PRODUCT  TYPE
TC = Package Cooling
WC = Package Heat Pumps

AIRFLOW CONFIGURATION
C = Convertible

NOMINAL NET COOLING
CAPACITY
030 = 30 MBh
040 = 40 MBh
050 = 50 MBh

MAJOR DESIGN MODIFICATION
F = Impack

ELECTRICAL CHARACTERISTICS
D = 380-415V/3/50

PRODUCT
SERVICE CHANGE

MINOR DESIGN
MODIFICATION

FACTORY INSTALLED OPTIONS
EXAMPLES:
0 = No factory installed options

AUXILIARY HEATING CAPACITY
Ø = No Auxiliary Heat (from Factory)

Model Number Nomenclature

Selection
Procedure

Summary of Contents for WCC030

Page 1: ...50 Hz Package Heat Pump Units Product Data Convertible Models WCC030 040 050 30 40 50 MBh IPB 99 7 EN 10 6 99 ...

Page 2: ... 99 7 EN 10 6 99 General Features T Top Corrosion Resistant Screws Powder Paint Water Shed Base High Efficiency Climatuff Compressor DuraTuff Plate Fin Coil Time Defrost Control Sloped Drain Pan 100 Foil Faced Insulation Easy Access ...

Page 3: ...ature 7 General Data 8 English Units WCC030FD00B 8 WCC040FD00B 8 WCC050FD00B 8 Metric Units WCC030FD00B 9 WCC040FD00B 9 WCC050FD00B 9 Performance Data 10 Cooling English Units 10 Cooling Metric Units 11 Heating English Units 12 Heating Metric Units 13 Indoor Blower Performance 14 Optional Equipment 15 Controls 16 FieldWiring 17 Dimensions 20 Mechanical Specification Options 26 ...

Page 4: ...ll tonnage is not needed The other kit maintains head pressure and full capacity at zero degrees Quality and Reliability Testing We perform a 100 coil leak test at the factory The evaporator and condenser coils are leak tested at the factory The evaporator and condenser coils are leak tested at 200 psig and pressure tested to 450 psig respectively In addition the Impack designs were rigorously rai...

Page 5: ... reducing the number of circuit pulls needed Standard Thermostats No special thermostats are needed with Impack units Filter Frame Kit The Impack filter frames accept standard filters and fit inside the unit The frame kits function in either horizontal or downflow duct configurations Coil Guard Kit The guards are vinyl coated 1 x 3 wire grills These grills will protect the coil from hail kids with...

Page 6: ... BAYDUCT004A 14 Round Duct Adapter 1 per box WCC040 050F BAYDUCT005A 0 100 Mod Economizer w Baro Relief WCC030F 12345 BAYECON054A 0 100 Mod Economizer w Baro Relief WCC040 050F 12345 BAYECON055A 0 100 Horizontal Economizer 23 BAYECON073A Enthalpy Control solid state WCC F 3 BAYENTH001A Economizer Relay Kit WCC F 1 BAYRLAY003A Filter Frame 20x25x1 filter not incl WCC030F 2 BAYFLTR012A Filter Frame ...

Page 7: ...e NOMINAL NET COOLING CAPACITY 030 30 MBh 040 40 MBh 050 50 MBh MAJOR DESIGN MODIFICATION F Impack ELECTRICAL CHARACTERISTICS D 380 415V 3 50 PRODUCT SERVICE CHANGE MINOR DESIGN MODIFICATION FACTORY INSTALLED OPTIONS EXAMPLES 0 No factory installed options AUXILIARY HEATING CAPACITY Ø No Auxiliary Heat from Factory Model Number Nomenclature Selection Procedure ...

Page 8: ...CT 1 2040 1 1 2 900 380 415 1 50 1 7 3 8 CENTRIFUGAL 10 X 9 1 DIRECT 2 SEE FAN PERFORMANCE TABLE 1 1 3 900 380 415 1 50 1 1 2 6 NO THROWAWAY 3 10 x 25 8 2 LBS H X W X D 35 1 4 X 38 X 57 SEE OUTLINE DRAWING 406 366 WCC040FD00B 380 415 3 50 39600 1325 4 10 9 70 10 95 8 4 39400 3 18 3 66 20700 2 06 2 96 6 80 380 415 3 50 13 8 20 20 CLIMATUFF 1 380 415 3 50 8 0 51 7 1 PLATE FIN 2 15 14 0 3 8 TXV BLEED...

Page 9: ...LLER 1 457 DIRECT 1 3448 1 1 2 900 380 415 1 50 1 7 3 8 CENTRIFUGAL 254 X 229 1 DIRECT 2 SEE FAN PERFORMANCE TABLE 1 1 3 900 380 415 1 50 1 1 2 6 NO THROWAWAY 3 254 x 635 3 72 KG H X W X D 895 X 965 X 1448 SEE OUTLINE DRAWING 184 166 WCC040FD00B 380 415 3 50 11606 2240 4 10 9 70 10 00 10 95 8 4 11547 3 18 3 66 6067 2 06 2 96 6 80 380 415 3 50 13 8 20 20 CLIMATUFF 1 380 415 3 50 8 0 51 7 1 PLATE FI...

Page 10: ... 0 27 5 30 1 32 6 35 1 3 09 67 40 4 19 6 22 1 24 7 27 2 29 7 3 16 71 43 2 14 1 16 6 19 1 21 7 24 2 3 24 59 33 9 29 5 32 1 34 2 35 1 35 9 3 16 105 63 36 5 24 6 27 1 29 6 32 2 34 7 3 23 67 39 2 19 2 21 7 24 2 26 8 29 3 3 30 71 42 0 13 7 16 2 18 7 21 3 23 8 3 37 59 32 0 28 7 31 3 32 6 33 4 34 2 3 45 115 63 34 4 23 8 26 3 28 8 31 3 33 9 3 51 67 37 0 18 4 20 9 23 4 25 9 28 5 3 57 71 39 6 12 8 15 4 17 9...

Page 11: ...8 7 3 2 21 7 12 7 4 1 4 9 5 6 6 4 7 1 3 2 15 0 9 9 8 6 9 4 10 0 10 3 10 5 3 2 40 6 17 2 10 7 7 2 7 9 8 7 9 4 10 2 3 2 19 4 11 5 5 6 6 4 7 1 7 9 8 6 3 3 21 7 12 3 4 0 4 7 5 5 6 2 7 0 3 4 15 0 9 4 8 4 9 2 9 6 9 8 10 0 3 5 46 1 17 2 10 1 7 0 7 7 8 4 9 2 9 9 3 5 19 4 10 8 5 4 6 1 6 9 7 6 8 4 3 6 21 7 11 6 3 8 4 5 5 2 6 0 6 7 3 6 CORRECTION FACTORS OTHER AIRFLOWS MULTIPLY OR ADD AS INDICATED AIRFLOW 19...

Page 12: ...3 46 37 31 6 30 8 30 4 30 0 3 25 3 42 3 50 3 58 42 34 2 33 3 32 9 32 4 3 36 3 53 3 62 3 70 47 40 5 39 4 38 9 38 3 3 48 3 66 3 75 3 84 52 43 7 42 5 41 9 41 4 3 59 3 78 3 87 3 96 57 46 9 45 6 45 0 44 4 3 70 3 89 3 99 4 09 62 50 1 48 8 48 1 47 4 3 81 4 01 4 11 4 21 67 53 3 51 9 51 2 50 4 3 92 4 13 4 23 4 33 72 56 5 55 0 54 2 53 5 4 03 4 24 4 35 4 46 CORRECTION FACTORS OTHER AIRFLOWS VALUE AT 1325 CFM...

Page 13: ...8 9 26 9 02 8 91 8 79 3 25 3 42 3 50 3 58 5 6 10 02 9 76 9 64 9 49 3 36 3 53 3 62 3 70 8 3 11 87 11 54 11 40 11 22 3 48 3 66 3 75 3 84 11 1 12 80 12 45 12 28 12 13 3 59 3 78 3 87 3 96 13 9 13 74 13 36 13 18 13 01 3 70 3 89 3 99 4 09 16 7 14 68 14 30 14 09 13 89 3 81 4 01 4 11 4 21 19 4 15 62 15 21 15 00 14 77 3 92 4 13 4 23 4 33 22 2 16 55 16 11 15 88 15 68 4 03 4 24 4 35 4 46 CORRECTION FACTORS O...

Page 14: ... 1420 2400 0 56 140 488 0 40 0 28 70 448 0 28 1460 2467 0 53 132 498 0 41 0 19 47 463 0 26 1500 2535 0 50 125 508 0 42 0 10 25 479 0 24 1540 2602 0 47 117 518 0 43 0 01 2 5 495 0 23 1580 2670 0 44 110 528 0 44 1630 2755 0 41 102 537 0 45 1670 2825 0 38 95 547 0 46 1710 2890 0 35 87 557 0 47 1750 2958 2 0 31 77 567 0 48 1 Factory setting at LO speed 2 Water Blow Off Unit 3 Wet coil no filter no hea...

Page 15: ...IPB 99 7 EN 10 6 99 15 Optional Equipment 25 Manual Fresh Air Kit Typical Filter Frame ...

Page 16: ...rd equipment offering is a fixed dry bulb changeover control In addition to the standard offering there are two other field installed control accessories Enthalpy Control Replaces the dry bulb control with a solid state dry bulb and wet bulb changeover controller which has a fully adjustable set point Enthalpy control offers a higher level of energy savings potential than the standard dry bulb con...

Page 17: ...ECTION OF THE OUTDOOR THERMOSTAT ACCESSORY ONLY FOR FURTHER UNIT CONNECTION DETAILS REFER TO THE OTHER FIGURES 8 THE 41A BR WIRE IS FIRST STAGE ELECTRIC HEAT IF THE ELECTRIC HEATER ACCESSORY HAS TWO HEATING STAGES THE 41C BR WIRE IS SECOND STAGE ELECTRIC HEAT 9 WHEN THE BAYECON054A OR 055A ECONOMIZER IS INSTALLED THE BAYRLAY003 RELAY ACCESSORY KIT IS REQUIRED TO INTERFACE THE ECONOMIZER TO THE HEA...

Page 18: ...18 IPB 99 7 EN 10 6 99 Field Wiring Wiring Diagram for WCC030 040 050FD00B Units From Dwg 21D756914 P03 continued on next page ...

Page 19: ...IPB 99 7 EN 10 6 99 19 Field Wiring Wiring Diagram for WCC030 040 050FD00B Units From Dwg 21D756914 P03 ...

Page 20: ...350 11 4 32 83 4 222 13 16 2 1 14 355 8 200 A B D C RETURN SUPPLY MODEL NO AIR DUCT OPENINGS A B C D WCC030F SUPPLY 21 533 16 3 4 425 RETURN 21 533 21 1 8 540 WCC040F WCC050F SUPPLY 21 533 19 483 RETURN 21 533 22 1 8 565 All dimensions are in inches mm From Dwg 21C662039 From Dwg 21C729942 INSULATED DECK PANS ARE INCLUDED WITH THE BAYCURB038A ONLY SERVICE CLEARANCE PENETRATION DIMENSIONS MODEL NO ...

Page 21: ...INCHES MM Required Clearance for Unit Installation and Roof Penetration Hole Size Required ALL DIMENSIONS ARE IN INCHES MM MODEL NO AIR DUCT OPENINGS A B C WCC040F WCC050F SUPPLY 21 533 19 482 RETURN 21 533 22 1 8 565 All dimensions are in inches mm From Dwg 21C662039 From Dwg 21C662034 SERVICE CLEARANCE DIMENSIONS MODEL NO A B C D WCC040F WCC050F 42 1070 30 815 6 150 36 915 18 457 WITH 25 FRESH A...

Page 22: ...M NOTES 1 OVERLAP AND POSITION JOINTS IN P V C RUBBER GASKET 2 AIR SEALS APPLY P V C RUBBER LAST TO INSURE THERE IS ADEQUATE P V C FOR THE WATER SEAL 3 USE TYPICAL SEALING METHODS TO PREVENT AIR DUCT LEAKAGE AT CURB DUCT JOINT Field Fabricated Side X Side Ducts WCC030 050F Units Installed from Above Mounting Curb ALL DIMENSIONS ARE IN INCHES MM ...

Page 23: ... 21D661772 CABINET SIZE MODEL BAYCURB A B C D E F G H B WCC030F 030A 14 1 8 360 16 5 8 425 36 915 34 865 29 3 16 740 13 3 4 350 D WCC040F WCC050F 030A 14 13 16 380 21 535 45 1145 34 865 33 3 8 850 13 3 4 350 10 1 8 261 9 7 8 251 D WCC040F WCC050F 034A 14 13 16 380 21 533 45 1145 43 1092 33 3 8 850 13 3 4 350 ...

Page 24: ...ONS ARE IN INCHES MM From Dwg 21D729945 Rev 5 MODEL A B C D E F WCC030F 55 1 4 1405 36 915 29 3 16 740 12 15 16 330 4 7 8 122 KNOCKOUTS FOR 3 4 20 AND 1 1 4 32 CONDUIT WCC040F WCC050F 64 5 16 1634 45 1145 33 3 8 850 14 13 16 375 4 7 8 122 KNOCKOUTS FOR 3 4 20 AND 1 1 2 38 CONDUIT ...

Page 25: ... B C D E F G H J K L M N P W1 W2 W3 W4 WCC030F 94 43 73 33 80 36 104 47 318 144 55 1 4 1400 36 915 29 3 16 750 18 9 16 470 11 1 16 280 6 9 16 170 6 13 16 170 17 430 18 13 16 465 24 610 17 1 2 445 10 250 3 75 4 7 16 115 WCC040F 126 57 104 47 127 58 153 70 486 220 64 5 16 1634 45 1145 33 3 8 846 21 1 16 535 15 1 16 385 4 15 16 120 9 1 8 230 21 15 16 550 24 3 4 628 29 736 20 500 14 350 3 1 2 90 8 5 1...

Page 26: ...eral The units shall be horizontal airflow as shipped and convertible to downflow All units shall be factory assembled piped internally wired and fully charged with R 22 Units shall be UL listed and carry a UL label All units shall be factory run tested to check cooling operation fan and blower rotation and control sequence Units shall be designed to operate at ambient temperatures between 115 F a...