background image

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:

1.

Is the P(o)W(e)R LED on the media converter illuminated?
NO

Is the power cord properly installed in the media converter and in
the grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 2.

2.

Does the 10/100TX STAT(us) LED blink ONCE and then go off?
YES

Check twisted pair cables for proper connection.

Contact Technical Support: (800) 260-1312.

NO

Proceed to step 3.

3.

Does the 10/100FX STAT(us) LED blink FIVE TIMES and then go
off?
YES

10Mb/s: Receive Pair has wrong polarity.

100Mb/s: Proceed to step 4.

NO

Proceed to step 4.

4.

Does the 10/100SX STAT(us) LED blink ONCE and then go off?
YES

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.

Contact Technical Support: (800) 260-1312.

NO

Proceed to step 5.

5.

Is the 100 LED blinking?
NO

The media converter has selected 10 Mb/s operation. If this is NOT
the correct speed, disconnect and reconnect the 10/100BASE-TX
cable to restart the initialization process. If the fault is not corrected,
proceed to step 6.

YES - SLOWLY

The media converter is selecting between 10 Mb/s and 100 Mb/s
speed OR one or both of the links is down. IF PERSISTENT,
disconnect and reconnect either cable to restart the initialization
process. If the fault is not corrected, proceed to step 6.

INSTALLATION 

Install Slide-In-Module in E-MCC-1600 Chassis

NOTE: Media Converter Slide-in-Modules can be installed in any installation
slot, in any order.

Remove Media Converter Slide-in-Module protective plate from selected
installation slot by removing screw that secures plate to front of E-MCC-
1600 chassis. 

Carefully slide Media Converter Slide-in-Module into installation slot,
aligning Media Converter Slide-in-Module with installation guides.

NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated
against the backplane.

Secure Slide-in-Module by securing panel fastener screw attached to
Slide-in-Module to E-MCC-1600 chassis.

Install Cable

COPPER

NOTE: AutoCross™ allows the use of either straight-through or crossover
configuration cables.

1.

Locate or build 10BASE-T-compliant or 100BASE-TX-compliant
cables with male RJ-45 connectors installed at both ends.

2.

Connect RJ-45 connector at one end of cable to media converter
RJ-45 port connector.

3.

Connect RJ-45 connector at other end of cable to 10BASE-T-
compliant or 100BASE-TX-compliant device RJ-45 port
connector.

FIBER

1.

Locate or build 10/100BASE-SX-compliant fiber cable with male
two-stranded TX to RX connectors installed at both ends.

2.

Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on media converter.

3.

Connect male TX and RX cable connectors at other end of cable to
10/100BASE-SX-compliant device RX and TX connectors,
respectively.

TX

RX

TX

RX

Summary of Contents for C/E-TX-SX-02

Page 1: ...rs etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A...

Page 2: ...ance between two 10BASE T or 100BASE TX devices TECHNICAL SPECIFICATIONS Standards IEEE 802 3 Compliant with pending TIA EIA 785 specification Environment Temperature 0 40 C 32 to 104 F Storage Temperature 15 to 65 C 5 to 149 F Humidity 10 90 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344...

Page 3: ...TEGORY 5 Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Maximum Cable Distance 100 meters RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Twisted pair connection requires two active pairs configured as straight through and or crossover The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange f...

Page 4: ...ity LED illuminated NO If there is no activity on the 10 100BASE TX port proceed to step 7 If there is activity on the 10 100BASE TX port disconnect and reconnect the 10 100BASE TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 800 260 1312 YES Proceed to step 7 7 Is the 10 100SX ACT ivity LED illuminated NO If th...

Page 5: ...ISTENT disconnect and reconnect either cable to restart the initialization process If the fault is not corrected proceed to step 6 INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Converter Slide in Module protective plate from selected installation slot by removing screw that secure...

Page 6: ...used when connecting to 10BASE T or to 100BASE TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires no operator intervention Using Autonegotiation The C E TX SX 02 series media converter Autonegotiation feature allows the m...