background image

C/E-PSW-FX-03 IN THE NETWORK

The TRANSITION Networks C/E-PSW-FX-03 series two-port bridging
media converter is intended to be installed, singly or in pairs, to provide
network distance extension, network congestion reduction, and/or rate
conversion between legacy Ethernet

and Fast Ethernet devices.

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Case Dimensions

4.75" x 3.0" x 1.0"

(119mm x 76mm x 25mm)

Shipping Weight

2 pounds

(0.9 kilograms)

Environment

Temperature:

0-50°C (32° to 122° F )

Storage Temperature:  -20 to 85°C

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

C/E-PSW-FX-03 Series Bridging Media Converter 

Part Number:

C/E-PSW-FX-03, C/E-PSW-FX-03(SC), C/E-PSW-FX-03(SM),
C/E-PSW-FX-03(LH), C/E-PSW-FX-03(LW), C/E-PSW-FX-03(XL)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the E-PSW-FX-03 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_September 10, 2000_____

Stephen Anderson, Vice-President of Engineering

Date

Link

UTP/STP

Fiber

Link

FDX

Power

100

Link

UTP/STP

Fiber

Link

FDX

Power

100

10BASE-T Cable

100BASE-TX Cable

1

00

BA

SE-FX

Ca

ble

Summary of Contents for C/E-PSW-FX-03

Page 1: ...nkstörungen auftreten in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de créer des interférences radioélectriques il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées Trademark Notice All registered trademarks and trademarks are the property o...

Page 2: ...n Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C E PSW FX 03 Series Bridging Media Converter Part Number C E PSW FX 03 C E PSW FX 03 SC C E PSW FX 03 SM C E PSW FX 03 LH C E PSW FX 03 LW C E PSW FX 03 XL Regulation EMC Directive 89 336 EEC Purpose To declare that the E PSW FX 03 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class...

Page 3: ...P If the receiving switch is capable of 10BASE T communication only the FLPs are ignored and the cable segment operates as 10BASE T If the device can support 100BASE TX operation the bridging media converter detects the FLPs uses the auto negotiation algorithm and FLP data to determine the highest possible cable segment speed and mode and automatically places both the device and the bridging media...

Page 4: ...for a later upgrade to 100BASE TX DO NOT USE FLAT OR SILVER SATIN WIRE 100BASE TX The physical characteristics of 100BASE TX cable must meet or exceed IEEE 802 3 100BASE TX specifications Category 5 cable or better is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz ...

Page 5: ...connect the fiber cable to restart the initialization process Restart the terminal device s to restart the initialization process Refer to Tech Tips available at http www transition com Contact Technical Support 800 260 1312 YES Contact Technical Support 800 260 1312 TWISTED PAIR AUTO NEGOTIATION Set auto negotiation DIP switch 1 to select auto negotiation ON UP Set twisted pair full duplex half d...

Page 6: ...Slide in Module into installation slot aligning Media Converter Slide in Module with installation guides NOTE Ensure that the Media Converter Slide in Module is seated firmly against the backplane 3 Secure Slide in Module to E MCC 1600 chassis by rotating captive screw attached to Slide in Module clockwise into chassis OPERATION Use the status indicator LEDs to monitor C E PSW FX 03 operation in t...

Page 7: ...ound arrow 3 Connect other end of cable installed at transmit TX connector of bridging media converter to receive RX connector on network device connect other end of cable installed at receive RX connector of bridging media converter to transmit TX connector on network device Powering the Bridging Media Converter NOTE The Slide In Module is powered through the Media Conversion Center Using the 5 S...

Page 8: ...T AND THE ETHERNET COLLISION DOMAIN Refer to the 5 Segment Rule page 8 before installing half duplex 10BASE T cable Installing full duplex twisted pair cable avoids collision domain considerations distances remain 100 meters 100BASE TX AND THE FAST ETHERNET COLLISION DOMAIN Refer to the 512 Bit Rule before installing half duplex 100BASE TX cable Installing full duplex twisted pair cable avoids col...

Page 9: ......

Reviews: