background image

7

PUB. NO. 22-1802-03

General
Data

Product Specifications 

1

MODEL
TYPE
RATINGS   

2

1st Stage Input BTUH

1st Stage Capacity BTUH (ICS) 

 

3

2nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS)  

3

Temp. rise (Min.-Max.) °F.

BLOWER DRIVE

Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz

COMBUSTION FAN — Type

Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA

FILTER — Furnished?

Type
Max. Indoor Relative Humidity 

5

VENT — Size (In.)
HEAT EXCHANGER

Type-Fired

-Unfired

Gauge (Fired)

ORIFICES — Main

Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size

GAS VALVE
PILOT SAFETY DEVICE

Type

BURNERS — Type

Number

POWER CONN. — V / Ph / Hz  

4

Ampacity (In Amps)
Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (In.)
DIMENSIONS

Crated (In.)
Uncrated (In.)

WEIGHT

Shipping (Lbs.) / Net (Lbs.)

*UD2D120AFV52A

Upflow / Horizontal

78,000
62,400

120,000

97,000

35 - 65

Direct

10 x 10

1

Variable

See Airflow Table

1

Variable

115/1/60

Centrifugal

Direct - 2

1/60 - 3090/2225

115/1/60

1.14/0.51

Yes

Whole House Air Cleaner

65%

4 Round

Alum. Steel - Type 1

20

6 — 45
6 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot

6

115/1/60

15.3

20

1/2

H x W x D

41-3/4 x 26-1/2 x 30-1/2

40 x 24-1/2 x 28-1/2

193 / 181

*UD2B100AFV32A

Upflow / Horizontal

65,000
52,000

100,000

80,000

40 - 70

Direct

10 x 7

1

Variable

See Airflow Table

1/2

Variable

115/1/60

Centrifugal

Direct - 2

1/75 - 2708/1868

115/1/60

0.87/0.49

Yes

Whole House Air Cleaner

65%

4 Round

Alum. Steel - Type 1

20

5 — 45
5 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot

5

115/1/60

10.8

15

1/2

H x W x D

41-3/4 x 19-1/2 x 30-1/2

40 x 17-1/2 x 28-1/2

142 / 132

1

Central Furnace heating designs are certified by AGA and CSA.

2

For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input
ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3

Based on U.S. government standard tests.

4

The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

5

The FIELD CHARGER may require more frequent cleaning in homes with high indoor relative humidity (greater than 65% RH).  Consult your service professional about cleaning
intervals.

Summary of Contents for TUD2B060AFV32A

Page 1: ...izontal 80 2 Stage Variable Speed Gas Fired Furnace with Whole House Air Cleaner PUB NO 22 1802 03 XV80i TUD2B060AFV32A TUD2B080AFV32A TUD2C080AFV42A TUD2B100AFV32A TUD2D120AFV52A 2009 Trane All Right...

Page 2: ...can be converted to L P gas INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors blowers gas valve flame control and includes self diagnos...

Page 3: ...pment Optional Equipment General Data TUD2B060AFV32A TUD2B080AFV32A TUD2C080AFV42A TUD2B100AFV42A TUD2D120AFV52A Performance Data Electric Data Field Wiring Diagrams Dimensions Contents 2 2 2 2 2 4 4...

Page 4: ...gauge aluminized steel heat exchanger Multi port In shot burners Complete front service access Alternate bottom left right return air Slide out blower assembly Hingedblowerdoor Perfect fit door catch...

Page 5: ...mostat Electronic Programmable 5 2 1 Stage Heating 1 Stage Cooling BAYSTAT340 Thermostat Heating Cooling Single Stage Mounts Vertically BAYSTAT305 Thermostat Electronic Programmable 2 Stage Heating 2...

Page 6: ...Variable SeeAirflow Table 1 2 Variable 115 1 60 Centrifugal Direct 2 1 100 2543 1727 115 1 60 0 70 0 40 Yes Whole House Air Cleaner 65 4Round Alum Steel Type 1 20 4 45 4 56 Redundant Two Stage Hot Su...

Page 7: ...Ignition Multi port In shot 6 115 1 60 15 3 20 1 2 H x W x D 41 3 4 x 26 1 2 x 30 1 2 40 x 24 1 2 x 28 1 2 193 181 UD2B100AFV32A Upflow Horizontal 65 000 52 000 100 000 80 000 40 70 Direct 10 x 7 1 V...

Page 8: ...137 198 259 316 361 CFM 831 883 915 935 941 Watts 122 182 238 292 345 CFM 1023 1052 1055 1061 1048 Watts 203 266 316 370 413 CFM 1156 1174 1188 1196 1085 Watts 280 351 415 482 442 CFM 1063 1094 1090...

Page 9: ...22 1111 1101 1083 Watts 269 317 361 405 442 CFM 1310 1295 1273 1246 1136 Watts 405 457 498 535 490 CFM 1458 1420 1369 1266 1154 Watts 569 599 606 561 506 CFM 1329 1310 1287 1253 1142 Watts 424 472 516...

Page 10: ...1334 1296 Watts 252 326 394 456 502 CFM 1167 1193 1208 1196 1193 Watts 190 255 321 378 443 CFM 1356 1378 1383 1358 1321 Watts 279 355 424 473 518 CFM 1521 1528 1537 1537 1344 Watts 379 545 534 606 55...

Page 11: ...atts 146 206 260 309 343 CFM 848 907 934 946 946 Watts 133 188 245 289 334 CFM 1018 1044 1055 1065 983 Watts 206 262 319 370 357 CFM 1139 1160 1184 1122 1020 Watts 274 344 411 417 386 CFM 1071 1089 11...

Page 12: ...563 640 605 CFM 1334 1376 1424 1411 1417 Watts 251 330 415 469 562 CFM 1582 1628 1659 1663 1465 Watts 387 491 595 672 595 CFM 1813 1836 1838 1707 1504 Watts 577 684 771 710 620 CFM 1704 1731 1733 1735...

Page 13: ...PUB NO 22 1802 03 WIRING DIAG WIRING DIAG WIRING DIAG WIRING DIAG WIRING DIAGRAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES Electrical Da...

Page 14: ...22 1802 03 SCHEMA SCHEMA SCHEMA SCHEMA SCHEMATIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES Elect...

Page 15: ...s only for thermostats requiring connection to transformer common terminal 11 Optional humidistat is to be connected between R and BK Factory installed jumper R to BK on the circuit board must be cut...

Page 16: ...delays 9 Optional humidistat is to be connected between R and BK Factory installed jumper R to BK on the circuit board must be cut if optional humidistat is used The jumper must also be cut when apply...

Page 17: ...ER SEE NOTE 9 FIELD ADDED JUMPER W1 TO W2 2ND STAGE WILL FIRE 10 MINUTES AFTER 1ST B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STA...

Page 18: ...NOTE 9 W14 JUMPER SEE NOTE 9 From Dwg B342020 Rev 0 B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE 2 STAGE HEATING 1 ST...

Page 19: ...TRANSFORMER SEE NOTE 3 SEE NOTE 6 SEE NOTE 7 From Dwg B342018 Rev 0 B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE 2 S...

Page 20: ...IN INCHES MODEL DIM A DIM B DIM C DIM D DIM E UD2B060AFV32A UD2B080AFV32A UD2B100AFV32A 17 1 2 9 5 8 16 1 4 16 16 UD2C080AFV42A 21 13 1 16 19 3 4 19 1 2 19 1 2 UD2D120AFV52A 24 1 2 15 5 16 23 1 4 23...

Page 21: ...NOTES...

Page 22: ...Since Trane has a policy of continuous product improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 www trane com...

Reviews: