3

Section 1. Safety Information

WARNING

!

SAFETY HAzARD! 

This information is intended for use 

by individuals possessing adequate backgrounds of electrical and 
mechanical experience. Any attempt to repair a central air condition-
ing product may result in personal injury and/or property damage. 
The manufacturer or seller cannot be responsible for the interpreta-
tion of this information, nor can it assume any liability in connection 
with its use.

LIVE ELECTRICAL COMPONENTS! 

During instal-

lation, testing, servicing, and troubleshooting of this product, it may 
be necessary to work with live electrical components. Failure to fol-
low all electrical safety precautions when exposed to live electrical 
components could result in death or serious injury.

CAUTION

!

WARNING

!

CORROSION HAzARD! 

To prevent shortening its service 

life, the air handler should not be used during the finishing phases 
of construction. The low return air temperatures can lead to the 
formation of condensate. Condensate in the presence of chlorides 
and fluorides from paint, varnish, stains, adhesives, cleaning com-
pounds, and cement creates a corrosive condition which may cause 
rapid deterioration of the cabinet and internal components.

Important: 

Due to the unique design of this unit, which 

allows the electrical wiring to be routed within the insula-
tion, do not screw, cut, or otherwise puncture the unit 
cabinet in any location other than the ones illustrated in 
this Installer Guide or in an approved accessory’s In-
staller Guide.

Important: 

Under no conditions should metal strapping 

be attached to the unit to be used as support mecha-
nisms for carrying or suspension purposes.

SAFETY HAzARD! 

Sharp Edge Hazard. Be careful of sharp 

edges on equipment or any cuts made on sheet metal while install-
ing or servicing. Personal injury may result.

CAUTION

!

CAUTION

!

HAzARDOUS VAPORS! 

Do not install an air handler 

with a non-ducted return in the same closet, alcove, or utility 
room as a fossil fuel device. Hazardous vapors can be distributed 
throughout the conditioned space and equipment damage can 
result.

Summary of Contents for GAM5 Series

Page 1: ...R I approved matched indoor and outdoor systems Some of the benefits of installing approved matched indoor and outdoor split systems are maximum efficien cy optimum performance and the best overall s...

Page 2: ...ection 9 Connecting the Duct work 21 Section 10 Refrigerant Line 22 Section 11 Refrigerant Line Brazing 23 Section 12 Condensate Drain Piping 26 Section 13 Electrical Low Voltage 28 Section 14 Electri...

Page 3: ...an lead to the formation of condensate Condensate in the presence of chlorides and fluorides from paint varnish stains adhesives cleaning com pounds and cement creates a corrosive condition which may...

Page 4: ...only in the first 3 4 of front bottom of unit in cross member Important Due to the unique design of this unit which allows the electrical wiring to be routed within the insulation do not screw cut or...

Page 5: ...cabinet 3 Pull panel down and out of channel 4 Set aside To remove Heater Panel 1 Turn screws on Heater panel 2 Pull panel straight out away from cabinet 3 Set aside Removal of the Line Set panel is r...

Page 6: ...8kW Breaker 24V Control 1 Ph A to C BAYEAAC08LG1A Electric Heater 8kW Lugs 24V Control 1 Ph A to C BAYEAAC10BK1A Electric Heater 10kW Breaker 24V Control 1 Ph A to C BAYEAAC10LG1A Electric Heater 10kW...

Page 7: ...position it must be laid on its back marked REAR on carton Note To reassemble cabinet follow the steps in reverse order Ensure electrical connections are secure and the plug clips are engaged 4 1 Dis...

Page 8: ...pread the top of the diverter slightly outwards and then pulling down and out through the blower opening as illustrated STEP 2 Disconnect the two wiring connections routed to the blower assembly STEP...

Page 9: ...those wire harnesses STEP 6 Slide Coil assembly out of unit using built in coil support channels and set aside STEP 7 Use a 5 16 Allen wrench on the locking mechanism on each side of the bottom half...

Page 10: ...10 1 2 STEP 8 Lift the Coil section up and away from the Blower section Set aside...

Page 11: ...emove the top panel and all cross members Use a manual driver to avoid stripping screw holes Note Cross Members are removed by rotating them toward the door opening and then lifting up and out of the...

Page 12: ...ions should metal strap ping be attached to the unit to be used as support mechanisms for carrying or suspension purposes Approved carrying 1 Hold by the cross members within the cabinet or unit top p...

Page 13: ...nd Weight Model Number H x D x W in Blower Compartment in Unit Net Weight lbs GAM5A0A18H21SAA 50 x 22 x 17 1 2 22 120 GAM5A0A24H21SAA 50 x 22 x 17 1 2 22 120 GAM5B0A30H31SAA 52 x 22 x 21 22 133 GAM5B0...

Page 14: ...ctory suitable for four way conversion They are shipped in the down flow orientation 6 2 Four Way Conversion Upflow Condensate Drains Refrigerant Connections Downflow Condensate Drains Downflow Config...

Page 15: ...izontal Left Condensate Drains Low Voltage Connections inside unit Refrigerant Connections Horizontal Left Configuration Low Voltage Connections inside unit Horizontal Right Condensate Drains Airflow...

Page 16: ...ve or utility room Review local codes to determine limitations if the unit is installed without a return air duct Ducted Return Non Ducted Return Supply Duct Plenum Accessory with safety guard CAUTION...

Page 17: ...access for refrigerant lines Consider the overall space needed when external accessories are used additional height and width requirements may exist These units are not approved for outdoor installati...

Page 18: ...to support the total weight of the unit accessories and duct work must be provided Isolate unit from the foundation using a suitable isolating material Typical Closet Installation 7 2 Upflow Installat...

Page 19: ...The air handlers are rated for zero clearance from combustible materials STEP 1 Prepare the location site as appropriate for your application and per national state and local code requirements STEP 2...

Page 20: ...Due to the unique design of this unit which allows the electrical wiring to be routed within the insulation do not screw cut or otherwise puncture the unit cabinet in any location other than the ones...

Page 21: ...the air handler Reference ACCA Manual D Manual S and Manual RS along with the air handler Product Data and Service Facts for additional information Note Side return is not approved without Side Return...

Page 22: ...n Sizes Model Vapor Line Connection Liquid Line Connection GAM5A0A18H21SAA 3 4 3 8 GAM5A0A24H21SAA 3 4 3 8 GAM5B0A30H31SAA 3 4 3 8 GAM5B0A36H31SAA 7 8 3 8 GAM5C0A42H41SAA 7 8 3 8 GAM5C0A48H41SAA 7 8 3...

Page 23: ...rant connec tion stubs until ready to make connections STEP 2 Remove the plastic cap and Schrader valve core from the gas line STEP 3 Wrap the vapor sensor with a wet rag Important Care must be taken...

Page 24: ...line 2 Wrap the Vapor Sensor with wet rag 3 Braze the refrigerant line connections Important Care must be taken during solder cap removal and brazing to avoid damage to unit compo nents STEP 8 Pressu...

Page 25: ...es and indoor coil leak check and evacu ation are complete STEP 10 Evacuate until the micron gauge reads no higher than 350 microns then close off the valve to the vacuum pump STEP 11 Observe the micr...

Page 26: ...r draining STEP 3 Connect 3 4 PVC pipe to the primary drain connection and the secondary drain connection if used using threaded drain nipples Use Teflon tape on the air handler drain line con nection...

Page 27: ...oint temperatures may be met Optional depending on climate and application needs Provide a means of drainage to prevent winter freeze up of condensate line Optional depend ing on climate and applicati...

Page 28: ...and to the thermostat Table 11 1 24 VOLTS WIRE SIZE MAX WIRE LENGTH 18 AWG 150 Ft 16 AWG 225 Ft 14 AWG 300 Ft 13 2 Low Voltage Hook up Instructions STEP 1 Route control wiring to unit Remove the exter...

Page 29: ...nly Remove the control board completely from the control pocket Rotate the control board180 degrees Place the control board 4 6 inches back into the con trol pocket Attach wiring per appropriate hook...

Page 30: ...er W1 W2 and W3 together if comfort control has only one stage of heat R to O jumper must be in place as shown for cooling only non heat pump systems for proper operation YI andYO connections must be...

Page 31: ...Blue Black X2 Red Orange Heat Pump Red Yellow Orange Green White Blue Yellow Green White Blue B B Blue W G Y Y Yellow R Red O Orange O R B YI W1 YO G W2 W3 R Red O Orange W1 White SW1 410 22 1 2 3 SW1...

Page 32: ...res are located within the wire pass through pro vided in the panel STEP 7 Slide control plate assembly into the control pocket until fully seated The control plate should be flush with the outer edge...

Page 33: ...Connections STEP 1 Route High Voltage wiring to unit STEP 2 Select a conduit entry point 1 Select the entry point you will use to bring in your high voltage wiring 2 Remove plug from the entry point L...

Page 34: ...or 1 1 2 conduit to conduit nut Note Reducing bushings may be required for your application STEP 4 Connect L1 L2 and ground wiring to pigtail harness and single green ground in Heater Compartment usin...

Page 35: ...Filter Size 16 x 20 20 x 20 22 x 20 Cabinet size is indicated by the 7th digit in model number Table 16 1 Filter Sizes 15 1 Remove the blower door panel Section 15 Time Delay Switch Adjustment Set the...

Page 36: ...36 Section 17 Unit Outline Drawing...

Page 37: ...A6H5060E1 4A6B4061E1 4A6H5061E1 All other non rated matches must be charged per the nameplate charging instructions The following combinations should be charged to 8 degrees sub cooling to maintain ra...

Page 38: ...ower disconnect s to apply power to the indoor and outdoor units STEP 4 Set the system thermostat to ON OFF DONE CANCEL ON OFF ON DONE CANCEL STEP 1 Make sure all panels are securely in place and that...

Page 39: ...O terminal signals the EVC that the unit is in heat pump heating mode 4 Normally closed contacts on the EVC will pass 24VAC to the Yo terminal providing power to the outdoor unit control circuit 5 Th...

Page 40: ...8 Be sure that the correct airflow setting is used Indoor Blower Motor 9 Operate complete system in each mode to verify proper performance Verify operation of supplemen tary electric heater Final pha...

Reviews: