Install Shelf Support Panel to Media Converter(s) 

The E-MCR-05 comes with 12 self-support panels that must be mounted to each media converter before it can 
be installed. 
1.

 

Set the media converter on its bottom as shown below. 

2.

 

Remove the two (2) screws securing the cover to the media converter. 

3.

 

Position the shelf support panel as shown below. 

4.

 

Insert the two screws as shown below and tighten to secure to the media converter. 

 

Install Media Converters into E-MCR-05 

1.

 

Position the media converter in the E-MCR-05 as shown below and then carefully slide it into the slot. 

2.

 

Tighten the panel fastener located directly under the media converter to secure it to the E-MCR-05. 

 

Summary of Contents for E-MCR-05

Page 1: ...upply Specifications 8 Compliance Information 9 Declaration of Conformity 9 FCC Regulations 9 Canadian Regulations 9 European Regulations 10 Contact Us 10 Warranty 10 Record of Revisions 11 Introduction Transition Networks E MCR 05 series media converter rack provides space and power in a rack mountable chassis for twelve 12 separate and independent Transition Networks stand alone media converters...

Page 2: ...nal installation on a table or other flat stable surface When installing on a table top remove the rubber feet from the card and place them evenly spaced on the bottom of the chassis The E MCR 05 must be installed in a well ventilated area Rack Installation The E MCR 05 ships with four 4 attachment screws for installation in a standard rack Warning Take care to mount the E MCR 05 so that it will n...

Page 3: ...ading weight distribution rack balance 4 Circuit Overloading consider the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Consider all equipment nameplate ratings when addressing this concern 5 Reliable Earthing maintain reliable earthing of rack mounted equipment pay attention to supply connec...

Page 4: ...erter on its bottom as shown below 2 Remove the two 2 screws securing the cover to the media converter 3 Position the shelf support panel as shown below 4 Insert the two screws as shown below and tighten to secure to the media converter Install Media Converters into E MCR 05 1 Position the media converter in the E MCR 05 as shown below and then carefully slide it into the slot 2 Tighten the panel ...

Page 5: ... of 12 Input Power Fuse Label Connect Power to Media Converters 1 Select a barrel connector end of one power supply cable that is inserted into the harness as shown below 2 Insert the octopus power supply cable into the media converter as shown below Cable Assembly 24 Pin to DC Barrel ...

Page 6: ...nd power maximums WARNING Make sure that the E MCR 05 is properly grounded Failure to observe this warning could result in an electrical shock 1 Locate the power cord 2 Insert the female end of the power cord into the power supply AC power inlet shown below 3 Insert the other end of the power cord into the AC wall outlet 4 Press the power ON OFF rocker switch to the ON position to supply power to ...

Page 7: ...Remove the power cord from the power supply of the E MCR 05 3 Insert a small flat blade screwdriver at the fuse holder as shown below and pull or carefully pry outward to dislodge the fuse holder 4 Remove the fuse from the fuse holder 5 Install a new 4A fuse ONLY into the fuse holder 6 Install the fuse holder into E MCR 05 7 Plug the power cord into the E MCR 05 AC power inlet 8 Press the power sw...

Page 8: ...ter rack is reliably grounded Input Voltage 110 to 240VAC Input Current 3 3A maximum 360 watts maximum Input Frequency 50 to 60 Hz Output Voltage 12 VDC Output Current 630 mA per port maximum MTBF 46 000 MIL HDBK 217F Hours 126 500 Bellcore Hours Environment Operating Temp 0 to 50 C 32 to 122 F Humidity 10 to 90 non condensing Altitude 0 10 000 ft Warranty Lifetime Note Information in this documen...

Page 9: ...cordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out...

Page 10: ...27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this document Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526 9267 fax 952...

Page 11: ... a 200 00 charge plus actual shipping costs to and from the customer If the repair is greater than 200 00 an estimate is issued to the customer for authorization of repair If no authorization is obtained or the product is deemed not repairable Transition Networks will retain the 200 00 service charge and return the product to the customer not repaired Non warranted products that are repaired by Tr...

Page 12: ...Transition Networks E MCR 05 User Guide 33392 Rev C https www transition com Page 12 of 12 E MCR 05 Media Converter Rack User Guide 33392 Rev C ...

Reviews: