background image

Rev. 10/07

 

 

FH320/325

User Selectable 
Temperature Ranges

FH320: 

0 to +50˚F/C, 0 to +100˚F, -10 to +40˚C 

FH325:

 0 to +100˚F, 0 to 

+50˚F/C, -25 to +125˚F, -40 to +60˚F/C, -20 to +80˚F/C, 50 to +100˚F, -40 
to +160˚F

Temperature Range

FH320

: 0 to +122˚F (-17.8 to +50˚C)

Remote Temperature 
Range

FH325

: -40 to +185˚F (-40 to +85˚C) 0 TO 95% RH

Temperature Accuracy

±0.8˚F (±0.44˚C) from +20 to +120˚F; ±1.8˚F (±1˚C) remaining

Temperature Sensor

Digital Temperature Humidity Sensor

Humidity Range

0 to 95% RH

Humidity Accuracy

±2% from 0 to 60%, ±3% from 60 to 95%

Humidity Sensor

Digital Temperature Humidity Sensor

Sample Storage Rate

Time graph interval options: 10 sec; 20 sec, 30 sec, 40 sec, 1 min, 2 min, 3 
min (user selectable)

Time Samples 
Displayed

Sample Rate/Time: 10 sec/45.8 min; 20 sec/1.5 hrs; 30 sec/2.3 hrs; 40 
sec/3 hrs, 1 min/4.5hrs; 2 min/9.1 hrs; 3 min/13.7 hrs

Download Type

USB (1:15 minutes) or FLASH Memory Card (36 seconds)

Alarm Type

Audio/visual; High/low and low battery conditions

Ambient Operating 
Conditions

Logger: 0 to +120˚F (-17.8 to +48.9˚C), 0 to 95% RH (non-condensing, 
dependent upon display operating range); Probe: -40 to +185˚F (-40 to 
+85˚C), 0 to 95% RH (non-condensing)

Data Capacity

64,000 (32,000 per channel) 275 Sample Points Displayed on Graph

Power Source

120 VAC / 60 Hz / 16 W adapter (9V battery backup)

Battery Life (Avg)

48 hours (when on battery power display goes to sleep after 1 minute - can 
be reactivated with the push of any button)

Software Required

None Required, A016 or A026 optional (v 11.7.0)

IP Rating

IP20

A

pp

lic

at

io

ns 

& P
ro

d

uc

Sp

ec

ifi

ca

tio

ns

Pr

od

uc

t

Sp

ec

ifi

ca

tio

ns

O

pe

ra

tin

In

st

ru

ct

io

ns / 

G

et

tin

g S
ta

rt

ed

O

pe

ra

tin

In

st

ru

ct

io

ns / 

G

et

tin

g S
ta

rt

ed

A

cc

es

so

rie

s, 

Tr

ou

ble

sh

oo

tin

& C
ali

br

at

io

n

A

cc

es

so

rie

s, 

Tr

ou

ble

sh

oo

tin

& C
ali

br

at

io

n

W

ar

ra

nt

y/ 

Fa

ct

or

y S
er

vic

& R
et

ur

ns

D

IC

K

SO

N

Summary of Contents for Dickson FH320

Page 1: ...ing Warranty Factory Service Returns FH325 Remote Probe Temperature Humidity FT320 Remote Probe 2 Channel Temperature Applications Product Specifications Product Specifications Operating Instructions...

Page 2: ...r Thermistor Remote Sensor FT325 Thermistor with coated tip practical for immersion 10 ft long Sample Storage Rate user selectable Time graph interval options 10 sec 20 sec 30 sec 40 sec 1 min 2 min 3...

Page 3: ...3 hrs 1 min 4 5hrs 2 min 9 1 hrs 3 min 13 7 hrs Download Type USB 1 15 minutes or FLASH Memory Card 36 seconds Alarm Type Audio visual High low and low battery conditions Ambient Operating Conditions...

Page 4: ...set the time When the date is set SAVE and press the BACK button to reach the setup menu then HOME button to view the graph 6 You are now ready to begin logging To change any of the preset settings 1...

Page 5: ...the setup menu View There are 3 user selectable views 1 Full Display Graph View 2 Full Display Graph View with Current Temp Temp RH window 3 Large Current Temp Temp RH Display To change View press VI...

Page 6: ...ation 3 pt new units N400 Troubleshooting For troubleshooting information click here for the technical support page Calibration Services New Units N100 NIST Traceable Calibration 1 Point Includes docu...

Page 7: ...eceive the most accurate readings possible How often should I recalibrate my instrumentation Depending on the environment your instrument is used in and how often it is handled you will want to recali...

Page 8: ...bel the outside of the box with the RA and return the instrument freight pre paid to Dickson All instruments that do not have the RA clearly marked on the outside of the box will be refused When retur...

Reviews: