background image

E-MCR-04 

6

Tech Support: 

1-800-260-1312

International: 

00-1-952-941-7600

(24 hours)

Maintenance

Replace the Fuse

1.

Set the On/Off switch to “0”.

2.

Remove the power cord from the AC wall socket.

3.

Insert a small flat blade screwdriver into the groove on the front inside
edge of the fuse holder and carefully pry the fuse holder from the power
supply module. 

4.

Carefully remove the fuse from the fuse holder.

5.

Install the same size and rating replacement fuse into the fuse holder. 

6.

Return the fuse holder and fuse to the installation position in the power
supply module and snap the fuse holder into place. 

7.

Connect the power cord to the external AC outlet.

8.

Set the ON/OFF switch to “I”.

NOTE:

The power LED indicators on the front of the installed media

converters will illuminate when installation is complete.

I

O

1

fuse holder

fuse

techsupport@transition.com

-- Click the 

“Transition Now”

link for a live Web chat.

Declaration of Conformity

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 U.S.A.

Model:

E-MCR-04 Media Converter

Part Number:

E-MCR-04, 

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the

E-MCR-04 to which this declaration refers is in

conformity with the following standards.

EN 55022:1998 A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart B; UL 1950,

EN 61000-3-2:1995+A14:2000; EN61000-3-3:1995

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

July, 2007

Stephen Anderson, Vice-President of Engineering

Date

Technical Specifications

For use with Transition Networks Model E-MCR-04 or equivalent.

Standards:

UL listed, FCC & CISPR Class A; CE Mark

Dimensions: 

17.0" x 15.0" x 5.0"  

(432 mm x 381 mm x 127 mm)

Weight:

8 lbs.  

(3.6 kg)  (approximately)

Power Requirements:

Ensure that the available power circuits are not 
overloaded and that the media converter rack is 
reliably grounded.

Input Voltage:

85 to 264 VAC

Input Frequency:

47 to 63 Hz

Output Voltage:

12 VDC

Output Current:

600 mA per port maximum

Environment:

Tmra* 

0 to 50°C 

(32 to 122°F)

Storage Temp:

-25 to 85°C 

(-13 to 185°F)

Humidity:

10 to 90%, non condensing 

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

*Manufacturer’s rated ambient temperature. 

Compliance Information

UL Listed, C-UL Listed 

(Canada)

, CE Mark

FCC Regulations

This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules.  These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment.  This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.