1.

 

VERIFY PROPER OPERATION OF CAMERA CONTROL USING A DIRECT WIRED
CONNECTION PRIOR TO INSTALLING WIRELESS LINK.

2.

 

SET THE PTZ-900TX AND PTZ-900RX SERIAL PORT DATA RATE AND MODE (RS422 or
RS232) USING THE TRANGOLINK PROGRAM AND SUPPLIED CABLE.  (THIS STEP
 NOT
REQUIRED IF THE PTZ CONTROL EQUIPMENT IS SET TO USE 9600 BPS and RS422 or
RS485 MODE
)

3.

 

INSTALL TRANSMITTER AND RECEIVER UNITS  IN DESIRED LOCATION TO 2 3/8”
MAX DIAMETER STEEL POLE PER INSTALLATION DRAWING.

4.

 

INSTALL ANTENNAS ABOVE THE ENCLOSURES AND ALIGN PROPERLY.

IMPORTANT NOTE:  THE PTZ-900TX (TRANSMITTER) USES A SPECIAL ANTENNA
CONNECTOR.  ONLY USE ANTENNAS SUPPLIED BY TRANGO SYSTEMS WITH THIS TYPE
OF CONNECTOR OR DAMAGE TO THE UNIT MAY OCCUR.

5.

 

TIGHTEN ANTENNA CABLE TO RECEIVER AND TRANSMITTER.  APPLY A SMALL
AMOUNT OF SILICONE TO FLANGE TO MAKE A LEAKPROOF CONNECTION.

6.

 

CONNECT INTERFACE AND POWER CABLES TO UNITS THROUGH FLANGES.
TIGHTEN FLANGES TO ALLOW SMALL AIR GAP AT BOTTOM OF ENCLOSURE.
MAKE SURE THAT GROUNDING STRAP IS SECURE TO AN EARTH GROUND.

7.

 

VERIFY THAT LEDs ARE SOLID RED ON TRANSMITTER AND RECEIVER BEFORE
SENDING PTZ COMMANDS.

8.

 

TIGHTEN LID OF ENCLOSURE DOWN.

IMPORTANT NOTE:  DO NOT APPLY POWER TO THE TRANSMITTER UNLESS THE
ANTENNA IS CONNECTED. PERMANENT DAMAGE MAY RESULT.

SAFETY NOTE:  THE PTZ-900TX TRANSMITTER OUTPUT POWER VARYS BETWEEN ½
and 4 WATTS EIRP.  ALTHOUGH TRANSMISSIONS ARE OF A SHORT DURATION, IT IS
RECOMMENDED THAT THE TRANSMIT ANTENNA BE KEPT AT LEAST 3 FEET AWAY
FROM NEARBY PERSONS.

Summary of Contents for PTZ-900

Page 1: ...______________________________________________________________________________________ 900 MHz Spread Spectrum Digital Wireless Pan Tilt Zoom Camera Control Transmission System Installation and Operating Instructions ...

Page 2: ...ons However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to correct the interference by one of more of the following meaures 1 Reorient the receiving antenna 2 Increase the separation between the...

Page 3: ...RANGO SYSTEMS WITH THIS TYPE OF CONNECTOR OR DAMAGE TO THE UNIT MAY OCCUR 5 TIGHTEN ANTENNA CABLE TO RECEIVER AND TRANSMITTER APPLY A SMALL AMOUNT OF SILICONE TO FLANGE TO MAKE A LEAKPROOF CONNECTION 6 CONNECT INTERFACE AND POWER CABLES TO UNITS THROUGH FLANGES TIGHTEN FLANGES TO ALLOW SMALL AIR GAP AT BOTTOM OF ENCLOSURE MAKE SURE THAT GROUNDING STRAP IS SECURE TO AN EARTH GROUND 7 VERIFY THAT LE...

Page 4: ...speed or use RS 232 protocol you must reprogram the PTZ 900TX and PTZ 900RX using the supplied cable and the Trangolink software which runs on any Windows 95 or higher computer See Changing System parameters section for detailed information To obtain the best performance and transmission distance the following rules of thumb should be followed 1 Mount the transmitter and receiver antennas above hu...

Page 5: ...Page 3 Fig 1 Fig 2 ...

Page 6: ... three functional modes as follows 1 Alternating Green Red The unit is waiting for a command from Trangolink 30 seconds after startup only 2 Red Unit is ready to receive data from the PTZ control equipment 3 Green The unit is sending data on the air Since the data is typically sent out in bursts the LED will be green for a very short time only RECEIVER OPERATION Figure 4 shows the front panel of t...

Page 7: ...dividual pins on the Transmitter and receiver Diagrams POINT TO MULTIPOINT OPERATION In some cases it may be necessary to control more than one camera from the same control panel In this case one PTZ 900TX transmitter would send control signals to all receivers and the receiver drivers will filter the data as in a hardwired system The user must ensure that all receivers have the same address and P...

Page 8: ...utipoint operation this is where more than one transmitter is operating in the same area In this case all the transmitters and receivers operating on System A would have the same PN code and address Those on system B should have a different address ...

Page 9: ...as industrial roof mounted air conditioners or fan motors in close proximity to the transmitter or receiver or cables may cause interference especially when operating using RS232 mode Move the unit cable away from the source of the interference Antenna polarization may be wrong The AD900 9 antenna is normally horizontally polarized which has been determined to give the best results When using Yagi...

Page 10: ...0 feet for RS422 and 200 feet for RS232 NO DATA IS RECEIVED Check that the transmit and receive PN sequences data rate mode and address are set the same Verify all connectors are tight Verify that transmitter and receiver antennas are aligned properly as discussed above CAN T COMMUNICATE WITH TRANSMITTER OR RECEIVER USING TRANGOLINK Plug in the supplied cable to the unit Power the computer on Powe...