TWE Product Specifications
Model
TWE030CA40B
TWE040CA40C
TWE050CA50D
Power Conn.— Volts/Ph/Hz
220/1/50
220/1/50
220/1/50
Indoor Coil - Type
Plate Fin
Plate Fin
Plate Fin
Rows
3
3
3
Fins per inch (Fins per 25.4 mm)
14
14
14
Face Area sq ft (sq m)
3.21 (.30)
5.04 (.47)
6.19 (.58)
Tube Size in. (mm)
3/8 (9.52)
3/8 (9.52)
3/8 (9.52)
Refrigerant Control
FCCV
FCCV
FCCV
Drain Conn. Size in. (mm)
3/4 NPT
3/4 NPT
3/4 NPT
Duct Connections
See Outline Drawing
See Outline Drawing
See Outline Drawing
Indoor Fan - Type
Centrifugal
Centrifugal
Centrifugal
No. Used
1
1
1
Diameter in. (mm)
10.0 (254.0)
10.0 (254.0)
11.0 (279.4)
Width in. (mm)
8.0 (203.2)
10.0 (254.0)
10.0 (254.0)
Type Drive - No. Speeds
Direct - 3
Direct - 3
Direct - 3
Airflow (High)
CFM @ 0.0 in. w.g.
See Fan Performance Table
See Fan Performance Table
See Fan Performance Table
CMH @ 0.0 Pa
See Fan Performance Table
See Fan Performance Table
See Fan Performance Table
No. Motors - HP
1 - 1/3
1 - 1/3
1 - 3/4
Motor RPM
1000
900
900
Volts/Ph/Hz
220/1/50
220/1/50
220/1/50
F.L. Amps
2.6
2.1
4.5
L.R. Amps
3.3
4.2
10.1
Filters
Vertical Applications
Filter Furnished
Yes
Yes
Yes
Type Furnished
Throwaway
Throwaway
High Velocity
No.-Size-Thickness
1 - 20 x 20 - 1
1 - 20 x 20 - 1
1 - 2 2 x 20 - 1
Horizontal Applications
Filter Furnished
No
No
No
Type Recommended
See Note Below
See Note Below
See Note Below
No.-Size-Thickness
See Note Below
See Note Below
See Note Below
Refrigerant Line Size
Line Size ID Gas in. (mm)
7/8 (22.23)
1-1/8 (28.56)
1-1/8 (28.56)
Line Size ID Liquid in. (mm)
3/8 (9.52)
3/8 (9.52)
3/8 (9.52)
Dimensions (H x W x D)
Crated - in.
44.5 x 24.0 x 23.5
53.25 x 26.0 x 23.5
59.5 x 26.0 x 23.5
- (mm)
(1130 x 610 x 597)
(1353 x 660 x 597)
(1511 x 660 x 597)
Uncrated - in.
43.0 x 21.5 x 21.0
52.0 x 23.5 x 21.0
58.0 x 23.5 x 21.0
- (mm)
(1092 x 546 x 533)
(1321 x 597x 533)
(1473 x 597 x 533)
Weight Ibs. (kg)
Shipping
125 (56.7)
165 (74.8)
198 (898)
Net
115 (52.2)
150 (68.0)
183 (83.0)
Minimum filter size for horizontal applications based on airflow selection and calculated as follows:
Low Velocity Filter: Face Area (sq ft) = CFM/300