CPSMP-200

2

Tech Support:  

1-800-260-1312

-- International:  

00-1-952-941-7600

-- (24 hours)

CAUTION:  Wear a grounding device and observe electrostatic discharge
precautions when installing or servicing the power supply module.  Failure to
observe this caution could result in damage to, and subsequent failure of, the
power supply module.

Installation

The CPSMP-200 AC power supply module may replace an existing AC
module, or it may be installed as the redundant power supply module in
either an AC-powered or a DC-powered 

PointSystem™

chassis.

Switch Settings

The CPSMP-200 power supply module has a set of 

Primary/Secondary-

Management/Manual

switches installed on the circuit board.  

Management/Manual Switch

The Management/Manual switch allows the 

PointSystem™

software to control

and override the physical setting on the Primary/Secondary switch.  

When set to 

‘Management’

, the power supply module has the default

configuration of ‘Primary’, unless changed at the software interface to
‘Secondary’.

When set to 

‘Manual’

, the power supply module has the configuration as

set by the Primary/Secondary switch.  The software interface cannot
change the setting.  

I
0

Manual

Management

Secondary

Primary

techsupport@transition.com

-- Click the 

“Transition Now”

link for a live Web chat.

3

Primary/Secondary Switch

The 

Primary/Secondary

switch allows the module to be configured as the

‘Primary’ or as the ‘Secondary’ power supply.  

As the 

‘Primary’

power supply, it provides power to the entire chassis.  

As the 

‘Secondary’

power supply, it waits in stand-by mode, ready to

supply power to the chassis in the event of power failure from the
‘Primary’ power supply.

Configuring Two Power Supply Modules

For 

load sharing

, where each module supplies power to half the chassis,

set both power supply modules to ‘Primary’.  

For 

back-up power supply

, set one power supply module to ‘Primary’

(which supplies power to the entire chassis) and the other to ‘Secondary’.
In this mode, the secondary module is in stand-by mode and takes over
in the event of a power failure of the primary module.

NOTE:  

At least one power supply module must be set to ‘Primary.’ If

both modules are set to ‘Secondary,’ neither will supply power to the
chassis.

I
0

Manual

Management

Secondary

Primary

Summary of Contents for CPSMP-200

Page 1: ...tch that when set to I allows the module to supply power to the PointSystem chassis A Primary Secondary switch that allows the module to be configured as the primary or as the secondary power supply A Management Manual switch that allows the PointSystem software to control and override the physical setting of the Primary Secondary switch A fan to cool the interior of the PointSystem chassis A hand...

Page 2: ...e power supply module has the configuration as set by the Primary Secondary switch The software interface cannot change the setting I 0 Manual Management Secondary Primary techsupport transition com Click the Transition Now link for a live Web chat 3 Primary Secondary Switch The Primary Secondary switch allows the module to be configured as the Primary or as the Secondary power supply As the Prima...

Page 3: ...ly module into the installation slot aligning the module with the installation guides Ensure that the power supply module is firmly seated against the chassis backplane 5 Carefully install the two 2 screws retained in step 1 through the power supply module and into the chassis Rotate the screws clockwise to secure I 0 I 0 I 0 Primary Secondary Switch and Management Manual Switch techsupport transi...

Page 4: ...2 screws that secure the power supply module to the chassis Retain the screws for installing the replacement module 4 Carefully slide the power supply module out of the chassis I 0 On Off Switch AC Power Cord I 0 I 0 techsupport transition com Click the Transition Now link for a live Web chat 7 5 Set the Primary Secondary switch and the Management Manual switch on the replacement power supply modu...

Page 5: ...ion in the power supply module Snap the fuse holder into place 7 See the Connect to External Power section page 5 for instructions on re connecting the power supply module to the external power source I 0 On Off Switch Fuse Holder Fuse techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specification For use with Transition Networks Model CPSMP 200 or equivalen...

Page 6: ...t is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a questi...

Page 7: ... the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inte...

Reviews: