background image

OPERATION 

Using Status LEDs

Use the status LEDs to monitor media converter operation in the network. 

100

Steady LED indicates 100 Mb/s
operation.

One (1) continuous, slowly flashing
blink indicates

speed selection in

progress.

One (1) continuous, quickly flashing
blink indicates 100 Mb/s operation

.

Po(W)e(R)

Steady LED indicates connection to
external AC power.

STAT(us)

(10/100TX)  Steady LED indicates
normal operation.

One (1) continuous, flashing blink
indicates Link Down.

Five (5) continuous, flashing blinks
when the selected speed is 10 Mb/s
indicates that the receive pair has the
wrong polarity; five (5) continuous,
flashing blinks when the selected
speed is 100 Mb/s should be ignored.

ACT(ivity)

(10/100TX) Flashing LED indicates
10/100BASE-TX activity.

STAT(us)

(10/100SX)  Steady LED indicates normal operation.

One (1) continuous, flashing blink indicates

Link Down.

ACT(ivity)

(10/100SX)  Flashing LED indicates 10/

100BASE-SX activity.

Using AutoCross

*

The AutoCross™ feature allows either straight-through (MDI) or crossover
(MDI-X) cables to be used when connecting to 10BASE-T or to 100BASE-TX
devices, such as hubs, transceivers, or network interface cards (NICs).
AutoCross™ determines the characteristics of the cable connection and
automatically configures the unit to link up, regardless of the cable
configuration. 

*Requires no operator intervention.

Using Autonegotiation*

The C/E-TX-SX-02 series media converter Autonegotiation feature allows the
media converter to be used with 10BASE-T, 100BASE-TX, 10BASE-FL and
100BASE-SX ports. 

The media converter will bring up the link in the highest speed and mode
possible between the station and the device. 

*Requires no operator intervention.

Using LinkAlert™

The C/E-TX-SX-02 series media converter LinkAlert™ feature allows the
media converter to pass 10/100BASE-TX-side link faults over the link to the
10/100BASE-SX side and to pass 10/100BASE-SX-side link faults over the link
to the 10/100BASE-TX side.

If the C/E-TX-SX-02 media converter does not detect a good link on the 
10/100BASE-TX side, the C/E-TX-SX-02 disables all transmission (including
active-idle) on the 10/100BASE-SX side. 

10/100BASE-TX

Device

Media Converter

LINK FAULT INDICATION

10/100BASE-SX

Device

10BASE-T

RX

TX

10/100TX

10/100SX

STAT

ACT

STAT

ACT

100

PWR

Summary of Contents for C/E-TX-SX-02

Page 1: ...rs etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A...

Page 2: ...ance between two 10BASE T or 100BASE TX devices TECHNICAL SPECIFICATIONS Standards IEEE 802 3 Compliant with pending TIA EIA 785 specification Environment Temperature 0 40 C 32 to 104 F Storage Temperature 15 to 65 C 5 to 149 F Humidity 10 90 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344...

Page 3: ...TEGORY 5 Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Maximum Cable Distance 100 meters RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Twisted pair connection requires two active pairs configured as straight through and or crossover The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange f...

Page 4: ...ity LED illuminated NO If there is no activity on the 10 100BASE TX port proceed to step 7 If there is activity on the 10 100BASE TX port disconnect and reconnect the 10 100BASE TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 800 260 1312 YES Proceed to step 7 7 Is the 10 100SX ACT ivity LED illuminated NO If th...

Page 5: ...ISTENT disconnect and reconnect either cable to restart the initialization process If the fault is not corrected proceed to step 6 INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Converter Slide in Module protective plate from selected installation slot by removing screw that secure...

Page 6: ...used when connecting to 10BASE T or to 100BASE TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires no operator intervention Using Autonegotiation The C E TX SX 02 series media converter Autonegotiation feature allows the m...