background image

The two active pairs in an
ATM network are pins 1 & 2
and pins 7 & 8. Use only
dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange)
for the active pins.

1. Is the power LED on the media converter illuminated?

NO

Is the Slide-In-Module properly connected to the Media Conversion Center
chasis backplane?

Is the Power Supply Module properly connected both to the Media Conversion
Center chasis backplane and to the AC outlet? 

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the Copper Activity LED illuminated?

NO

Check UTP cables for proper connection and pin assignment.  (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the Fiber Activity LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX
ports, respectively, on the other 100BASE-FX device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

KEEP twisted-pair RUNS AS SHORT AS POSSIBLE.

Install no more than two (2) media converters in series.

Troubleshooting the Media Converter 

Installation Notes

If the ATM media converter fails, determine the answers to the following questions:

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

1

2

7

8

1

2

7

8

1

2

7

8

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices

1

2

7

8

Be certain that the twisted-pair cable is configured correctly (straight through
or crossover) for site
. Cable connections between an ATM switch and the
media converter must be configured as straight through. Cable connections
between the media converter and a NIC must be configured as crossover.

The physical characteristics of the media cable must meet or exceed the
specifications: ATM UNI 3.1 #AF-PHY-0015
Maximum number of media converters in series: 

2

ATM Cable Specifications

Fiber Cable Specifications

Singlemode
Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -15.0 

dBm

max: -8.0 

dBm

Fiber Optic Receiver Sensitivity:

min: -31.0

dBm

max: -8.0 

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

20 kilometers

multimode
Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 

dBm

max: -14.0 

dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 

dBm

max: -14.0 

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

2 kilometers

Copper Cable Specifications

Category 5 wire or better is required. Either shielded twisted-pair (STP) or
unshielded twisted-pair (UTP) can be used.

Category 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Impedance 100 

±10% @ 10 MHz 

Maximum Cable Distance:

100 meters (330 feet)

C/A-CF-02

Installing Slide-In-Module(s)

CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when installing Media Converter Slide-in-Module(s) in the 16-Slot Media Conversion
Center. Failure to observe this caution could result in damage to, and subsequent
failure of, the Media Converter Slide-in-Module(s).

NOTE: Slide-in-Modules can be installed in any installation slot, in any order.

To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:

1. Remove Media Converter Slide-in-Module protective plate from selected installation

slot by removing two screws that secure plate to front of E-MCC-1600. Retain one
installation screw.

2. Carefully slide Media Converter Slide-in-Module into installation slot, aligning

Media Converter Slide-in-Module with installation guides.

NOTE: Ensure that the Media Converter Slide-in-Module is seated firmly against the
backplane.

3. Secure Slide-in-Module by installing retained installation screw.