background image

14

22-1674-04-0803 (EN)

Twinning
Field Wiring

TWIN

TWIN

R1

R1

TWINNING CONNECTION DIAGRAM

FOR TWINNING 1 STAGE FURNACES WITH

SINGLE WIRE TWINNING FEATURE

1 STAGE HEATING ONLY THERMOSTAT

1 STAGE HEAT

ONLY

THERMOSTAT

(WITH FAN SWITCH)

FURNACE NO. 1

FURNACE NO. 2

BLOWER OPERATION OF 

UNIT NO. 2 IS SYNCRONIZED

WITH UNIT NO. 1 VIA SIGNALS

FROM TWIN CONNECTION.

SEE NOTE 4

SEE NOTE 3

ISOLATION RELAY
(FIELD SUPPLIED)

SEE NOTE 4

ISOLATION RELAY

SEE NOTE 4

B/C

B/C

B/C

From Dwg. 21B341422 Rev. 3

TWIN

TWIN

R1

R1

TWINNING CONNECTION DIAGRAM

FOR TWINNING 1 STAGE FURNACES WITH

SINGLE WIRE TWINNING FEATURE

1 STAGE HEAT / 1 STAGE COOL THERMOSTAT

1 STAGE

HEATING / COOLING

THERMOSTAT

FURNACE NO. 1

FURNACE NO. 2

BLOWER OPERATION OF 

UNIT NO. 2 IS SYNCRONIZED

WITH UNIT NO. 1 VIA SIGNALS

FROM TWIN CONNECTION.

SEE NOTE 4

SEE NOTE 5

ISOLATION RELAY
(FIELD SUPPLIED)

SEE NOTE 4

ISOLATION RELAY

SEE NOTE 4

OUTDOOR UNIT

(NO TRANSFORMER)

OUTDOOR UNIT

(WITH TRANSFORMER)

RC

ISOLATION RELAY
(FIELD SUPPLIED)

SEE NOTE 3

B/C

B/C

B/C

From Dwg. 21B341423 Rev. 2

Summary of Contents for TDX040C924D

Page 1: ...izontal Left Downflow Horizontal Right Condensing Direct Vent Gas Fired Furnace XR 90 TUX040 060 080 100 120C TDX040 060 080 100 120C Single Stage Fan Assisted Combustion System PUB NO 22 1674 04 0803 EN TUX D 2 ...

Page 2: ...otal control of furnace limit sensors blowers gas valve flame control and includes self diagnostics for ease of service Also contains connec tion points for E A C humidifier AIR DELIVERY The four speed direct drive blower motor has sufficient airflow for most heating and cooling requirements will switch from heating to cooling speeds on demand from room thermostat The blower door safety switch wil...

Page 3: ...steel second ary heat exchanger Inner blower doors Direct drive 4 speed motors Silicon Nitride igniter with adaptive heat up Accessory hook up capability Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve regulator Cleanable high velocity filters PVC venting 1 or 2 pipe vent option Left right gas connection Selectable cooling fan off delay eliminat...

Page 4: ...igh Efficiency 17 1 2 Wide Gas Furnace TFM175A9FR0 Electronic Air Filter Perfect Fit High Efficiency 21 Wide Gas Furnace TFM210A9FR0 Electronic Air Filter Perfect Fit High Efficiency 24 1 2 Wide Gas Furnace TFM245A9FR0 Electronic Air Filter Perfect Fit Standard Efficiency 17 1 2 Wide Gas Furnace TFP175A9FR0 Electronic Air Filter Perfect Fit Standard Efficiency 21 Wide Gas Furnace TFP210A9FR0 Elect...

Page 5: ... 000 74 000 92 0 30 60 DIRECT 10 x 11 1 4 See Fan Performance Table 3 4 1075 115 1 60 Centrifugal Direct 1 1 25 3200 115 1 60 1 35 Yes High Velocity 1 20x25 1in 2 Round Aluminized Steel Type I 20 4 45 4 56 Redundant Single Stage Hot Surface Ignition Multiport Inshot 4 115 1 60 13 5 20 1 2 H x W x D 41 3 4 x 23 x 30 1 2 171 160 TUX040C924D Upflow Horizontal 40 000 38 000 92 0 30 60 DIRECT 9 x 7 1 4...

