C/E-TX-SX-02 IN THE NETWORK

(continued)

Media Converter in Full-Duplex Network

In a full-duplex network, maximum cable lengths are determined by the
cables used. See page 10 for cable specifications. 

NOTE: The 512-Bit Rule described below does NOT apply in a full-duplex
network.

Media Converter in Half-Duplex Network

The 512-Bit Rule applies separately to each collision domain.

USING THE 512-BIT RULE

In a half-duplex network, maximum cable lengths are determined by the
round trip delay limitations of each Fast Ethernet

collision domain.

(Switches and routers divide the network into separate Ethernet™ collision
domains.) The 512-Bit Rule determines maximum distances by calculating
the collision domain round-trip delay in bit-times. 

To calculate a collision domain
round-trip delay in bit-times, find the
longest path between any two
terminal devices in the collision
domain. Calculate the round trip
delay by multiplying the length of the
cable (in meters) by the delay per
meter (in bit-times (BT)), then take the

sum of all cable delays plus station (DTE), repeater, and media converter
delays. If the result is less than or equal to 512 bit-times, the path is good. 

YES - QUICKLY

The media converter has selected 100 Mb/s operation. If this is NOT
the correct speed, disconnect and reconnect the 10/100BASE-TX
cable to restart the initialization process. If the fault is not corrected,
proceed to step 6.

6.

Is the 10/100TX ACT(ivity) LED illuminated?
NO

If there is no activity on the 10/100BASE-TX port, proceed to step 7.

If there is activity on the 10/100BASE-TX port, disconnect and
reconnect the 10/100BASE-TX cable to restart the initialization
process.

Restart the workstation to restart the initialization process.

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 7.

7.

Is the 10/100SX ACT(ivity) LED illuminated?
NO

If there is no activity on the 10/100BASE-SX port, continue below

If there is activity on the 10/100BASE-SX port, disconnect and
reconnect the 10/100BASE-SX cable to restart the initialization
process.

Restart the workstation to restart the initialization process.

Contact Technical Support: (800) 260-1312.

YES

Contact Technical Support: (800) 260-1312.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.

Class I repeater

140 BT

Class II repeater

92 BT

DTE (PC, switch, router)

50 BT

C/E-TX-SX-02 12 

BT

1 meter CAT.5 TP cable

1.11 BT

1 meter fiber cable

1 BT

Fast Ethernet switch

50 BT

10 meters TP 

@ 1.11BT/meter 

= 11.1BT

10 meters TP 

@ 1.11BT/meter 

= 11.1BT

E-TX-SX-02

= 12BT

DTE= 50BT

Half-Duplex Collision Domain

Half-Duplex Collision Domain

200 meters fiber 

@ 1.0 BT/meter 

= 200BT

DTE= 50BT

50.00BT

+11.10BT

+12.00BT

+200.00BT

+12.00BT

+11.10BT

+50.00BT

__________

_

= 346.20BT

DTE= 50BT

10 meters TP 

@ 1.11BT/meter 

= 11.1BT

150 meters fiber 

@ 1.0 BT/meter 

= 150BT

10 meters TP 

@ 1.11BT/meter 

= 11.1BT

Class I

Hub

= 140BT

50.00BT

+11.10BT

+140.00BT

+150.00BT

+12.00BT

+11.10BT

+50.00BT

__________

_

= 424.20BT

Switch/

Router

= 50BT

E-TX-SX-02

= 12BT

Full-Duplex - NO Collision Domain

E-TX-SX-02

= 12BT

E-TX-SX-02

= 12BT

Summary of Contents for C/E-TX-SX-02

Page 1: ...rs etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A...

Page 2: ...ance between two 10BASE T or 100BASE TX devices TECHNICAL SPECIFICATIONS Standards IEEE 802 3 Compliant with pending TIA EIA 785 specification Environment Temperature 0 40 C 32 to 104 F Storage Temperature 15 to 65 C 5 to 149 F Humidity 10 90 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344...

Page 3: ...TEGORY 5 Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Maximum Cable Distance 100 meters RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Twisted pair connection requires two active pairs configured as straight through and or crossover The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange f...

Page 4: ...ity LED illuminated NO If there is no activity on the 10 100BASE TX port proceed to step 7 If there is activity on the 10 100BASE TX port disconnect and reconnect the 10 100BASE TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 800 260 1312 YES Proceed to step 7 7 Is the 10 100SX ACT ivity LED illuminated NO If th...

Page 5: ...ISTENT disconnect and reconnect either cable to restart the initialization process If the fault is not corrected proceed to step 6 INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Converter Slide in Module protective plate from selected installation slot by removing screw that secure...

Page 6: ...used when connecting to 10BASE T or to 100BASE TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires no operator intervention Using Autonegotiation The C E TX SX 02 series media converter Autonegotiation feature allows the m...