this manual and on the tags stickers and labels as well as the following instructions Unless specified otherwis...

Page 7: ...post flange as illustrated in following figure c Position the left side flange on the economizer in front of the corner post flange d With the screws provided secure the bottom right hand side of the...

Page 8: ...Figure 12 7 With the screws provided secure each side of the economizer assembly by inserting a screw through the clearance hole in the bottom of the corner post and into the engagement hole in the e...

Page 9: ...screws provided 11 Using field supplied silicone sealant seal all seams cracks and gaps around the back panel and vertical edge of the hood panels Mist Eliminator Servicing 1 Remove screws from end p...

Page 10: ...made using the Symbio service and installation mobile app or Symbio 700 on board UI Wiring Connections Refer to main unit schematic sheet 6 for electrical connections to Fresh air module located in re...

Page 11: ...Notes ACC SVN232A EN 11...

Page 12: ...gn and specifications without notice We are committed to using environmentally conscious print practices Trane and American Standard create comfortable energy efficient indoor environments for commerc...