Page 6: ...dard tests 4 The above wiring specifications are in accordance with National Electrical Code however installations must comply with local codes TUX100C948D Upflow Horizontal 100 000 93 000 92 0 35 65 DIRECT 10 x 10 1 4 See Fan Performance Table 1 2 1075 115 1 60 Centrifugal Direct 1 1 20 3450 115 1 60 0 71 Yes High Velocity 1 20x25 1in 2 Round Aluminized Steel Type I 20 5 45 5 56 Redundant Single ...

Page 7: ...dard tests 4 The above wiring specifications are in accordance with National Electrical Code however installations must comply with local codes TDX040C924D Downflow Horizontal 40 000 38 000 91 0 30 60 DIRECT 10 x 7 1 4 See Fan Performance Table 1 5 1080 115 1 60 Centrifugal Direct 1 1 55 3000 115 1 60 1 14 Yes High Velocity 2 14x20 1in 2 Round Aluminized Steel Type I 20 2 45 2 56 Redundant Single ...

Page 8: ... level For Canadian applicaitons above input ratings BTUH are up to 4 500 feet derate 4 per 1 000 feet for elevations above 4 500 feet above sea level 3 Based on U S government standard tests 4 The above wiring specifications are in accordance with National Electrical Code however installations must comply with local codes TDX120C960D Downflow Horizontal 120 000 110 000 91 0 40 70 DIRECT 11 x 10 1...

Page 9: ...1 1267 1811 1687 1460 1229 TUX100C948D 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 2054 1932 1762 1558 1980 1875 1720 1546 1906 1818 1677 1533 1826 1746 1615 1477 1746 1673 1552 1421 1649 1577 1463 1350 1551 1481 1373 1278 1428 1371 1266 1175 1305 1260 1158 1071 TUX100C960D 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 2411 2108 1772 1480 2358 2083 1759 1477 2304 2058 1745 14...

Page 10: ...1 1095 1254 1202 1126 1032 1180 1137 1056 960 1101 1069 979 879 1016 998 896 790 TDX100C948D 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 1892 1779 1630 1444 1827 1726 1587 1416 1762 1672 1544 1388 1688 1605 1485 1348 1614 1538 1426 1308 1531 1460 1362 1246 1448 1381 1297 1184 1354 1291 1208 1108 1260 1200 1119 1032 TDX120C960D 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 221...

Page 11: ...22 1674 04 0803 EN 11 Electrical Data From Dwg D341852 Rev 1 ...

Page 12: ...12 22 1674 04 0803 EN Electrical Data From Dwg D341854 Rev 1 ...

Page 13: ...IELD WIRING DIAGRAM FOR 1 STAGE FURNACE 1 STAGE HEATING 1 STAGE COOLING USING A 1 STAGE HEATING 1 STAGE COOLING THERMOSTAT OUTDOOR SECTION WITHOUT TRANSFORMER SEE NOTE 6 From Dwg B341437 Rev 1 FURNACE TWIN SEE NOTE 7 B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE 1 STAGE HEATING USING A 1 STAGE HEATING THERMOSTAT NO C...

Page 14: ...EE NOTE 4 ISOLATION RELAY SEE NOTE 4 B C B C B C From Dwg 21B341422 Rev 3 TWIN TWIN R1 R1 TWINNING CONNECTION DIAGRAM FOR TWINNING 1 STAGE FURNACES WITH SINGLE WIRE TWINNING FEATURE 1 STAGE HEAT 1 STAGE COOL THERMOSTAT 1 STAGE HEATING COOLING THERMOSTAT FURNACE NO 1 FURNACE NO 2 BLOWER OPERATION OF UNIT NO 2 IS SYNCRONIZED WITH UNIT NO 1 VIA SIGNALS FROM TWIN CONNECTION SEE NOTE 4 SEE NOTE 5 ISOLA...

Page 15: ...2 TUX C D Outline Drawing ALL DIMENSIONS ARE IN INCHES Dimensions MODEL A B C D E F TUX040C924 TUX060C936 TUX080C942 17 1 2 2 1 4 16 1 4 16 7 1 2 2 TUX080C960 TUX100C948 21 2 1 2 19 3 4 19 1 2 9 3 TUX100C960 TUX120C960 24 1 2 2 15 16 23 1 4 23 10 3 ...

Page 16: ...ign and specifications without notice Trane A business of American Standard Companies www trane com From Dwg 21C341885 Rev 0 TDX C D Outline Drawing ALL DIMENSIONS ARE IN INCHES Dimensions Literature Order Number TUX D 2 File Number PL UN FURN TUX D 2 08 03 Supersedes TUX D 1 06 02 Stocking Location PI Louisville ...

Reviews: