background image

10

22-1706-01-0400 (EN)

Field
Wiring

From Dwg. 21B341333 Rev. 0

From Dwg. 21B341332 Rev. 0

FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING

Summary of Contents for TDX060R936V

Page 1: ...Downflow Horizontal Two stage Condensing Gas Fired Furnace XL 90 TDX060 080 100 120R V Direct Vent with Variable Speed Inducer PUB NO 22 1706 01 0400 EN ...

Page 2: ... for E A C humidifier Condensate Drain Built in trap which can drain from either side when the furnace is installed upflow Air Delivery The variable speed direct drive blower motor has sufficient airflow for most heating and cooling requirements will switch from heating to cooling speeds on demand from room thermostat The blower door safety switch will prevent or terminate furnace operation when t...

Page 3: ...ents Feature Summary 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6 TDX060R936V 6 TDX080R942V 6 TDX100R948V 6 TDX120R960V 6 Performance Data 7 Electrical Data 9 Field Wiring 10 Dimensions 14 ...

Page 4: ...ners Alternate bottom left right return air in vertical position Slide out blower assembly Direct drive 4 speed motors Adjustable fan off times Single pipe venting Cleanable high velocity filters Heavy gauge reinforced wrap around steel cabinet Super quiet performance Complete front service access Optional L P conversion kit Left right gas connection Limited lifetime warranty on primary and second...

Page 5: ... 1 2 Wide Gas Furnace TFE245A9FR0 Electronic Air Filter Perfect Fit High Efficiency 17 1 2 Wide Gas Furnace TFM175A9FR0 Electronic Air Filter Perfect Fit High Efficiency 21 Wide Gas Furnace TFM210A9FR0 Electronic Air Filter Perfect Fit High Efficiency 24 1 2 Wide Gas Furnace TFM245A9FR0 Electronic Air Filter Perfect Fit Standard Efficiency 17 1 2 Wide Gas Furnace TFP175A9FR0 Electronic Air Filter ...

Page 6: ...1 3 1075 115 1 60 CENTRIFUGAL DIRECT VARIABLE 1 15 5000 115 1 60 1 1 YES HIGH VELOCITY 2 14 X 20 X 1 2 ROUND ALUMINIZED STEEL TYPE 1 20 3 45 3 56 REDUNDANT TWO STAGE HOT SURFACE IGNITER IN SHOT 4 115 1 60 9 1 15 0 50 SEE OUTLINE DRAWING H X W X D 41 3 4 X 19 1 2 X 30 1 2 SEE OUTLINE DRAWING 155 145 TDX080R942V 52000 48000 80000 74000 92 5 35 65 DIRECT 11 x 8 1 4 SEE FAN PERF TABLE 1 2 1075 115 1 6...

Page 7: ... 1487 1388 1263 1498 1436 1348 1234 1445 1382 1302 1196 1386 1325 1249 1150 1323 1265 1191 1095 1254 1202 1126 1032 1180 1137 1056 960 1101 1069 979 879 1016 998 896 790 TDX100R948V 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 1892 1779 1630 1444 1827 1726 1587 1416 1762 1672 1544 1388 1688 1605 1485 1348 1614 1538 1426 1308 1531 1460 1362 1246 1448 1381 1297 1184 1354 1291 1208 1108 12...

Page 8: ... TDX120R960V Not Allowed Not Allowed 50 NOTES 1 Minimum vent length for all models 3 horizontal and vertical 2 DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET Except adapters at the top of the furnace 3 MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED THE LENGTH SHOWN IS NOT A COMBINED TOTAL IT IS THE MAXIMUM LENGTH OF EACH Vent or Inlet air pipes 4 One SHORT radius 90 el...

Page 9: ...22 1706 01 0400 EN 9 Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES LEGEND From Dwg 21D341250 P02 TDX060 080 100 120R V ...

Page 10: ...10 22 1706 01 0400 EN Field Wiring From Dwg 21B341333 Rev 0 From Dwg 21B341332 Rev 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ...

Page 11: ...From Dwg 21B341335 Rev 0 From Dwg 21B341334 Rev 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING OUTDOOR SECTION WITHOUT TRANSFORMER FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING COOLING OUTDOOR SECTION WITHOUT TRANSFORMER ...

Page 12: ...g From Dwg 21B341337 Rev 0 Twinning Connection Diagram ForTwinning UX DX R Furnaces 2 Stage Heat 2 Stage CoolingThermostat From Dwg 21B341338 Rev 0 Twinning Connection Diagram ForTwinning UX DX R Furnaces 2 Stage Heat 1 Stage CoolingThermostat ...

Page 13: ...22 1706 01 0400 EN 13 Twinning Connection Diagram ForTwinning UX DX R Furnaces 1 Stage Heat 1 Stage CoolingThermostat From Dwg 21B341336 Rev 0 Twinning Field Wiring ...

Page 14: ...40762 Rev 3 Notes 1 TDX100R960V requires 2 1 2 or 3 and TDX120R960V requires a 3 diameter vent pipe 2 Clearance required at top of plenum is 1 MODEL A B C D E F TDX060R936V TDX080R942V 17 1 2 2 1 4 16 1 4 16 7 1 2 2 TDX100R948V 21 2 1 2 19 3 4 19 1 2 9 3 TDX120R960V 24 1 2 2 15 16 23 1 4 23 10 3 ...

Page 15: ...22 1706 01 0400 EN 15 Notes ...

Page 16: ...00 Troup Highway Tyler TX 75707 9010 www trane com An American Standard Company P I Since The Trane Company has a policy of continuous product and product data improvement it reserves the right to change design and specifications without notice ...

Reviews: