7
Pub. No. 22-1840-14
General
Data
TDHM PRODUCT SPECIFICATIONS
MODEL
TYPE
RATINGS
2
40% (low) heat Input BTUH
40% (low) heat Capacity BTUH (ICS)
3
100% (high) heat Input BTUH
100% (high) heat Capacity BTUH (ICS)
3
Temp. rise (Min.-Max.) °F.
AFUE
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
FLA
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT Size Min. (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
5
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
TDHMC080ACV3VB
6
Downflow / Horizontal Right
32,000
30,400
80,000
76,000
35 - 65
96.0
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
5.2 - 6.2
7
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
8.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 158
TDHMD120BCV5VB
6
Downflow / Horizontal Right
48,000
45,600
120,000
114,000
40 - 70
95.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
9.9
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
2 - 16x20 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
13.5
15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 196
TDHMC100ACV4VB
Downflow / Horizontal Right
40,000
38,400
100,000
96,000
35 - 65
96.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
3/4
Variable
115/1/60
7.4
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
2 - 16x20 - 1 in.
2.5 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
10.4
15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
185 / 175
TDHMB060BCV3VB
6
Downflow / Horizontal Right
24,000
22,800
60,000
57,000
30 - 60
95.0
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
5.2
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
7.7
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
160/ 146
1
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5
Furnace ships in natural gas configuration. The LP conversion kit used with the modulating furnace is BAYLPSS220B or BAYLPKT220B.
6
Energy Star
7
Check motor nameplate for actual FLA