FAULT ISOLATION and CORRECTION

If a bridging media converter fails, ask the following questions and then
taking the indicated action:

1.

Is the P(o)W(e)R LED on the C/E-PSW-FX-03 illuminated?
NO

Is the power adapter the proper type of voltage and cycle
frequency for the AC outlet?  

Is the power adapter properly installed in the media
converter and in the 

grounded AC 

outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Continue at step 2.

2.

Is the Link LED illuminated on a port with twisted-pair installed?
NO

Check UTP cables for proper connection/pin assignment. 

Ensure that terminal device(s) is/are powered.

Disconnect and reconnect the copper cable to restart the
initialization process.

Restart the terminal device(s) to restart the initialization process.

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 3.

3.

Is the Link LED illuminated on a port with fiber installed?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables are connected to RX and TX ports,
respectively, on 100BASE-FX device.

Ensure that terminal device(s) is/are powered.

Disconnect and reconnect the fiber cable to restart the initialization
process.

Restart the terminal device(s) to restart the initialization process.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support: (800) 260-1312.

YES

Contact Technical Support: (800) 260-1312.

TWISTED-PAIR AUTO-NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-negotiation:

ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2)
to select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3)
to select 100BASE-TX: ON=UP

TWISTED-PAIR FULL-DUPLEX 100BASE-TX:

Set auto-negotiation (DIP switch #1) to de-select auto-negotiation:

OFF=DOWN

Set twisted-pair full-duplex/half-duplex (DIP switch #2)
to select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3)
to select 100BASE-TX: ON=UP

TWISTED-PAIR 10BASE-T WITH MODE AUTO-

NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-
negotiation: ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2)
to select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3)
to select 10BASE-T: OFF=DOWN

FIBER FULL-DUPLEX 100BASE-FX:

Set fiber full-duplex/half-duplex (DIP switch #4) to
select full-duplex: ON=UP

FIBER HALF-DUPLEX 100BASE-FX:

Set fiber full-duplex/half-duplex (DIP switch #4) to
select half-duplex: OFF=DOWN

UP UP UP

DOWN

UP UP

UP

UP

DOWN

UP

DOWN

Summary of Contents for C/E-PSW-FX-03

Page 1: ...nkstörungen auftreten in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de créer des interférences radioélectriques il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées Trademark Notice All registered trademarks and trademarks are the property o...

Page 2: ...n Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C E PSW FX 03 Series Bridging Media Converter Part Number C E PSW FX 03 C E PSW FX 03 SC C E PSW FX 03 SM C E PSW FX 03 LH C E PSW FX 03 LW C E PSW FX 03 XL Regulation EMC Directive 89 336 EEC Purpose To declare that the E PSW FX 03 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class...

Page 3: ...P If the receiving switch is capable of 10BASE T communication only the FLPs are ignored and the cable segment operates as 10BASE T If the device can support 100BASE TX operation the bridging media converter detects the FLPs uses the auto negotiation algorithm and FLP data to determine the highest possible cable segment speed and mode and automatically places both the device and the bridging media...

Page 4: ...for a later upgrade to 100BASE TX DO NOT USE FLAT OR SILVER SATIN WIRE 100BASE TX The physical characteristics of 100BASE TX cable must meet or exceed IEEE 802 3 100BASE TX specifications Category 5 cable or better is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz ...

Page 5: ...connect the fiber cable to restart the initialization process Restart the terminal device s to restart the initialization process Refer to Tech Tips available at http www transition com Contact Technical Support 800 260 1312 YES Contact Technical Support 800 260 1312 TWISTED PAIR AUTO NEGOTIATION Set auto negotiation DIP switch 1 to select auto negotiation ON UP Set twisted pair full duplex half d...

Page 6: ...Slide in Module into installation slot aligning Media Converter Slide in Module with installation guides NOTE Ensure that the Media Converter Slide in Module is seated firmly against the backplane 3 Secure Slide in Module to E MCC 1600 chassis by rotating captive screw attached to Slide in Module clockwise into chassis OPERATION Use the status indicator LEDs to monitor C E PSW FX 03 operation in t...

Page 7: ...ound arrow 3 Connect other end of cable installed at transmit TX connector of bridging media converter to receive RX connector on network device connect other end of cable installed at receive RX connector of bridging media converter to transmit TX connector on network device Powering the Bridging Media Converter NOTE The Slide In Module is powered through the Media Conversion Center Using the 5 S...

Page 8: ...T AND THE ETHERNET COLLISION DOMAIN Refer to the 5 Segment Rule page 8 before installing half duplex 10BASE T cable Installing full duplex twisted pair cable avoids collision domain considerations distances remain 100 meters 100BASE TX AND THE FAST ETHERNET COLLISION DOMAIN Refer to the 512 Bit Rule before installing half duplex 100BASE TX cable Installing full duplex twisted pair cable avoids col...

Page 9: ......

Reviews: