background image

C/E-TX-SX-02 IN THE NETWORK

The C/E-TX-SX-02 media converter is designed to work effectively with
10/100 autonegotiating ports to provide reliable 10 Mbps or 100 Mbps
fiber links. 
The C/E-TX-SX-02 receives and transmits network signals in either full-
duplex or half-duplex mode, depending upon the network devices to
which the media converter is attached. Fast Ethernet

in full-duplex

mode allows the maximum cable distances shown on these pages. Fast
Ethernet

in half-duplex mode requires attention to the 512-bit Rule

(See page 4).
NOTE: Both copper AND fiber connections to the C/E-TX-SX-02 must
be at the same media-speed: 10BASE-T / 10BASE-FL or 100BASE-TX /
100BASE-SX OR one or both connections must be capable of auto-
negotiation.

Network Installation 

Install two C/E-TX-SX-02 series media converters in series to extend,
over fiber, the distance between two 10BASE-T or 100BASE-TX devices: 

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3, 
Compliant with pending TIA/EIA-785 specification 

Environment

Temperature:

0-40°C (32° to 104° F )

Storage Temperature: -15° to 65°C (5° to 149° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

C/E-TX-SX-02 Series Media Converters

Part Number(s):

C/E-TX-SX-02, C/E-TX-SX-02(SC)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the C/E-TX-SX-02 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_November 1, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

 UTP/STP

Fiber

up to 300 meters - multimode

up to 100 meters 

up to 100 meters 

Summary of Contents for C/E-TX-SX-02

Page 1: ...rs etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A...

Page 2: ...ance between two 10BASE T or 100BASE TX devices TECHNICAL SPECIFICATIONS Standards IEEE 802 3 Compliant with pending TIA EIA 785 specification Environment Temperature 0 40 C 32 to 104 F Storage Temperature 15 to 65 C 5 to 149 F Humidity 10 90 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344...

Page 3: ...TEGORY 5 Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Maximum Cable Distance 100 meters RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Twisted pair connection requires two active pairs configured as straight through and or crossover The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange f...

Page 4: ...ity LED illuminated NO If there is no activity on the 10 100BASE TX port proceed to step 7 If there is activity on the 10 100BASE TX port disconnect and reconnect the 10 100BASE TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 800 260 1312 YES Proceed to step 7 7 Is the 10 100SX ACT ivity LED illuminated NO If th...

Page 5: ...ISTENT disconnect and reconnect either cable to restart the initialization process If the fault is not corrected proceed to step 6 INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Converter Slide in Module protective plate from selected installation slot by removing screw that secure...

Page 6: ...used when connecting to 10BASE T or to 100BASE TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires no operator intervention Using Autonegotiation The C E TX SX 02 series media converter Autonegotiation feature allows the m...