Firmware Command Groups and Parameters
A-5
!Done
or
!Error
Note: The new stop bits setting takes effect after the host computer receives the !Done
response from the reader. All subsequent communications will be at the new stop bits
setting.
Parity Select
!102x
where x = 0 to 2
0
=
disable parity
(factory setting)
1
=
enable even parity
2
=
enable odd parity
Response
!Done
or
!Error
Note: The new parity select setting takes effect after the host computer receives the
!Done response from the reader. All subsequent communications will be at the new
parity setting.
Command Group 2 — Real-Time Clock Control
Group 2 commands control the real-time clock, which maintains the time and date.
The user can set or display the time and date using Group 2 commands.
The real-time clock is supported by an internal lithium battery so that time and date
are preserved in case of power outage. The minimum life expectancy of the battery is
five years, and the battery has a typical life expectancy of 19 years.
Set the Time in the Real-time Clock
!20hh:mm:ss
where
hh = hours (00-23)
mm = minutes (00-59)
ss
= seconds (00-59)
Note: Enter the time exactly as shown with no spaces between characters. All entries
use decimal characters 0 through 9.
Summary of Contents for AI1401
Page 2: ......
Page 5: ...Contents...
Page 6: ......
Page 9: ...1 Before You Begin...
Page 10: ......
Page 13: ...2 Overview...
Page 14: ......
Page 20: ...AI1401 Reader User Guide 2 8...
Page 21: ...3 AI1401 Reader Interface Capabilities...
Page 22: ......
Page 27: ...A Firmware Command Groups and Parameters...
Page 28: ......
Page 39: ...B AI1401 Character Conversion...
Page 40: ......
Page 42: ...AI1401 Reader User Guide B 4...